Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 279

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

What is Normal Intra-Abdominal Pressure?

Sanchez, Noel C., Tenofsky, Patty L., Dort, Jonathan M., Shen, Luke Y., Helmer, Stephen D., Smith, R. Stephen·2001·The American Surgeon

Abstract

The causes and effects of increased intra-abdominal pressure and abdominal compartment syndrome have been well documented. However, there have been no large series to determine normal intra-abdominal pressure in hospitalized patients. The purpose of this study was to determine normal intra-abdominal pressure in randomly selected hospitalized patients and to identify factors that predict variation in normal intra-abdominal pressure. A total of 77 patients were prospectively enrolled between September 1998 and July 1999. Data obtained included patient demographics (i.e., age, gender, height, weight, and body mass index), reason for hospitalization and bladder catheterization, previous and current surgical status, comorbidities, and intra-abdominal pressures. Intra-abdominal pressure readings were obtained through an indwelling transurethral bladder (Foley) catheter. Data were analyzed by analysis of variance and multiple regression analysis. There were 36 females and 41 males with a mean age of 67.7 years. Average weight, height, and body mass index were 79.6 kg, 1.70 m, and 27.6 kg/m 2, respectively. Mean intraabdominal pressure was 6.5 mm Hg (range 0.2–16.2 mm Hg). Body mass index was positively related to intra-abdominal pressure ( P < 0.0004). Gender, age, and medical and surgical histories did not significantly affect intra-abdominal pressure. However, using multiple regression analysis, a relationship between intra-abdominal pressure, body mass index, and abdominal surgery was discovered. Intra-abdominal pressure is related to a patient's body mass index and influenced by recent abdominal surgery. Thus, the normal intra-abdominal pressure can be estimated in hospitalized patients by using the derived equation. Knowledge of the expected intra-abdominal pressure can then by used in recognizing when an abnormally high intra-abdominal pressure or abdominal compartment syndrome exists.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/000313480106700308

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 11 references

Cited by

See all 279

Metadata

Authors
Sanchez, N. C., Tenofsky, P. L., Dort, J. M., Shen, L. Y., Helmer, S. D., & Smith, R. S.
Venue
The American Surgeon
Published
2001-03
Volume
67
Issue
3
Pages
243-248
ISSN
  • 0003-1348 (ISSN-L)
  • 1555-9823
OpenAlex
W4312270829
Cited by
279
References
11
FWCI
5.79
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: What is Normal Intra-Abdominal Pressure? https://app.cochat.ai/papers/10.1177/000313480106700308
The paper
Sanchez, N. C., Tenofsky, P. L., Dort, J. M., Shen, L. Y., Helmer, S. D., & Smith, R. S. (2001). What is Normal Intra-Abdominal Pressure? The American Surgeon. https://doi.org/10.1177/000313480106700308

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.