Changes in alertness are a principal component of variance in the EEG spectrum
The DOI matches its Crossref record.
Abstract
Minute-scale fluctuations in the normalized EEG log spectrum, when correlated with concurrent changes in level of performance on a sustained auditory detection task, showed that a single principal component of EEG spectral variance is linearly related to minute-scale changes in detection performance. The particular EEG frequencies at which this coupling is expressed are similar for most subjects under a range of task conditions, and match those recently reported from analysis of verbal self-reports during drowsiness. The one-dimensional relationship between detection performance and the EEG spectrum confirms quantitatively the intuitive assumption that minute-scale changes in behavioral alertness during drowsiness are predominantly linked to changes in global brain dynamics along a single dimension of psychophysiological arousal.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Borghini, G., Astolfi, L., Vecchiato, G., Mattia, D., & Babiloni, F. (2014) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2012.10.003 · Cited by 1,331
Sleep Deprivation and Vigilant Attention
Lim, J., & Dinges, D. F. (2008) · Annals of the New York Academy of Sciences · doi:10.1196/annals.1417.002 · Cited by 1,213
A critical review of the psychophysiology of driver fatigue
Lal, S. K. L., & Craig, A. (2001) · Biological Psychology · doi:10.1016/s0301-0511(00)00085-5 · Cited by 1,001
Vigilance, alertness, or sustained attention: physiological basis and measurement
Oken, B. S., Salinsky, M. C., & Elsas, S. M. (2006) · Clinical Neurophysiology · doi:10.1016/j.clinph.2006.01.017 · Cited by 887
Driver fatigue: Electroencephalography and psychological assessment
Lal, S. K. L., & Craig, A. (2002) · Psychophysiology · doi:10.1017/s0048577201393095 · Cited by 533
The roles of cortical oscillations in sustained attention
Clayton, M. S., Yeung, N., & Cohen Kadosh, R. (2015) · Trends in Cognitive Sciences · doi:10.1016/j.tics.2015.02.004 · Cited by 533
Pupillometry and P3 index the locus coeruleus-noradrenergic arousal function in humans
Murphy, P. R., Robertson, I. H., Balsters, J. H., & O'connell, R. G. (2011) · Psychophysiology · doi:10.1111/j.1469-8986.2011.01226.x · Cited by 519
Sadaghiani, S., Scheeringa, R., Lehongre, K., Morillon, B., Giraud, A.-L., & Kleinschmidt, A. (2010) · The Journal of Neuroscience · doi:10.1523/jneurosci.1004-10.2010 · Cited by 504
Estimating alertness from the EEG power spectrum
Jung, T.-P., Makeig, S., Stensmo, M., & Sejnowski, T. J. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.553713 · Cited by 480
Self-citationBerka, C., Levendowski, D. J., Cvetinovic, M. M., Petrovic, M. M., Davis, G., Lumicao, M. N., Zivkovic, V. T., Popovic, M. V., & Olmstead, R. (2004) · International Journal of Human-Computer Interaction · doi:10.1207/s15327590ijhc1702_3 · Cited by 388
WILLIAMS, L. M., SIMMS, E., CLARK, C. R., PAUL, R. H., ROWE, D., & GORDON, E. (2005) · International Journal of Neuroscience · doi:10.1080/00207450590958475 · Cited by 293
Neurophysiological indices of strategy development and skill acquisition
Smith, M. E., McEvoy, L. K., & Gevins, A. (1999) · Cognitive Brain Research · doi:10.1016/s0926-6410(98)00043-3 · Cited by 284
A Real-Time Wireless Brain–Computer Interface System for Drowsiness Detection
Lin, C.-T., Chang, C.-J., Lin, B.-S., Hung, S.-H., Chao, C.-F., & Wang, I.-J. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2046415 · Cited by 282
EEG Signatures of Dynamic Functional Network Connectivity States
Allen, E. A., Damaraju, E., Eichele, T., Wu, L., & Calhoun, V. D. (2018) · Brain Topography · doi:10.1007/s10548-017-0546-2 · Cited by 259
Test–retest reliability of cognitive EEG
McEvoy, L. K., Smith, M. E., & Gevins, A. (2000) · Clinical Neurophysiology · doi:10.1016/s1388-2457(99)00258-8 · Cited by 184
Noninvasive Neural Prostheses Using Mobile and Wireless EEG
Lin, C.-T., Ko, L.-W., Chiou, J.-C., Duann, J.-R., Huang, R.-S., Liang, S.-F., Chiu, T.-W., & Jung, T.-P. (2008) · Proceedings of the IEEE · doi:10.1109/jproc.2008.922561 · Cited by 160
“The time series of recorded behavior data (driving performance) and EEG signals were smoothed using a causal 90-s square moving-averaged filter advancing at 2-s steps to eliminate variance at cycle lengths shorter than 1–2 min since driving performance becomes erratic at cycle lengths of 4m in and longer [8], [ 9 ].”
MethodSelf-citationThe impact of moderate sleep loss on neurophysiologic signals during working-memory task performance
Smith, M. E., McEvoy, L. K., & Gevins, A. (2002) · Sleep · doi:10.1093/sleep/25.7.56 · Cited by 157
Metadata
- Authors
- Makeig, S., & Jung, T.-P.
- Venue
- NeuroReport
- Published
- 1995-12
- Volume
- 7
- Issue
- 1
- Pages
- 213-216
- ISSN
- 0959-4965 (ISSN-L)
- OpenAlex
- W1971331662
- Cited by
- 229
- References
- 0
- FWCI
- 2.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.