The Fibrinolytic Effects of Intermittent Pneumatic Compression: Mechanism of Enhanced Fibrinolysis
Open accessThe DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
BACKGROUND AND OBJECTIVES: Intermittent pneumatic compression (IPC) is an effective form of deep vein thrombosis prophylaxis for general surgery patients. The antithrombotic effect of IPC is thought to be the result of increased venous velocity and stimulation of endogenous fibrinolysis. However, the mechanism of enhanced fibrinolytic activity and the relative effects on normal and postthrombotic veins have not been defined. The purposes of this study are 1) to quantify changes in fibrinolytic activity with IPC; 2) to study the mechanism of fibrinolytic enhancement with IPC; and 3) to evaluate whether postthrombotic patients have the same capacity for fibrinolytic enhancement with IPC as do normal subjects. METHODS: Twelve volunteers (6 normal and 6 postthrombotic) had 5 IPC devices applied for 120 minutes in random fashion, 1 per week x 5 weeks. The devices included single-chamber, sequential, foot, calf, and long-leg compression. Subjects had an indwelling antecubital venous cannula placed for blood drawn at baseline, 60, 120, and 180 minutes after IPC devices were applied. Global fibrinolytic activity (euglobulin fraction, fibrin plate assay), tissue plasminogen activator (tPA) antigen (Ag) and activity (Act), plasminogen activator inhibitor-1 (PAI-1) Ag and Act, alpha-2-antiplasmin-plasmin complexes, and von Willebrand factor (vWF) antigen were assayed. RESULTS: A striking elevation in fibrinolytic activity was noted at 180 minutes with all devices in normal subjects and postthrombotic patients (p = 0.01-0.0001); however, baseline and stimulated fibrinolytic activity was attenuated in postthrombotic patients (<0.03). The tPA-Act increased only in normal subjects (3.8 +/- 1.9%) (p = 0.057), despite a decrease in plasma tPA-Ag, which was observed in both normal subjects (-12.4 +/- 3.8%) (p = 0.009) and patients (-17.2 +/- 3.1%) (p = 0.001). PAI-1-Ag decreased in both normal subjects (-13.4 +/- 3.8%) (p = 0.007) and patients (-12.0 +/- 3.1%) (p = 0.013) with a marked reduction in PAI-1-Act in both normal subjects (p = 0.003) and patients (p = 0.004). There were no changes in vWF, and alpha-2-antiplasmin-plasmin complexes increased only in postthrombotic patients (p = 0.021). CONCLUSIONS: Stimulation of endogenous fibrinolytic activity occurs after IPC, both in normal subjects and postthrombotic patients; however, baseline and overall fibrinolytic response in postthrombotic patients is reduced. The mechanism of increased fibrinolytic activity is likely because of a reduction in PAI-1, with a resulting increase of tPA activity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Prevention of Venous Thromboembolism
Geerts, W. H., Heit, J. A., Clagett, G. P., Pineo, G. F., Colwell, C. W., Anderson, F. A., & Wheeler, H. B. (2001) · Chest · doi:10.1378/chest.119.1_suppl.132s · Cited by 4,373
Freiman, J. A., Chalmers, T. C., Smith, H., & Kuebler, R. R. (1978) · New England Journal of Medicine · doi:10.1056/nejm197809282991304 · Cited by 1,628
Huynh, H., & Feldt, L. S. (1970) · Journal of the American Statistical Association · doi:10.1080/01621459.1970.10481187 · Cited by 946
Huynh, H., & Feldt, L. S. (1970) · Journal of the American Statistical Association · doi:10.2307/2284340 · Cited by 945
Diurnal variation of tissue-type plasminogen activator and its rapid inhibitor (PAI-1).
Angleton, P., Chandler, W. L., & Schmer, G. (1989) · Circulation · doi:10.1161/01.cir.79.1.101 · Cited by 392
Prevention of Venous Thromboembolism
Clagett, G. P., Anderson, F. A., Heit, J., Levine, M. N., & Wheeler, H. B. (1995) · Chest · doi:10.1378/chest.108.4_supplement.312s · Cited by 364
The Vascular Endothelium: A New Horizon
Davies, M. G., & Hagen, P.-O. (1993) · Annals of Surgery · doi:10.1097/00000658-199321850-00003 · Cited by 233
Preoperative prediction of postoperative deep vein thrombosis.
Clayton, J. K., Anderson, J. A., & McNicol, G. P. (1976) · BMJ · doi:10.1136/bmj.2.6041.910 · Cited by 208
Prins, M. H., & Hirsh, J. (1991) · Archives of Internal Medicine · doi:10.1001/archinte.1991.00400090023006 · Cited by 139
Chandler, W. L., Trimble, S., Loo, S., & Mornin, D. (1990) · Blood · doi:10.1182/blood.v76.5.930.930 · Cited by 111
Cited by
Prevention of Venous Thromboembolism
Geerts, W. H., Heit, J. A., Clagett, G. P., Pineo, G. F., Colwell, C. W., Anderson, F. A., & Wheeler, H. B. (2001) · Chest · doi:10.1378/chest.119.1_suppl.132s · Cited by 4,373
Acute Pulmonary Embolism: Part I: Epidemiology, Pathophysiology, and Diagnosis
Goldhaber, S. Z., & Elliott, C. G. (2003) · Circulation · doi:10.1161/01.cir.0000097829.89204.0c · Cited by 406
Prevention of Venous Thromboembolism
Clagett, G. P., Anderson, F. A., Geerts, W., Heit, J. A., Knudson, M., Lieberman, J. R., Merli, G. J., & Wheeler, H. B. (1998) · Chest · doi:10.1378/chest.114.5_supplement.531s · Cited by 378
Goldhaber, S. Z. (2004) · The Lancet · doi:10.1016/s0140-6736(04)16004-2 · Cited by 348
Predictors of Rehospitalization for Symptomatic Venous Thromboembolism after Total Hip Arthroplasty
White, R. H., Gettner, S., Newman, J. M., Trauner, K. B., & Romano, P. S. (2000) · New England Journal of Medicine · doi:10.1056/nejm200012143432403 · Cited by 260
Evidence-Based Compression: Prevention of Stasis and Deep Vein Thrombosis
Morris, R. J., & Woodcock, J. P. (2004) · Annals of Surgery · doi:10.1097/01.sla.0000109149.77194.6c · Cited by 221
“However, since 1976 when Knight and Dawson suggested that applying leg cuffs to the arm prevented DVT in legs,([55]) there has been good research into possible systemic hematological effects, particularly changes in fibrinolysis.([86-92]) Hypercoagulability is another of Virchow's triad, and its prevention, without ha…”
BackgroundDeep vein thrombosis: a clinical review
Kesieme, & Kesieme (2011) · Journal of Blood Medicine · doi:10.2147/jbm.s19009 · Cited by 208
“There is a theoretical risk of fibrinolysis and clot dislodgement.(70) Leg wrappings and stockings with no pressure gradient are ineffective in the prevention of DVT.”
Urbankova, J., Quiroz, R., Kucher, N., & Goldhaber, S. Z. (2005) · Thrombosis and Haemostasis · doi:10.1160/th05-04-0222 · Cited by 194
“Hills11 040 11 (28) 70 001/ 20 08 / 20 0.”
BackgroundLow Rate of Venous Thromboembolism After Craniotomy for Brain Tumor Using Multimodality Prophylaxis
Goldhaber, S. Z., Dunn, K., Gerhard-Herman, M., Park, J. K., & Black, P. M. (2002) · Chest · doi:10.1378/chest.122.6.1933 · Cited by 193
Secondary chronic venous disorders
Meissner, M. H., Eklof, B., Smith, P. C., Dalsing, M. C., DePalma, R. G., Gloviczki, P., Moneta, G., Neglén, P., O’ Donnell, T., Partsch, H., et al. (2007) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2007.08.048 · Cited by 159
Metadata
- Authors
- Comerota, A. J., Chouhan, V., Harada, R. N., Sun, L., Hosking, J., Veermansunemi, R., Comerota, A. J., Schlappy, D., & Rao, A. K.
- Venue
- Annals of Surgery
- Published
- 1997-09
- Volume
- 226
- Issue
- 3
- Pages
- 306-314
- ISSN
- 0003-4932 (ISSN-L)
- OpenAlex
- W2086570025
- Cited by
- 249
- References
- 13
- FWCI
- 3.24
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.