Estimation of Mean Body Temperature from Mean Skin and Core Temperature
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Background: Mean body temperature (MBT) is the mass-weighted average temperature of body tissues. Core temperature is easy to measure, but direct measurement of peripheral tissue temperature is painful and risky and requires complex calculations. Alternatively MBT can be estimated from core and mean skin temperatures with a formula proposed by Burton in 1935: MBT = 0.64 x TCore + 0.36 x TSkin. This formula remains widely used, but has not been validated in the perioperative period and seems unlikely to remain accurate in dynamic perioperative conditions such as cardiopulmonary bypass. Therefore, the authors tested the hypothesis that MBT, as estimated with Burton's formula, poorly estimates measured MBT at a temperature range between 18 degrees and 36.5 degrees C. Methods: The authors reevaluated four of their previously published studies in which core and mass-weighted mean peripheral tissue temperatures were measured in patients undergoing substantial thermal perturbations. Peripheral compartment temperatures were estimated using fourth-order regression and integration over volume from 18 intramuscular needle thermocouples, 9 skin temperatures, and "deep" hand and foot temperature. MBT was determined from mass-weighted average of core and peripheral tissue temperatures and estimated from core temperature and mean skin temperature (15 area-weighted sites) using Burton's formula. Results: Nine hundred thirteen data pairs from 44 study subjects were included in the analysis. Measured MBT ranged from 18 degrees to 36.5 degrees C. There was a remarkably good relation between measured and estimated MBT: MBTmeasured = 0.94 x MBTestimated + 2.15, r = 0.98. Differences between the estimated and measured values averaged -0.09 degrees +/- 0.42 degrees C. Conclusions: The authors concluded that estimation of MBT from mean skin and core temperatures is generally accurate and precise.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Cited by
Monitoring of Vital Signs with Flexible and Wearable Medical Devices
Khan, Y., Ostfeld, A. E., Lochner, C. M., Pierre, A., & Arias, A. C. (2016) · Advanced Materials · doi:10.1002/adma.201504366 · Cited by 1,408
Temperature Monitoring and Perioperative Thermoregulation
Sessler, D. I., Warner, D. S., & Warner, M. A. (2008) · Anesthesiology · doi:10.1097/aln.0b013e31817f6d76 · Cited by 758
“Both core and mean skin-surface temperature measurements are required to determine the thermoregulatory effects of different anesthetic drugs(11) and estimate mean body temperature (MBT).(12)”
BackgroundSelf-citationPerioperative thermoregulation and heat balance
Sessler, D. I. (2016) · The Lancet · doi:10.1016/s0140-6736(15)00981-2 · Cited by 593
Self-citationA Zigbee-Based Wearable Physiological Parameters Monitoring System
Malhi, K., Mukhopadhyay, S. C., Schnepper, J., Haefke, M., & Ewald, H. (2012) · IEEE Sensors Journal · doi:10.1109/jsen.2010.2091719 · Cited by 282
Subjective and Psychophysiological Indexes of Listening Effort in a Competing-Talker Task
Mackersie, C. L., & Cones, H. (2011) · Journal of the American Academy of Audiology · doi:10.3766/jaaa.22.2.6 · Cited by 172
“The temperature sensor is capable of detecting changes of up to 1/1000th of a degree Fahrenheit over a range of 50–104 F. Typically skin temperature is lower than the body’s actual internal temperature, by 5–6 F (Lenhardt and Sessler, 2006).”
Metadata
- Authors
- Lenhardt, R., & Sessler, D. I.
- Venue
- Anesthesiology
- Published
- 2006-12-01
- Volume
- 105
- Issue
- 6
- Pages
- 1117-1121
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W2143425676
- Cited by
- 101
- References
- 1
- FWCI
- 0.86
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Estimation of Mean Body Temperature from Mean Skin and Core Temperature. https://app.cochat.ai/papers/10.1097/00000542-200612000-00011
- The paper
- Lenhardt, R., & Sessler, D. I. (2006). Estimation of Mean Body Temperature from Mean Skin and Core Temperature. Anesthesiology. https://doi.org/10.1097/00000542-200612000-00011
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.