Injuries and Liability Related to Central Vascular Catheters: A Closed Claims Analysis
Open accessThe DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
Background: To assess changing patterns of injury and liability associated with central venous or pulmonary artery catheters, the authors analyzed closed malpractice claims for central catheter injuries in the American Society of Anesthesiologists Closed Claims database. Methods: All claims for which a central catheter (i.e., central venous or pulmonary artery catheter) was the primary damaging event for the injury were compared with the rest of the claims in the database. Central catheter complications were defined as being related to vascular access or catheter use or maintenance. Statistical analysis was performed using the chi-square test, Fisher exact test, or Z test (proportions) and the Kolmogorov-Smirnov test (payments). Results: The database included 110 claims for injuries related to central catheters (1.7% of 6,449 claims). Claims for central catheter injuries had a higher severity of injury, with an increased proportion of death (47%) compared with other claims in the database (29%, P < 0.01). The most common complications were wire/catheter embolus (n = 20), cardiac tamponade (n = 16), carotid artery puncture/cannulation (n =16), hemothorax (n =15), and pneumothorax (n =14). Cardiac tamponade, hemothorax, and pulmonary artery rupture had a higher proportion of death (P < 0.05) compared with the rest of the central catheter injures. The proportion of claims for vascular access injury increased (47% to 84%) and use/maintenance injury decreased (53% to 16%) in 1994-1999 compared with 1978-1983 (P < 0.05). Conclusions: Claims related to central catheters had a high severity of patient injury. The most common complications causing injury were wire/catheter embolus, cardiac tamponade, carotid artery puncture/cannulation, hemothorax, and pneumothorax.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Preventing Complications of Central Venous Catheterization
McGee, D. C., & Gould, M. K. (2003) · New England Journal of Medicine · doi:10.1056/nejmra011883 · Cited by 2,290 · cited 2×
“1% after subclavian vein catheterization.(2,3,14,21) Pneumothorax is a rare complication of internal jugular vein cannulation but does occur, especially with a low anterior or a posterior approach.”
BackgroundSandham, J. D., Hull, R. D., Brant, R. F., Knox, L., Pineo, G. F., Doig, C. J., Laporta, D. P., Viner, S., Passerini, L., Devitt, H., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa021108 · Cited by 1,529
Merrer, J. (2001) · JAMA · doi:10.1001/jama.286.6.700 · Cited by 1,187
Ultrasound guidance for placement of central venous catheters: A meta-analysis of the literature
Randolph, A. G., Cook, D. J., Gonzales, C. A., & Pribble, C. G. (1996) · Critical Care Medicine · doi:10.1097/00003246-199612000-00020 · Cited by 852 · cited 1×
“to inconsistent efficacy of ultrasound in clinical trials in catheterization of the subclavian vein.(2,7,11,12) Injuries”
BackgroundComplications and Failures of Subclavian-Vein Catheterization
(1995) · New England Journal of Medicine · doi:10.1056/nejm199506083322313 · Cited by 626 · cited 2×
“1% after subclavian vein catheterization.(2,3,14,21) Pneumothorax is a rare complication of internal jugular vein cannulation but does occur, especially with a low anterior or a posterior approach.”
BackgroundDenys, B. G., Uretsky, B. F., & Reddy, P. S. (1993) · Circulation · doi:10.1161/01.cir.87.5.1557 · Cited by 543
Central Vein Catheterization: Failure and Complication Rates by Three Percutaneous Approaches
Sznajder, J. I. (1986) · Archives of Internal Medicine · doi:10.1001/archinte.1986.00360140065007 · Cited by 496
Cheney, F. W. (1999) · Anesthesiology · doi:10.1097/00000542-199908000-00030 · Cited by 329 · cited 2×
“Methodologic Issues When interpreting the results, it should be emphasized that closed claims analysis has a number of well-described limitations.(8,9) Because of the lack of denominator data, the Closed Claims database only provides an indirect assessment of the hazards of central catheters and liability risks faced…”
BackgroundMethodSelf-citationUltrasound-Guided Cannulation of the Internal Jugular Vein. A Prospective, Randomized Study
Troianos, C. A., Jobes, D. R., & Ellison, N. (1991) · Anesthesia & Analgesia · doi:10.1213/00000539-199106000-00020 · Cited by 314
A Review of Pulmonary Artery Catheterization in 6,245 Patients
Shah, K. B., Rao, T. L. K., Laughlin, S., & El-Etr, A. A. (1984) · Anesthesiology · doi:10.1097/00000542-198409000-00007 · Cited by 300
Dee Boyd, K., Thomas, S. J., Gold, J., & Boyd, A. D. (1983) · Chest · doi:10.1378/chest.84.3.245 · Cited by 291
Measuring interrater reliability among multiple raters: An example of methods for nominal data
Posner, K. L., Sampson, P. D., Caplan, R. A., Ward, R. J., & Cheney, F. W. (1990) · Statistics in Medicine · doi:10.1002/sim.4780090917 · Cited by 229 · cited 1×
“The reliability of reviewer judgments previously has been found to be acceptable.(10)”
BackgroundSelf-citationStandard of Care and Anesthesia Liability
Cheney, F. W. (1989) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1989.03420110075027 · Cited by 193
Self-citationSafer Jugular Vein Cannulation
Jobes, D. R., Schwartz, A. J., Greenhow, D. E., Stephenson, L. W., & D, N. E. M. (1983) · Anesthesiology · doi:10.1097/00000542-198310000-00017 · Cited by 152
Complications Associated with Central Venous Catheters
Scott, W. L. (1988) · CHEST Journal · doi:10.1378/chest.94.6.1221 · Cited by 143 · cited 1×
“Pneumothorax is a rare complication of internal jugular vein cannulation but does occur, especially with a low anterior or a posterior approach.(15,21) The relatively low number of claims for pneumothorax, despite the relatively high frequency of occurrence after subclavian vein catheterization, is probably related to…”
BackgroundCharacteristics of Potential Plaintiffs in Malpractice Litigation
Huycke, L. I., & Huycke, M. M. (1994) · Annals of Internal Medicine · doi:10.7326/0003-4819-120-9-199405010-00011 · Cited by 102 · cited 1×
“Closed Claims are biased by the presence of more severe and costly injuries because plaintiff attorneys are unlikely to pursue claims with an estimated financial recovery for damage of less than $50,000.(13) The analysis only evaluated information in the database that was transcribed to the data sheet by the reviewer,…”
BackgroundLefrant, J. Y., Cuvillon, P., Bénézet, J., Dauzat, M., Fabbro-Péray, P., Saïssi, G., Coussaye, J.-E. D. L., & Eledjam, J. (1998) · Anesthesiology · doi:10.1097/00000542-199805000-00009 · Cited by 102 · cited 2×
“to inconsistent efficacy of ultrasound in clinical trials in catheterization of the subclavian vein.(2,7,11,12) Injuries”
Background[Ultrasound guidance for placement of central venous catheters].
Åsheim, P., Aadahl, P., & Fasting, S. (1999) · PubMed · Cited by 94
Incidence and management of large-bore introducer sheath puncture of the carotid artery
Golden, L. R. (1995) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1016/s1053-0770(05)80098-9 · Cited by 72 · cited 2×
“Pressure waveform monitoring positively identifies venous versus arterial access,(22) although misleading results can be obtained if the fluid pathway between the vessel and pressure transducer is compromised.(26) Our results suggest that use of pressure waveform monitoring during placement to prevent accidental arter…”
BackgroundBar‐Joseph, G., & Galvis, A. G. (1983) · Journal of Pediatric Surgery · doi:10.1016/s0022-3468(83)80103-1 · Cited by 68 · cited 1×
“The increased proportion of patients aged between 2 months and 6 yr in our claims for cardiac tamponade supports an increased risk of cardiac tamponade with central catheters in pediatric patients.(17) Predisposing factors for cardiac tamponade include catheter tip location within the heart and an angle of the cathete…”
BackgroundSheep, R. E. (1982) · JAMA · doi:10.1001/jama.248.13.1632 · Cited by 60
Case 1—1996 inadvertent carotid artery cannulation during pulmonary artery catheter insertion
Eckhardt, W. F., Iaconetti, D. J., Kwon, J. S., Brown, E. N., & Troianos, C. A. (1996) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1016/s1053-0770(96)80252-7 · Cited by 42
Intraoperative Cardiac Tamponade After Central Venous Cannulation
Jiha, J. G., Weinberg, G. L., & Laurito, C. E. (1996) · Anesthesia & Analgesia · doi:10.1097/00000539-199603000-00041 · Cited by 27
Cited by
Bhananker, S. M., Ramamoorthy, C., Geiduschek, J. M., Posner, K. L., Domino, K. B., Haberkern, C. M., Campos, J. S., & Morray, J. P. (2007) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000268712.00756.dd · Cited by 720
Self-citationUltrasound guidance versus anatomical landmarks for internal jugular vein catheterization
Brass, P., Hellmich, M., Kolodziej, L., Schick, G., & Smith, A. F. (2015) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd006962.pub2 · Cited by 476
Metzner, J., Posner, K. L., Lam, M. S., & Domino, K. B. (2011) · Best Practice & Research Clinical Anaesthesiology · doi:10.1016/j.bpa.2011.02.007 · Cited by 325
Self-citationAssociation of Anaesthetists of Great Britain and Ireland: Safe vascular access 2016
Bodenham (Chair), A., Babu, S., Bennett, J., Binks, R., Fee, P., Fox, B., Johnston, A. J., Klein, A. A., Langton, J. A., Mclure, H., et al. (2016) · Anaesthesia · doi:10.1111/anae.13360 · Cited by 309
Clinical guidelines on central venous catheterisation
FRYKHOLM, P., PIKWER, A., HAMMARSKJÖLD, F., LARSSON, A. T., LINDGREN, S., LINDWALL, R., TAXBRO, K., ÖBERG, F., ACOSTA, S., & ÅKESON, J. (2014) · Acta Anaesthesiologica Scandinavica · doi:10.1111/aas.12295 · Cited by 218
“In case reports, fatal outcome due to bleeding is most often considered a consequence of inadequate technique or management rather than bleeding diathesis.(6,7) Bleeding complications associated with CVC removal are rare(8,9) and have not been reported to be associated with moderately decreased platelet count”
Background
Metadata
- Authors
- Domino, K. B., Bowdle, T. A., Posner, K. L., Spitellie, P. H., Lee, L. A., & Cheney, F. W.
- Venue
- Anesthesiology
- Published
- 2004-06-01
- Volume
- 100
- Issue
- 6
- Pages
- 1411-1418
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W1985152184
- Cited by
- 244
- References
- 23
- FWCI
- 38.35
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.