Prevention and Control of Bacterial Infections Associated with Medical Devices
Abstract
Bacteria that grow in association with medical devices always form slime enclosed biofilms, within which they are protected, to a large extent, from the bactericidal activity of chemical biocides and antibiotics. Mature biofilms (> 7 days) are demonstrably resistant to 500-5,000 times the concentrations of these agents than are necessary to kill free floating (planktonic) cells of the same organism. The authors have discovered that this well established inherent resistance of biofilm bacteria to antibacterial agents can be completely obviated if these agents are applied to these adherent populations within an electric field. The killing of biofilm bacteria by antibiotics can be dramatically enhanced by relatively weak electric fields (1.5 V/cm and 15 microA/cm2) that, in themselves, have no deleterious effects on these slime protected populations adherent to plastic or metal surfaces. This bioelectric technology can readily be used to enhance the preimplantation sterilization of medical devices by biocides. The authors suggest that it may also be used to control biofilm formation and consequent infection by electrically enhanced perioperative antibiotic prophylaxis and by electrically enhanced penetration of antibiotics to kill the biofilm bacteria that form the inherently resistant nidus of chronic device related infections.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bacterial Biofilms: A Common Cause of Persistent Infections
Costerton, J. W., Stewart, P. S., & Greenberg, E. P. (1999) · Science · doi:10.1126/science.284.5418.1318 · Cited by 12,167
Self-citationThe Involvement of Cell-to-Cell Signals in the Development of a Bacterial Biofilm
Davies, D. G., Parsek, M. R., Pearson, J. P., Iglewski, B. H., Costerton, J. W., & Greenberg, E. P. (1998) · Science · doi:10.1126/science.280.5361.295 · Cited by 3,396
Self-citationCarboxymethyl chitosan: Properties and biomedical applications
Shariatinia, Z. (2018) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2018.09.131 · Cited by 777
The application of biofilm science to the study and control of chronic bacterial infections
Costerton, W. J., Veeh, R., Shirtliff, M. E., Pasmore, M. E., Post, C., & Ehrlich, G. D. (2003) · Journal of Clinical Investigation · doi:10.1172/jci20365 · Cited by 649
The application of biofilm science to the study and control of chronic bacterial infections
Costerton, W., Veeh, R., Shirtliff, M., Pasmore, M., Post, C., & Ehrlich, G. (2003) · Journal of Clinical Investigation · doi:10.1172/jci200320365 · Cited by 630
Metadata
- Authors
- KHOURY, A. E., LAM, K., ELLIS, B., & COSTERTON, J. W.
- Venue
- ASAIO Journal
- Published
- 1992-07
- Volume
- 38
- Issue
- 3
- Pages
- M174-M178
- ISSN
- 1058-2916 (ISSN-L)
- OpenAlex
- W1981979777
- Cited by
- 264
- References
- 0
- FWCI
- 1.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Prevention and Control of Bacterial Infections Associated with Medical Devices. https://app.cochat.ai/papers/10.1097/00002480-199207000-00013
- The paper
- KHOURY, A. E., LAM, K., ELLIS, B., & COSTERTON, J. W. (1992). Prevention and Control of Bacterial Infections Associated with Medical Devices. ASAIO Journal. https://doi.org/10.1097/00002480-199207000-00013
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.