A Small Arterial substitute: Expanded Microporous Polytetrafluoroethylene. Patency Versus Porosity
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Eighty-nine grafts of expanded microporous polytetrafluoroethylene (PTFE) with a diameter of 4 mm, were placed in the carotid and femoral arteries of dogs. The animals were sacrificed at varying intervals beginning three days after operation. Four animals remain alive with patent grafts 10 months post-operatively. Twenty-four of 89 grafts were occluded, an overall patency of 73%. Fibril length (pore size) of the graft material was varied from 4 to 110 microns. Average pore size ranged from 9 to 65 microns. Wall thickness varied from 0.3 to 0.75 mm. Density ranged from 0.24 to 0.35 g/ml. Tissue ingrowth, neointimization and patency rate as compared to pore size, wall-thickness and density of expanded PTFE were observed. Pore size is the primary determinant of tissue ingrowth, neointimization and patency. Of 51 grafts with an average pore size of 22 microns or less, there were 6 occlusions, an 88% patency rate. There were 38 grafts with an average pore size of 34 microns or greater. In these 38 grafts, 18 occlusions were observed, a 53% patency rate. Patent grafts demonstrated tissue ingrowth, capillary formation an a thin neointima. Using small pore grafts, patency rates of 90% can be anticipated in the dog. Expanded microporous PTFE with its ease of handling, strength and pliability may be the vascular prosthesis of choice in man.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Healing of Arterial Prostheses in Man
Berger, K., Sauvage, L. R., Rao, A. M., & Wood, S. J. (1972) · Annals of Surgery · doi:10.1097/00000658-197201000-00018 · Cited by 442
Porosity: primary determinant of ultimate fate of synthetic vascular grafts.
WESOLOWSKI, S. A., Cc, F., Karlson, K. E., BAKEY, M. E. D., & Pn, S. (1961) · PubMed · Cited by 241
A new vascular prosthesis for a small caliber artery.
Matsumoto, H., Hasegawa, T., Fuse, K., Yamamoto, M., & Saigusa, M. (1973) · PubMed · Cited by 213
The compound prosthetic vascular graft: a pathologic survey.
Wesolowski, S. A., FRIES, C. C., Rt, D., Liebig, W. J., & Sawyer, P. N. (1963) · PubMed · Cited by 91
Nonthrombogenic materials via a simple coating process.
Grode, G. A., Anderson, S. J., Grotta, H. M., & Falb, R. D. (1969) · PubMed · Cited by 85
Sparks, C. H. (1970) · Annals of Surgery · doi:10.1097/00000658-197011000-00003 · Cited by 41
Cited by
Prosthetic vascular grafts: Wrong models, wrong questions and no healing
Zilla, P., Bezuidenhout, D., & Human, P. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.07.017 · Cited by 542
Effect of compliance mismatch on vascular graft patency
Abbott, W. M., Megerman, J., Hasson, J. E., L'Italien, G., & Warnock, D. F. (1987) · Journal of Vascular Surgery · doi:10.1016/0741-5214(87)90148-0 · Cited by 484
Tissue Engineering of Small Diameter Vascular Grafts
Teebken, O. E., & Haverich, A. (2002) · European Journal of Vascular and Endovascular Surgery · doi:10.1053/ejvs.2002.1654 · Cited by 268
Hernandez, J. L., & Woodrow, K. A. (2022) · Advanced Healthcare Materials · doi:10.1002/adhm.202102087 · Cited by 259
Healing of polytetrafluoroethylene arterial grafts is influenced by graft porosity
Golden, M. A., Hanson, S. R., Kirkman, T. R., Schneider, P. A., & Clowes, A. W. (1990) · Journal of Vascular Surgery · doi:10.1016/0741-5214(90)90082-l · Cited by 206
A study of the interface between a fibrous polyurethane arterial prosthesis and natural tissue
Beahan, P., & Hull, D. (1982) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820160608 · Cited by 17
Metadata
- Authors
- CAMPBELL, C. D., GOLDFARB, D., & ROE, R.
- Venue
- Annals of Surgery
- Published
- 1975-08
- Volume
- 182
- Issue
- 2
- Pages
- 138-143
- ISSN
- 0003-4932 (ISSN-L)
- OpenAlex
- W2085894974
- Cited by
- 221
- References
- 6
- FWCI
- 15.88
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.