Assessment of Chronically Implanted Subcutaneous Glucose Sensors in Dogs: The Effect of Surrounding Fluid Masses
The DOI matches its Crossref record.
Abstract
We developed a continuous, distributed-anode glucose sensor and now report on its use during subcutaneous implantation in dogs without diabetes. Using telemetry, we monitored sensor response to weekly administration of intravenous glucose. In a preliminary attempt to reduce fibrosis around the sensor, some sensors were designed to slowly release dexamethasone (DEX). Before implantation, in vitro sensor sensitivity was similar to values obtained after explantation (0.66 +/- 0.09 vs 1.07 +/- 0.19 nA/mM, n = 9, p = ns). Sensitivity in individual animals varied substantially over time. Average longevity of sensors was 32.1 +/- 8.6 days. Device failure was caused by leakage of fluid into, or interruption of, circuitry. Lag time during glucose ascent averaged 5.8 +/- 1.0 min. In devices that became surrounded by fluid masses, lag time during descent was greater than in devices without fluid (33.7 +/- 4.5 vs 10.7 +/- 1.6 min, p < 0.001). There was a nonsignificant tendency for longevity of the six sensors that contained DEX to be greater than the eight sensors without DEX (47.2 +/- 18.7 vs 20.8 +/- 3.6 days, p = ns). The development of fluid masses surrounding electrochemical glucose sensors prolongs lag time and probably contributes to the commonly observed instability of sensitivity over time. In future long-term implant studies, it is likely that avoidance of fluid masses will improve sensor function.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Electrochemical Glucose Sensors and Their Applications in Diabetes Management
Heller, A., & Feldman, B. (2008) · Chemical Reviews · doi:10.1021/cr068069y · Cited by 1,707
Drug/device combinations for local drug therapies and infection prophylaxis
Wu, P., & Grainger, D. W. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.11.031 · Cited by 491
“[202] Ward WK, Troupe JE.”
BackgroundBiocompatible Materials for Continuous Glucose Monitoring Devices
Nichols, S. P., Koh, A., Storm, W. L., Shin, J. H., & Schoenfisch, M. H. (2013) · Chemical Reviews · doi:10.1021/cr300387j · Cited by 347
Ward, W. K. (2008) · Journal of Diabetes Science and Technology · doi:10.1177/193229680800200504 · Cited by 325
Self-citationEmerging biomedical sensing technologies and their applications
Cote, G. L., Lec, R. M., & Pishko, M. V. (2003) · IEEE Sensors Journal · doi:10.1109/jsen.2003.814656 · Cited by 180
“Accurate real-time monitoring in the clinical setting requires frequent recalibration of the in vivo sensor using an external glucose measurement reference method [3].”
Method
Metadata
- Authors
- WARD, W. K., & TROUPE, J. E.
- Venue
- ASAIO Journal
- Published
- 1999-11
- Volume
- 45
- Issue
- 6
- Pages
- 555-561
- ISSN
- 1058-2916 (ISSN-L)
- OpenAlex
- W1984750665
- Cited by
- 43
- References
- 0
- FWCI
- 2.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Assessment of Chronically Implanted Subcutaneous Glucose Sensors in Dogs: The Effect of Surrounding Fluid Masses. https://app.cochat.ai/papers/10.1097/00002480-199911000-00009
- The paper
- WARD, W. K., & TROUPE, J. E. (1999). Assessment of Chronically Implanted Subcutaneous Glucose Sensors in Dogs: The Effect of Surrounding Fluid Masses. ASAIO Journal. https://doi.org/10.1097/00002480-199911000-00009
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.