Prospective Study of Blunt Aortic Injury: Helical CT is Diagnostic and Antihypertensive Therapy Reduces Rupture

Open access
Fabian, Timothy C., Davis, Kimberly A., Gavant, Morris L., Croce, Martin A., Melton, Sherry M., Patton, Joe H., Haan, Constance K., Weiman, Darryl S., Pate, James W. · 1998 · Annals of Surgery

Abstract

OBJECTIVE: There were two aims of this study. The first was to evaluate the application of helical computed tomography of the thorax (HCTT) for the diagnosis of blunt aortic injury (BAI). The second was to evaluate the efficacy of beta-blockers with or without nitroprusside in preventing aortic rupture. SUMMARY BACKGROUND DATA: Aortography has been the standard for diagnosing BAI for the past 4 decades. Conventional chest CT has not proven to be of significant value. Helical CT scanning is faster and has higher resolution than conventional CT. Retrospective studies have suggested the efficacy of antihypertensives in preventing aortic rupture. METHODS: A prospective study comparing HCTT to aortography in the diagnosis of BAI was performed. A protocol of beta-blockers with or without nitroprusside was also examined for efficacy in preventing rupture before aortic repair and in allowing delayed repair in patients with significant associated injuries. RESULTS: Over a period of 4 years, 494 patients were studied. BAI was diagnosed in 71 patients. Sensitivity was 100% for HCTT versus 92% for aortography. Specificity was 83% for HCTT versus 99% for aortography. Accuracy was 86% for HCTT versus 97% for aortography. Positive predictive value was 50% for HCTT versus 97% for aortography. Negative predictive value was 100% for HCTT versus 97% for aortography. No patient had spontaneous rupture in this study. CONCLUSIONS: HCTT is sensitive for diagnosing intimal injuries and pseudoaneurysms. Patients without direct HCTT evidence of BAI require no further evaluation. Aortography can be reserved for indeterminate HCTT scans. Early diagnosis with HCTT and presumptive treatment with the antihypertensive regimen eliminated in-hospital aortic rupture.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00000658-199805000-00007

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 352

Metadata

Authors
Fabian, T. C., Davis, K. A., Gavant, M. L., Croce, M. A., Melton, S. M., Patton, J. H., Haan, C. K., Weiman, D. S., & Pate, J. W.
Venue
Annals of Surgery
Published
1998-05
Volume
227
Issue
5
Pages
666-677
ISSN
0003-4932 (ISSN-L)
OpenAlex
W2053671233
Cited by
352
References
3
FWCI
13.69
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Prospective Study of Blunt Aortic Injury: Helical CT is Diagnostic and Antihypertensive Therapy Reduces Rupture. https://app.cochat.ai/papers/10.1097/00000658-199805000-00007
The paper
Fabian, T. C., Davis, K. A., Gavant, M. L., Croce, M. A., Melton, S. M., Patton, J. H., Haan, C. K., Weiman, D. S., & Pate, J. W. (1998). Prospective Study of Blunt Aortic Injury: Helical CT is Diagnostic and Antihypertensive Therapy Reduces Rupture. Annals of Surgery. https://doi.org/10.1097/00000658-199805000-00007

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.