CoChat

ED50and ED95of Intrathecal Hyperbaric Bupivacaine Coadministered with Opioids for Cesarean Delivery

Open access
Ginosar, Yehuda, Mirikatani, Edward, Drover, David R., Cohen, Sheila E., Riley, Edward T. · 2004 · Anesthesiology
Cited by 181

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Background: Successful cesarean delivery anesthesia has been reported with use of small doses (5-9 mg) of intrathecal bupivacaine coadministered with opioids. This double-blind, randomized, dose-ranging study determined the ED50 and ED95 of intrathecal bupivacaine (with adjuvant opioids) for cesarean delivery anesthesia. Methods: Forty-two parturients undergoing elective cesarean delivery with use of combined spinal-epidural anesthesia received intrathecal hyperbaric bupivacaine in doses of 6, 7, 8, 9, 10, 11, or 12 mg in equal volumes with an added 10 microg intrathecal fentanyl and 200 microg intrathecal morphine. Sensory levels (pinprick) were evaluated every 2 min until a T6 level was achieved. The dose was a success(induction) if a bilateral T6 block occurred in 10 min; otherwise, it was a failure(induction). In addition to being a success(induction), the dose was a success(operation) if no intraoperative epidural supplement was required; otherwise, it was a failure(operation). ED50 and ED95 for both success(induction) and success(operation) were determined with use of a logistic regression model. Results: ED50 for success(induction) and success(operation) were 6.7 and 7.6 mg, respectively, whereas the ED95 for success(induction) and success(operation) were 11.0 and 11.2 mg. Speed of onset correlated inversely with dose. Although no clear advantage for low doses could be demonstrated (hypotension, nausea, vomiting, pruritus, or maternal satisfaction), this study was underpowered to detect significance in these variables. Conclusions: The ED95 of intrathecal bupivacaine under the conditions of this study is considerably in excess of the low doses proposed for cesarean delivery in some recent publications. When doses of intrathecal bupivacaine less than the ED95, particularly near the ED50, are used, the doses should be administered as part of a catheter-based technique.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00000542-200403000-00031

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 181

Metadata

Authors
Ginosar, Y., Mirikatani, E., Drover, D. R., Cohen, S. E., & Riley, E. T.
Venue
Anesthesiology
Published
2004-03-01
Volume
100
Issue
3
Pages
676-682
ISSN
0003-3022 (ISSN-L)
OpenAlex
W2063723858
Cited by
181
References
4
FWCI
7.57
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: ED50and ED95of Intrathecal Hyperbaric Bupivacaine Coadministered with Opioids for Cesarean Delivery. https://app.cochat.ai/papers/10.1097/00000542-200403000-00031
The paper
Ginosar, Y., Mirikatani, E., Drover, D. R., Cohen, S. E., & Riley, E. T. (2004). ED50and ED95of Intrathecal Hyperbaric Bupivacaine Coadministered with Opioids for Cesarean Delivery. Anesthesiology. https://doi.org/10.1097/00000542-200403000-00031

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.