ED50and ED95of Intrathecal Hyperbaric Bupivacaine Coadministered with Opioids for Cesarean Delivery
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Background: Successful cesarean delivery anesthesia has been reported with use of small doses (5-9 mg) of intrathecal bupivacaine coadministered with opioids. This double-blind, randomized, dose-ranging study determined the ED50 and ED95 of intrathecal bupivacaine (with adjuvant opioids) for cesarean delivery anesthesia. Methods: Forty-two parturients undergoing elective cesarean delivery with use of combined spinal-epidural anesthesia received intrathecal hyperbaric bupivacaine in doses of 6, 7, 8, 9, 10, 11, or 12 mg in equal volumes with an added 10 microg intrathecal fentanyl and 200 microg intrathecal morphine. Sensory levels (pinprick) were evaluated every 2 min until a T6 level was achieved. The dose was a success(induction) if a bilateral T6 block occurred in 10 min; otherwise, it was a failure(induction). In addition to being a success(induction), the dose was a success(operation) if no intraoperative epidural supplement was required; otherwise, it was a failure(operation). ED50 and ED95 for both success(induction) and success(operation) were determined with use of a logistic regression model. Results: ED50 for success(induction) and success(operation) were 6.7 and 7.6 mg, respectively, whereas the ED95 for success(induction) and success(operation) were 11.0 and 11.2 mg. Speed of onset correlated inversely with dose. Although no clear advantage for low doses could be demonstrated (hypotension, nausea, vomiting, pruritus, or maternal satisfaction), this study was underpowered to detect significance in these variables. Conclusions: The ED95 of intrathecal bupivacaine under the conditions of this study is considerably in excess of the low doses proposed for cesarean delivery in some recent publications. When doses of intrathecal bupivacaine less than the ED95, particularly near the ED50, are used, the doses should be administered as part of a catheter-based technique.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Introduction to Statistical Analysis.
Latshaw, V. V., Dixon, W. J., & Massey, F. J. (1957) · The American Mathematical Monthly · doi:10.2307/2309989 · Cited by 5,072
Morgan, P. J., Halpern, S. H., & Tarshis, J. (2001) · Anesthesia & Analgesia · doi:10.1097/00000539-200104000-00036 · Cited by 164
INFLUENCE OF OBESITY ON SPINAL ANALGESIA WITH ISOBARIC 0.5% BUPIVACAINE
McCULLOCH, W. J., & Littlewood, D. G. (1986) · British Journal of Anaesthesia · doi:10.1093/bja/58.6.610 · Cited by 106 · cited 1×
“McCulloch also showed an increased level of block in obese patients undergoing urologic procedures.(8) In contrast, Hartwell et al.”
BackgroundRelative Potency of Eltanolone, Propofol, and Thiopental for Induction of Anesthesia
Hemelrijck, J. H. V., Müller, P., Aken, H. V., & White, P. F. (1994) · Anesthesiology · doi:10.1097/00000542-199401000-00009 · Cited by 51 · cited 1×
“failure), is economic in design, and has been validated elsewhere in the anesthetic literature.(14,15) To place our data in the proper perspective, it is important to understand the strengths and limitations of the determinations of the ED50 and ED95.”
Cited by
Deer, T., Krames, E. S., Hassenbusch, S. J., Burton, A., Caraway, D., Dupen, S., Eisenach, J., Erdek, M., Grigsby, E., Kim, P., et al. (2007) · Neuromodulation: Technology at the Neural Interface · doi:10.1111/j.1525-1403.2007.00128.x · Cited by 240
Patient Preferences for Anesthesia Outcomes Associated with Cesarean Delivery
Carvalho, B., Cohen, S. E., Lipman, S. S., Fuller, A., Mathusamy, A. D., & Macario, A. (2005) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000167774.36833.99 · Cited by 197
Self-citationArzola, C., & Wieczorek, P. M. (2011) · British Journal of Anaesthesia · doi:10.1093/bja/aer200 · Cited by 180
Minimum effective bolus dose of oxytocin during elective Caesarean delivery
Butwick, A. J., Coleman, L., Cohen, S. E., Riley, E. T., & Carvalho, B. (2010) · British Journal of Anaesthesia · doi:10.1093/bja/aeq004 · Cited by 152
Self-citation
Metadata
- Authors
- Ginosar, Y., Mirikatani, E., Drover, D. R., Cohen, S. E., & Riley, E. T.
- Venue
- Anesthesiology
- Published
- 2004-03-01
- Volume
- 100
- Issue
- 3
- Pages
- 676-682
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W2063723858
- Cited by
- 181
- References
- 4
- FWCI
- 7.57
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: ED50and ED95of Intrathecal Hyperbaric Bupivacaine Coadministered with Opioids for Cesarean Delivery. https://app.cochat.ai/papers/10.1097/00000542-200403000-00031
- The paper
- Ginosar, Y., Mirikatani, E., Drover, D. R., Cohen, S. E., & Riley, E. T. (2004). ED50and ED95of Intrathecal Hyperbaric Bupivacaine Coadministered with Opioids for Cesarean Delivery. Anesthesiology. https://doi.org/10.1097/00000542-200403000-00031
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.