The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
A Systematic Review of the Safety and Effectiveness of Fast-track Cardiac Anesthesia
Open accessAbstract
Received from the Department of Anaesthesia and Pain Management, Alfred Hospital, Melbourne, Australia.COST containment and efficient resource use have forced anesthesiologists to rethink their management strategies for cardiac surgery. 1–4In the late 1970s, when anesthetic practice predominantly involved inhalational anesthesia, it was possible to extubate cardiac surgical patients within a few hours after surgery. However, there was no economic pressure or incentive to practice cost-effective medicine at that time. An opioid-based anesthetic regimen gained popularity in the 1980s, when studies confirmed its ability to allow hemodynamic stability, even in patients with marginal cardiac reserve. 5,6This necessitated continuation of postoperative ventilatory support for 12–24 h in cardiac surgical patients. The growing need for intensive cardiovascular and ventilatory support during the immediate postoperative period in these patients required an expansion of intensive care unit (ICU) bed availability. Until recently, this need for postoperative ICU nursing care and length of stay had continued unchecked.The aims of “fast-tracking” cardiac surgical patients include early tracheal extubation and decreased length of ICU and hospital stay with subsequent cost reduction. 2–4Fast-track cardiac anesthesia (FTCA) techniques include the use of short-acting hypnotic drugs, reduced doses of opioids, or the use of ultrashort-acting opioids, and, in some cases, the use of antifibrinolytic drugs or drugs to prevent atrial fibrillation.This article is accompanied by an Editorial View. Please see: Wallace AW: Is it time to get on the fast track or stay on the slow track? Anesthesiology 2003; 99:982-987.There are purported benefits of early tracheal extubation and reduced duration of mechanical ventilation. 7Several randomized trials have found that early tracheal extubation can be safely achieved, 8–17and it may lead to reduced ICU stay 10,12and costs. 12,18,19Despite these findings, there are residual concerns regarding early tracheal extubation and FTCA. 20–24Studies to date have not included a sufficient number of patients to detect a clinically important effect on serious morbidity or mortality. The primary objective of this systematic review was to determine whether FTCA is as safe as traditional cardiac anesthesia (TCA) based on the administration of high doses of opioids. The hypothesis tested was that there is not an increased risk of mortality or major morbidity associated with FTCA compared with TCA.This systematic review and meta-analysis followed a protocol that specified the aims, inclusion criteria, anesthetic regimens, and outcome assessments from previously published trials. 25We chose to include all randomized trials of adult cardiac surgical patients undergoing coronary artery bypass graft (CABG) or valve surgery with cardiopulmonary bypass. Patients undergoing off-pump cardiac surgery or having major regional blockade (spinal or epidural techniques) were not included in the analysis. We compared FTCA with TCA. The former group was defined by the use of a reduced dose of opioids (fentanyl, ≤ 20 μg/kg, or equivalent) and the intention to promote early (< 10 h) tracheal extubation. The TCA group was defined by the use of high-dose opioids (fentanyl, > 20 μg/kg).A systematic search for all relevant randomized controlled trials was conducted. 25Relevant trials were obtained from the following sources between August and December 2000: the Cochrane Controlled Trials Register, electronic databases (MEDLINE and EMBASE) 1988–June 2000, and reference lists of relevant studies, reviews, and abstracts in major journals related to anesthesia and cardiac surgery. In addition, the following medical subject headings and text words, and their combinations, were included in a MEDLINE electronic search strategy with the assistance of a librarian:anesthesia , coronary artery bypass surgery , postoperative complications , heart , fast-track , fast-tracking , early extubation , tracheal extubation , ventilation , intensive care , morbidity , and mortality . No language restrictions were applied.The quality of eligible trials was assessed independently, under open conditions. 25,26Masking, losses to follow-up, method of randomization, sample size, and power calculations were recorded. The patient population, type of surgery, and anesthetic details were also collected. Data from the trial reports were independently checked by two or more investigators; disagreements were resolved by consensus. In cases in which relevant data were not presented in the original publication, the primary author was contacted by letter, and information on additional unpublished data was requested.Our primary outcome was 30-day all-cause mortality. Secondary outcomes were major morbidities and included the following:myocardial infarction (i.e. , new Q waves on two adjacent leads of a 12-lead electrocardiogram); major sepsis (i.e. , patient temperature
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Funnel plots for detecting bias in meta-analysis
Sterne, J. A. C., & Egger, M. (2001) · Journal of Clinical Epidemiology · doi:10.1016/s0895-4356(01)00377-8 · Cited by 3,779
The Hazards of Scoring the Quality of Clinical Trials for Meta-analysis
Jüni, P. (1999) · JAMA · doi:10.1001/jama.282.11.1054 · Cited by 1,981
Understanding research synthesis (meta-analysis).
Mosteller, F., & Colditz, G. A. (1996) · Annual Review of Public Health · doi:10.1146/annurev.pu.17.050196.000245 · Cited by 228
Cited by
2021 ACC/AHA/SCAI Guideline for Coronary Artery Revascularization
Lawton, J. S., Tamis-Holland, J. E., Bangalore, S., Bates, E. R., Beckie, T. M., Bischoff, J. M., Bittl, J. A., Cohen, M. G., DiMaio, J. M., Don, C. W., et al. (2022) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2021.09.006 · Cited by 1,558
Lawton, J. S., Tamis-Holland, J. E., Bangalore, S., Bates, E. R., Beckie, T. M., Bischoff, J. M., Bittl, J. A., Cohen, M. G., DiMaio, J. M., Don, C. W., et al. (2022) · Circulation · doi:10.1161/cir.0000000000001038 · Cited by 829
2011 ACCF/AHA Guideline for Coronary Artery Bypass Graft Surgery
Hillis, L. D., Smith, P. K., Anderson, J. L., Bittl, J. A., Bridges, C. R., Byrne, J. G., Cigarroa, J. E., DiSesa, V. J., Hiratzka, L. F., Hutter, A. M., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.08.009 · Cited by 820
Writing Committee Members, Hillis, L. D., Smith, P. K., Anderson, J. L., Bittl, J. A., Bridges, C. R., Byrne, J. G., Cigarroa, J. E., DiSesa, V. J., Hiratzka, L. F., et al. (2011) · Circulation · doi:10.1161/cir.0b013e31823c074e · Cited by 781
Writing Committee Members, Hillis, L. D., Smith, P. K., Anderson, J. L., Bittl, J. A., Bridges, C. R., Byrne, J. G., Cigarroa, J. E., DiSesa, V. J., Hiratzka, L. F., et al. (2011) · Circulation · doi:10.1161/cir.0b013e31823b5fee · Cited by 614
Metadata
- Authors
- Warltier, D. C., Myles, P. S., Daly, D. J., Djaiani, G., Lee, A., & Cheng, D. C. H.
- Venue
- Anesthesiology
- Published
- 2003-10-01
- Volume
- 99
- Issue
- 4
- Pages
- 982-987
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W2076192647
- Cited by
- 246
- References
- 3
- FWCI
- 1.43
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Systematic Review of the Safety and Effectiveness of Fast-track Cardiac Anesthesia. https://app.cochat.ai/papers/10.1097/00000542-200310000-00035
- The paper
- Warltier, D. C., Myles, P. S., Daly, D. J., Djaiani, G., Lee, A., & Cheng, D. C. H. (2003). A Systematic Review of the Safety and Effectiveness of Fast-track Cardiac Anesthesia. Anesthesiology. https://doi.org/10.1097/00000542-200310000-00035
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.