Intervention Based on Monthly Monitoring Decreases Hemodialysis Access Thrombosis
The DOI matches its Crossref record.
Abstract
We randomized 103 patients (68 arteriovenous [AV] fistulas, 35 polytetrafluoroethylene [PTFE] grafts; mean follow-up 197 days) to monthly measurement of access flow (QAT), monthly measurement of static venous pressure (VPS), or no monthly monitoring (control patients) to determine whether access thrombosis would decrease. Patients with access flow <750 cc/min or with static venous pressure > or =0.5 were referred for angiography and angioplasty of stenotic lesions > or =50%. Six of sixty-two (9.7%) of monthly monitored patients (MM) developed access thrombosis vs. 9 of 41 (22%) of control patients (p<0.05). Fewer MM patients developed thrombosis in AV fistulas (2.4% [2 of 42] vs. 15.4% [4 of 26] control patients; p<0.05). Monthly monitored patients had fewer thrombotic episodes than control patients (19 vs. 125 per 100 patient-years; p<0.01). Thrombosis rates were lowest in patients receiving monthly access flow measurement (5.9 [QAT] vs. 30.3 per 100 patient-years [VPS]; p<0.05). In conclusion, intervention based on monthly access flow measurement or static venous pressure decreased hemodialysis access thrombosis. Measurement of access flow tended to result in lower thrombosis rates than after static venous pressure. We believe that monthly access flow measurement will ensure the lowest incidence of thrombosis and decrease the cost of access maintenance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Tordoir, J., Canaud, B., Haage, P., Konner, K., Basci, A., Fouque, D., Kooman, J., Martin-Malo, A., Pedrini, L., Pizzarelli, F., et al. (2007) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfm021 · Cited by 645
Smart, N. A., Dieberg, G., Ladhani, M., & Titus, T. (2014) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd007333.pub2 · Cited by 240
Guía Clínica Española del Acceso Vascular para Hemodiálisis
Ibeas, J., Roca-Tey, R., Vallespín, J., Moreno, T., Moñux, G., Martí-Monrós, A., del Pozo, J. L., Gruss, E., Ramírez de Arellano, M., Fontseré, N., et al. (2017) · Nefrología · doi:10.1016/j.nefro.2017.11.004 · Cited by 214
Moist, L. M., Churchill, D. N., House, A. A., Millward, S. F., Elliott, J. E., Kribs, S. W., DeYoung, W. J., Blythe, L., Stitt, L. W., & Lindsay, R. M. (2003) · Journal of the American Society of Nephrology · doi:10.1097/01.asn.0000089562.98338.60 · Cited by 212
Kukita, K., Ohira, S., Amano, I., Naito, H., Azuma, N., Ikeda, K., Kanno, Y., Satou, T., Sakai, S., Sugimoto, T., et al. (2015) · Therapeutic Apheresis and Dialysis · doi:10.1111/1744-9987.12296 · Cited by 211
Metadata
- Authors
- SANDS, J. J., JARYAC, P. A., MIRANDA, C. L., & KAPSICK, B. J.
- Venue
- ASAIO Journal
- Published
- 1999-05
- Volume
- 45
- Issue
- 3
- Pages
- 147-150
- ISSN
- 1058-2916 (ISSN-L)
- OpenAlex
- W2086664618
- Cited by
- 136
- References
- 0
- FWCI
- 13.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Intervention Based on Monthly Monitoring Decreases Hemodialysis Access Thrombosis. https://app.cochat.ai/papers/10.1097/00002480-199905000-00008
- The paper
- SANDS, J. J., JARYAC, P. A., MIRANDA, C. L., & KAPSICK, B. J. (1999). Intervention Based on Monthly Monitoring Decreases Hemodialysis Access Thrombosis. ASAIO Journal. https://doi.org/10.1097/00002480-199905000-00008
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.