The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Elevated Intra-abdominal Pressure and Renal Function
Open accessAbstract
The effect of increased intra-abdominal pressure on cardiac output and renal function was investigated using anesthetized dogs into whom inflatable intraperitoneal bags were placed. Hemodynamic and renal function measurements were made at intra-abdominal pressures of 0, 20, and 40 mmHg. Renal blood flo and glomerular filtration rate decreased to les than 25% of normal when the intra-abdominal pressure was elevated to 20 mmHg. At 40 mmHg intra-abdominal pressure, three dogs became anuric, and the renal blood flow and glomerular filtration rate of the remaining dogs was 7% of normal, while cardiac output was reduced to 37% of normal. Expansion of the blood volume using Dextran-40 easily corrected the deficit in cardiac output, but renal blood flow and glomerular filtration rate remained less than 25% of normal. Renal vascular resistance increased 555% when the intra-abdominal pressure was elevated from 0 to 20 mmHg, an increase fifteen-fold that of systemic vascular resistance. This suggests that the impairment in renal function produced by increased intra-abdominal pressure is a local phenomenon caused by direct renal compression and is not related to cardiac output.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hemodynamic effects of increased abdominal pressure
Kashtan, J., Green, J. F., Parsons, E. Q., & Holcroft, J. W. (1981) · Journal of Surgical Research · doi:10.1016/0022-4804(81)90156-6 · Cited by 455
Hemodynamic and respiratory alterations with increased intra-abdominal pressure
Richardson, J. D., & Trinkle, J. K. (1976) · Journal of Surgical Research · doi:10.1016/0022-4804(76)90112-8 · Cited by 326
Mechanism of acute hemodynamic response to ureteral occlusion.
Vaughan, E. D., Shenasky, J. H., & Gillenwater, J. Y. (1971) · PubMed · Cited by 100
Cited by
Splanchnic Ischemia and Bacterial Translocation in the Abdominal Compartment Syndrome
Diebel, L. N., Dulchavsky, S. A., & Brown, W. J. (1997) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/00005373-199711000-00019 · Cited by 288
What is Normal Intra-Abdominal Pressure?
Sanchez, N. C., Tenofsky, P. L., Dort, J. M., Shen, L. Y., Helmer, S. D., & Smith, R. S. (2001) · The American Surgeon · doi:10.1177/000313480106700308 · Cited by 279
Effect of Increased Renal Venous Pressure on Renal Function
Doty, J. M., Saggi, B. H., Sugerman, H. J., Blocher, C. R., Pin, R., Fakhry, I., Gehr, T. W. B., & Sica, D. A. (1999) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/00005373-199912000-00002 · Cited by 269
Acute mesenteric ischemia: Pathophysiology, diagnosis, and treatment
Benjamin, E., & Oropello, J. M. (1993) · Disease-a-Month · doi:10.1016/0011-5029(93)90023-v · Cited by 150
Regueira, T., Bruhn, A., Hasbun, P., Aguirre, M., Romero, C., Llanos, O., Castro, R., Bugedo, G., & Hernandez, G. (2008) · Journal of Critical Care · doi:10.1016/j.jcrc.2007.12.013 · Cited by 84
Metadata
- Authors
- HARMAN, P. K., KRON, I. L., McLACHLAN, H. D., FREEDLENDER, A. E., & NOLAN, S. P.
- Venue
- Annals of Surgery
- Published
- 1982-11
- Volume
- 196
- Issue
- 5
- Pages
- 594-597
- ISSN
- 0003-4932 (ISSN-L)
- OpenAlex
- W2014386792
- Cited by
- 554
- References
- 3
- FWCI
- 4.86
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Elevated Intra-abdominal Pressure and Renal Function. https://app.cochat.ai/papers/10.1097/00000658-198211000-00015
- The paper
- HARMAN, P. K., KRON, I. L., McLACHLAN, H. D., FREEDLENDER, A. E., & NOLAN, S. P. (1982). Elevated Intra-abdominal Pressure and Renal Function. Annals of Surgery. https://doi.org/10.1097/00000658-198211000-00015
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.