Can Acceleromyography Detect Low Levels of Residual Paralysis?: A Probability Approach to Detect a Mechanomyographic Train-of-four Ratio of 0.9
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
Background: The incidence of residual paralysis, i.e., a mechanomyographic train-of-four (TOF) ratio (T4/T1) less than 0.9, remains frequent. Routine acceleromyography has been proposed to detect residual paralysis in clinical practice. Although acceleromyographic data are easy to obtain, they differ from mechanomyographic data, with which they are not interchangeable. The current study aimed to determine (1) the acceleromyographic TOF ratio that detects residual paralysis with a 95% probability, and (2) the impact of calibration and normalization on this predictive acceleromyographic value. Methods: In 60 patients, recovery from neuromuscular block was assessed simultaneously with mechanomyography and acceleromyography. To obtain calibrated acceleromyographic TOF ratios in group A, the implemented calibration modus 2 was activated in the TOF-Watch S; to obtain uncalibrated acceleromyographic TOF ratios in group B, the current was manually set at 50 mA (n = 30 for each). In addition, data in group B were normalized (i.e., dividing the final TOF ratio by the baseline value). The agreement between mechanomyography and acceleromyography was assessed by calculating the intraclass correlation coefficient. Negative predictive values were calculated for detecting residual paralysis from acceleromyographic TOFs of 0.9, 0.95, and 1.0. Results: Group A: : For a mechanomyographic TOF of 0.9 or greater, the corresponding acceleromyographic TOF was 0.95 (range, 0.86-1.0), and the negative predictive values for acceleromyographic TOFs of 0.9, 0.95, and 1.0 were 37% (95% CI, 20-56%), 70% (95% CI, 51-85%), and 97% (95% CI, 83-100%), respectively. Group B: Without normalization, an acceleromyographic TOF of 0.97 (range, 0.68-1.18) corresponded to a mechanomyographic TOF of 0.9 or greater, with negative predictive values for acceleromyographic TOFs of 0.9, 0.95, and 1.0 being 40% (95% CI, 23-59%), 60% (95% CI, 41-77%), and 77% (95% CI, 58-90%), respectively. After normalization, an acceleromyographic TOF of 0.89 (range, 0.63-1.06) corresponded to a mechanomyographic TOF of 0.9 or greater, and the negative predictive values of acceleromyographic TOFs of 0.9, 0.95, and 1.0 were 89% (95% CI, 70-98%), 92% (95% CI, 75-99%), and 96% (95% CI, 80-100%), respectively. Conclusion: To exclude residual paralysis reliably when using acceleromyography, TOF recovery to 1.0 is mandatory.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intraclass correlations: Uses in assessing rater reliability.
Shrout, P. E., & Fleiss, J. L. (1979) · Psychological Bulletin · doi:10.1037/0033-2909.86.2.420 · Cited by 24,532
BERG, H., VIBY‐MOGENSEN, J., ROED, J., MORTENSEN, C. R., ENGBÆK, J., SKOVGAARD, L. T., & KRINTEL, J. J. (1997) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.1997.tb04851.x · Cited by 647 · cited 1×
“7 or less is a risk factor for development of postoperative pulmonary complications.(2) Recently, Kopman et al.”
BackgroundGood Clinical Research Practice (GCRP) in pharmacodynamic studies of neuromuscular blocking agents
Viby-Mogensen, J., Engbæk, J., Eriksson, L. I., Gramstad, L., Jensen, E. K., Jensen, F. S., Koscielniak-Nielsen, Z. J., Skovgaard, L. T., & Østergaard, D. (1996) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.1996.tb04389.x · Cited by 564
Eriksson, L. I., Sundman, E., Olsson, R., Nilsson, L., Witt, H., Ekberg, O., & Kuylenstierna, R. (1997) · Anesthesiology · doi:10.1097/00000542-199711000-00005 · Cited by 424 · cited 1×
“9, there is a significant decrease in carotid body chemosensitivity to hypoxia,(4,5) as well as pharyngeal dysfunction with an increased risk for aspiration.(6,7) Therefore, return to normal muscle function, including normal pharyngeal function, requires a mechanomyographic adductor pollicis TOF ratio of 0.”
BackgroundKopman, A. F., Yee, P. S., & Neuman, G. G. (1997) · Anesthesiology · doi:10.1097/00000542-199704000-00005 · Cited by 380
Evidence-based Practice and Neuromuscular Monitoring: It's Time for Routine Quantitative Assessment
Eriksson, L. I. (2003) · Anesthesiology · doi:10.1097/00000542-200305000-00002 · Cited by 200 · cited 1×
“This highlights the need for quantitative TOF measurement each time a muscle relaxant is given.(12) However, no mechanomyographic or electromyographic monitors that meet the single criteria of usability in the clinical setting are commercially available.”
BackgroundResidual curarization in the recovery room after vecuronium
Baillard, C., Gehan, G., Reboul-Marty, J., Larmignat, P., Samama, C. M., & Cupa, M. (2000) · British Journal of Anaesthesia · doi:10.1093/oxfordjournals.bja.a013445 · Cited by 199
The TOF‐Guard neuromuscular transmission monitor
Loan, P. B., Paxton, L. D., Mirakhur, R. K., Connolly, F. M., & McCoy, E. P. (1995) · Anaesthesia · doi:10.1111/j.1365-2044.1995.tb06097.x · Cited by 63
Albaiceta, G. M., Piacentini, E. A., Villagra, A. L. R., López‐Aguilar, J., Taboada, F., & Blanch, L. L. (2003) · Critical Care Medicine · doi:10.1097/01.ccm.0000090003.87219.aa · Cited by 37 · cited 1×
“relation coefficients were calculated.(20,21) In addition, the negative predictive values of acceleromyographic TOFs of 0.”
MethodKirkegaard-Nielsen, H., Helbo-Hansen, H. S., Lindholm, P., Pedersen, H. S., Severinsen, I. K., & Schmidt, M. B. (1998) · Journal of Clinical Monitoring and Computing · doi:10.1023/b:jocm.0000012481.06502.02 · Cited by 37
Cited by
Fuchs‐Buder, T., Claudius, C., Skovgaard, L. T., Eriksson, L. I., Mirakhur, R. K., & Viby‐Mogensen, J. (2007) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.2007.01352.x · Cited by 606
Self-citationThilen, S. R., Weigel, W. A., Todd, M. M., Dutton, R. P., Lien, C. A., Grant, S. A., Szokol, J. W., Eriksson, L. I., Yaster, M., Grant, M. D., et al. (2023) · Anesthesiology · doi:10.1097/aln.0000000000004379 · Cited by 392
Kirmeier, E., Eriksson, L. I., Lewald, H., Jonsson Fagerlund, M., Hoeft, A., Hollmann, M., Meistelman, C., Hunter, J. M., Ulm, K., Blobner, M., et al. (2019) · The Lancet Respiratory Medicine · doi:10.1016/s2213-2600(18)30294-7 · Cited by 372
Murphy, G. S., Szokol, J. W., Marymont, J. H., Greenberg, S. B., Avram, M. J., Vender, J. S., & Nisman, M. (2008) · Anesthesiology · doi:10.1097/aln.0b013e318182af3b · Cited by 315
Brull, S. J., & Murphy, G. S. (2010) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e3181da8312 · Cited by 288
Fuchs-Buder, T., Romero, C. S., Lewald, H., Lamperti, M., Afshari, A., Hristovska, A.-M., Schmartz, D., Hinkelbein, J., Longrois, D., Popp, M., et al. (2023) · European Journal of Anaesthesiology · doi:10.1097/eja.0000000000001769 · Cited by 247
Self-citationBlobner, M., Eriksson, L. I., Scholz, J., Motsch, J., Della Rocca, G., & Prins, M. E. (2010) · European Journal of Anaesthesiology · doi:10.1097/eja.0b013e32833d56b7 · Cited by 233
Reversal with Sugammadex in the Absence of Monitoring Did Not Preclude Residual Neuromuscular Block
Kotake, Y., Ochiai, R., Suzuki, T., Ogawa, S., Takagi, S., Ozaki, M., Nakatsuka, I., & Takeda, J. (2013) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e3182999672 · Cited by 204
Metadata
- Authors
- Capron, F., Alla, F., Hottier, C., Meistelman, C., & Fuchs-Buder, T.
- Venue
- Anesthesiology
- Published
- 2004-05-01
- Volume
- 100
- Issue
- 5
- Pages
- 1119-1124
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W2154969144
- Cited by
- 198
- References
- 10
- FWCI
- 7.64
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.