Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 212

The DOI matches its Crossref record.

Regular Monitoring of Access Flow Compared with Monitoring of Venous Pressure Fails to Improve Graft Survival

Moist, Louise M., Churchill, David N., House, Andrew A., Millward, Steven F., Elliott, James E., Kribs, Stewart W., DeYoung, William J., Blythe, Lesley, Stitt, Lawrence W., Lindsay, Robert M.·2003·Journal of the American Society of Nephrology

Abstract

Regular vascular access blood flow (Qa) surveillance is recommended to detect graft stenosis; however, there is little evidence that monitoring and correcting with angioplasty improves graft survival. This blinded, randomized, controlled trial of 112 patients studied time to graft thrombosis and graft loss, comparing monthly Qa plus standard surveillance (dynamic venous pressure and physical examination) (treatment group) to standard surveillance alone (control group). Only the treatment group was referred for angiogram if Qa <650 ml/min or a 20% decrease in Qa from baseline. Percutaneous angioplasty was performed for stenosis >50%. The rate of graft thrombosis per patient-year at risk was 0.41 and 0.51 in the control and treatment groups, respectively. Fifty-one interventions (0.93/patient-years at risk) were performed in the treatment group versus 31 interventions (0.61/patient-years at risk) in the control group. There was no difference in time to graft loss (P = 0.890). In a multivariate analysis, aspirin (ASA) therapy at baseline was associated with an 84% reduction in risk of graft thrombosis (odds ratio [OR], 0.14; P = 0.002). Higher baseline Qa (OR, 0.84; P = 0.05) and longer interval since graft insertion (OR, 0.97; P = 0.07) were associated with a decrease in graft thrombosis. Results reveal that graft surveillance that uses Qa increases the detection of stenosis, compared with standard surveillance; however, intervention with angioplasty does not improve the time to graft thrombosis or time to graft loss.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/01.asn.0000089562.98338.60

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 212

Metadata

Authors
Moist, L. M., Churchill, D. N., House, A. A., Millward, S. F., Elliott, J. E., Kribs, S. W., DeYoung, W. J., Blythe, L., Stitt, L. W., & Lindsay, R. M.
Venue
Journal of the American Society of Nephrology
Published
2003-10
Volume
14
Issue
10
Pages
2645-2653
ISSN
1046-6673 (ISSN-L)
OpenAlex
W2123803594
Cited by
212
References
0
FWCI
24.80
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Regular Monitoring of Access Flow Compared with Monitoring of Venous Pressure Fails to Improve Graft Survival. https://app.cochat.ai/papers/10.1097/01.asn.0000089562.98338.60
The paper
Moist, L. M., Churchill, D. N., House, A. A., Millward, S. F., Elliott, J. E., Kribs, S. W., DeYoung, W. J., Blythe, L., Stitt, L. W., & Lindsay, R. M. (2003). Regular Monitoring of Access Flow Compared with Monitoring of Venous Pressure Fails to Improve Graft Survival. Journal of the American Society of Nephrology. https://doi.org/10.1097/01.asn.0000089562.98338.60

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.