Bioabsorbable Fixation Devices: Status for the Craniomaxillofacial Surgeon
The DOI matches its Crossref record.
Abstract
With time, more and more types of medical devices become available to assist the surgeon in managing patients. Bioabsorbable fixation devices, which have been directed toward the orthopedic surgeon over the past 10 years, are but one example. One aim of this article is to present the current status of bioabsorbable devices in medical practice to the craniomaxillofacial surgeon who may not be aware of the inroads this technology has made. A bioabsorbable fixation system has become available for use by the craniomaxillofacial surgeon, which is described. A further aim of this article is to present concisely the testing rigor required of such devices before their introduction to the U.S. market. This has the added benefit of explaining the important role of the surgeon in developing and helping reduce to standard clinical practice the use of new technologies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Synthetic biodegradable polymers as orthopedic devices
Middleton, J. C., & Tipton, A. J. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00101-0 · Cited by 2,741
“Surgical Dynamics and Biomet have chosen an 82/18 poly(L-lactide-co-glycolide) copolymer for use as suture anchors and as screws and plates for craniomaxillofacial repair respectively [13, 19 ].”
BackgroundMethodInfluentialRecent Developments in Ring Opening Polymerization of Lactones for Biomedical Applications
Albertsson, A.-C., & Varma, I. K. (2003) · Biomacromolecules · doi:10.1021/bm034247a · Cited by 1,582
Pillai, C. K. S., & Sharma, C. P. (2010) · Journal of Biomaterials Applications · doi:10.1177/0885328210384890 · Cited by 353
Bioresorbable Vascular Scaffolds Versus Metallic Stents in Patients With Coronary Artery Disease
Gao, R., Yang, Y., Han, Y., Huo, Y., Chen, J., Yu, B., Su, X., Li, L., Kuo, H.-C., Ying, S.-W., et al. (2015) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2015.09.054 · Cited by 252
Biomimetic Collagen Scaffolds for Human Bone Cell Growth and Differentiation
Yang, X. B., Bhatnagar, R. S., Li, S., & Oreffo, R. O. C. (2004) · Tissue Engineering · doi:10.1089/1076327041887871 · Cited by 200
Short-Term and Long-Term Effects of Orthopedic Biodegradable Implants
Amini, A. R., Wallace, J. S., & Nukavarapu, S. P. (2011) · Journal of Long-Term Effects of Medical Implants · doi:10.1615/jlongtermeffmedimplants.v21.i2.10 · Cited by 181
Resorbable Plate Fixation in Pediatric Craniofacial Surgery: Long-term Outcome
Imola, M. J., Hamlar, D. D., Shao, W., Chowdhury, K., & Tatum, S. (2001) · Archives of Facial Plastic Surgery · doi:10.1001/archfaci.3.2.79 · Cited by 163
“Thus far, development of resorbable plates and screws has focused on polymers that are macromolecular chains composed of repeating subunits.(18,20,21) Two poly-alphahydroxy acids, polyglycolic acid (PGA) and polylactic acid (PLA), are polymers that have been used in the manufacturing of resorbable suture for several y…”
Morrison, K. A., Lee, J. C., Souweidane, M. M., Feldstein, N. A., & Ascherman, J. A. (2018) · Annals of Plastic Surgery · doi:10.1097/sap.0000000000001365 · Cited by 35
Metadata
- Authors
- Pietrzak, W. S., Verstynen, M. L., & Sarver, D. R.
- Venue
- Journal of Craniofacial Surgery
- Published
- 1997-03
- Volume
- 8
- Issue
- 2
- Pages
- 92-96
- ISSN
- 1049-2275 (ISSN-L)
- OpenAlex
- W1993404901
- Cited by
- 75
- References
- 0
- FWCI
- 2.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.