Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 315

The DOI matches its Crossref record.

Intraoperative Acceleromyographic Monitoring Reduces the Risk of Residual Neuromuscular Blockade and Adverse Respiratory Events in the Postanesthesia Care Unit

Murphy, Glenn S., Szokol, Joseph W., Marymont, Jesse H., Greenberg, Steven B., Avram, Michael J., Vender, Jeffery S., Nisman, Margarita·2008·Anesthesiology

Abstract

Background: Incomplete recovery from neuromuscular blockade in the postanesthesia care unit (PACU) may contribute to adverse postoperative respiratory events. This study determined the incidence and degree of residual neuromuscular blockade in patients randomized to conventional qualitative train-of-four (TOF) monitoring or quantitative acceleromyographic monitoring. The incidence of adverse respiratory events in the PACU was also evaluated. Methods: One hundred eighty-five patients were randomized to intraoperative acceleromyographic monitoring (acceleromyography group) or qualitative TOF monitoring (TOF group). Anesthetic management was standardized. TOF patients were extubated when standard criteria were met and no fade was observed during TOF stimulation. Acceleromyography patients had a TOF ratio of greater than 0.80 as an additional extubation criterion. Upon arrival in the PACU, TOF ratios of both groups were measured with acceleromyography. Adverse respiratory events during transport to the PACU and during the first 30 min of PACU admission were also recorded. Results: A lower frequency of residual neuromuscular blockade in the PACU (TOF ratio < or = 0.9) was observed in the acceleromyography group (4.5%) compared with the conventional TOF group (30.0%; P < 0.0001). During transport to the PACU, fewer acceleromyography patients developed arterial oxygen saturation values, measured by pulse oximetry, of less than 90% (0%) or airway obstruction (0%) compared with TOF patients (21.1% and 11.1%, respectively; P < 0.002). The incidence, severity, and duration of hypoxemic events during the first 30 min of PACU admission were less in the acceleromyography group (all P < 0.0001). Conclusions: Incomplete neuromuscular recovery can be minimized with acceleromyographic monitoring. The risk of adverse respiratory events during early recovery from anesthesia can be reduced by intraoperative acceleromyography use.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/aln.0b013e318182af3b

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 315

Metadata

Authors
Murphy, G. S., Szokol, J. W., Marymont, J. H., Greenberg, S. B., Avram, M. J., Vender, J. S., & Nisman, M.
Venue
Anesthesiology
Published
2008-09-01
Volume
109
Issue
3
Pages
389-398
ISSN
0003-3022 (ISSN-L)
OpenAlex
W2060418932
Cited by
315
References
0
FWCI
26.35
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Intraoperative Acceleromyographic Monitoring Reduces the Risk of Residual Neuromuscular Blockade and Adverse Respiratory Events in the Postanesthesia Care Unit. https://app.cochat.ai/papers/10.1097/aln.0b013e318182af3b
The paper
Murphy, G. S., Szokol, J. W., Marymont, J. H., Greenberg, S. B., Avram, M. J., Vender, J. S., & Nisman, M. (2008). Intraoperative Acceleromyographic Monitoring Reduces the Risk of Residual Neuromuscular Blockade and Adverse Respiratory Events in the Postanesthesia Care Unit. Anesthesiology. https://doi.org/10.1097/aln.0b013e318182af3b

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.