Positron Emission Tomography Metabolic Data Corrected for Cortical Atrophy Using Magnetic Resonance Imaging
The DOI matches its Crossref record.
Abstract
The correct interpretation of clinical positron emission tomography (PET) data depends largely on the physical limits of the PET scanner. The partial volume effect (PVE) is related to the size of the studied object compared to the spatial resolution. It represents one of the most important limiting factors in quantitative data analysis. This effect is increased in the case of atrophy, as in patients with Alzheimer disease (AD), and it influences measurement of the metabolic reduction generally seen in cerebral degeneration. In this case, interpretation can be biased, because cortical activity will be underestimated due to the atrophy. In general, anatomical images of AD patients have shown diffuse atrophy, while PET studies have found widespread hypometabolism affecting the parietal and temporal lobes. Although hypometabolic areas usually correspond to atrophic regions, they also occur without such changes. Thus, the aim is to differentiate authentic hypometabolism (decrease of glucose consumption per unit volume of gray matter) from that due to PVE from atrophy (cell loss). Consequently, we are using a method for three-dimensional (3D) correction of human PET data with 3D magnetic resonance imaging (MRI). We measured atrophy and metabolism by using both T1-weighted MR images and high and medium resolution PET scans. We injected 12 patients and controls with [18F]fluorodeoxyglucose for glucose consumption measurements. Atrophy was estimated in the following way. We isolated the cerebral structures, using a segmentation technique on the MRI scans, into gray matter (GM), white matter, and cerebrospinal fluid. We superimposed the PET images onto the MR images to obtain anatomo-functional correlations. We degraded the segmented MR images to the resolution of the PET images by a convolution process to create a PET image correction map. We corrected the metabolic PET data for the PVE. We studied the cerebral metabolic rate of glucose in the GM where metabolic variation is the most relevant to AD. By dealing with problems relating to the sensitivity to the segmentation and to the PET-MRI coregistration, computation of MRI convolution processes provided the degree of PVE on a pixel-by-pixel basis, allowing correction of hypometabolisms contained in GM PET values. Global cortical metabolism increased after correction for PVE by, on average, 29 and 24% for tomographs acquired with medium (TTV03 LETI) and high (ECAT 953B CTI/Siemens) resolution, respectively, whereas the cortical metabolism increased by 75 and 65% for the respective tomographs in AD patients. The difference of metabolism between scans after correction for PVE was less than before correction, decreasing from 31 to 17%. This difference was most marked in the frontal and temporal lobes. Fusion imaging allowed correction for PVE in metabolic data using 3D MRI and determination of whether a change in the apparent radiotracer concentration in PET data reflected an alteration in GM volume, a change in radiotracer concentration per unit volume of GM, or both.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Partial-Volume Effect in PET Tumor Imaging
Soret, M., Bacharach, S. L., & Buvat, I. (2007) · Journal of Nuclear Medicine · doi:10.2967/jnumed.106.035774 · Cited by 1,549
Age differences in the frontal lateralization of verbal and spatial working memory revealed by PET
Reuter-Lorenz, P. A., Jonides, J., Smith, E. E., Hartley, A., Miller, A., Marshuetz, C., & Koeppe, R. A. (2000) · Journal of Cognitive Neuroscience · doi:10.1162/089892900561814 · Cited by 998
Mawlawi, O., Martinez, D., Slifstein, M., Broft, A., Chatterjee, R., Hwang, D.-R., Huang, Y., Simpson, N., Ngo, K., Van Heertum, R., et al. (2001) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-200109000-00002 · Cited by 525
“At one extreme, regions can be defined in terms of tissue classes (gray, white, CSF) (Meltzer et al., 1990, 1999; Muller-Gartner et al., 1992; Labbe et al., 1996).”
BackgroundResolution modeling in PET imaging: Theory, practice, benefits, and pitfalls
Rahmim, A., Qi, J., & Sossi, V. (2013) · Medical Physics · doi:10.1118/1.4800806 · Cited by 357
Thompson, P. M., Woods, R. P., Mega, M. S., & Toga, A. W. (2000) · Human Brain Mapping · doi:10.1002/(sici)1097-0193(200002)9:2<81::aid-hbm3>3.0.co;2-8 · Cited by 336
Metadata
- Authors
- Labbé, C., Froment, J. C., Kennedy, A., Ashburner, J., & Cinotti, L.
- Venue
- Alzheimer Disease & Associated Disorders
- Published
- 1996
- Volume
- 10
- Issue
- 3
- Pages
- 141-170
- ISSN
- 0893-0341 (ISSN-L)
- OpenAlex
- W2007257964
- Cited by
- 99
- References
- 0
- FWCI
- 5.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Positron Emission Tomography Metabolic Data Corrected for Cortical Atrophy Using Magnetic Resonance Imaging. https://app.cochat.ai/papers/10.1097/00002093-199601030-00005
- The paper
- Labbé, C., Froment, J. C., Kennedy, A., Ashburner, J., & Cinotti, L. (1996). Positron Emission Tomography Metabolic Data Corrected for Cortical Atrophy Using Magnetic Resonance Imaging. Alzheimer Disease & Associated Disorders. https://doi.org/10.1097/00002093-199601030-00005
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.