Safety Observations in Phase I Clinical Evaluation of the Excorp Medical Bioartificial Liver Support System after the First Four Patients
The DOI matches its Crossref record.
Abstract
A Phase I clinical safety evaluation of the Excorp Medical, Inc, Bioartificial Liver Support System (BLSS) is in progress. Inclusion criteria are patients with acute liver failure of any etiology, presenting with encephalopathy deteriorating beyond Parson's Grade 2. The BLSS consists of a blood pump, heat exchanger to control blood temperature, oxygenator to control oxygenation and pH, bioreactor, and associated pressure and flow alarm systems. Patient liver support is provided by 70-100 g of porcine liver cells housed in the hollow fiber bioreactor. A single support period evaluation consists of 12 hour extracorporeal perfusion with the BLSS sandwiched between 12 hours of pre (baseline) and 12 hours of post support monitoring. Blood chemistries and hematologies are obtained every 6 hours during monitoring periods and every 4 hours during perfusion. Physiologic parameters are monitored continuously. The patient may receive a second treatment at the discretion of the clinical physician. Preliminary evaluation of safety considerations after enrollment of the first four patients (F, 41, acetaminophen induced, two support periods; M, 50, Wilson's disease, one support period; F, 53, acute alcoholic hepatitis, two support periods; F, 24, chemotherapy induced, one support period) is presented. All patients tolerated the extracorporeal perfusion well. All patients presented with hypoglycemia at the start of perfusion, treatable by IV dextrose. Transient hypotension at the start of perfusion responded to an IV fluid bolus. Only the second patient required heparin anticoagulation. No serious or unexpected adverse events were noted. Moderate biochemical response to support was noted in all patients. Completion of the Phase I safety evaluation is required to fully characterize the safety of the BLSS.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Acute liver failure: Summary of a workshop†
Lee, W. M., Squires, R. H., Nyberg, S. L., Doo, E., & Hoofnagle, J. H. (2008) · Hepatology · doi:10.1002/hep.22177 · Cited by 757
Artificial and bioartificial liver devices: present and future
Carpentier, B., Gautier, A., & Legallais, C. (2009) · Gut · doi:10.1136/gut.2008.175380 · Cited by 213
Clinical Application of Bioartificial Liver Support Systems
van de Kerkhove, M. P., Hoekstra, R., Chamuleau, R. A. F. M., & van Gulik, T. M. (2004) · Annals of Surgery · doi:10.1097/01.sla.0000132986.75257.19 · Cited by 210
“Four patients were treated with the BLSS in a phase I clinical trial.(81) Causes of ALF in this group were acetaminophen intoxication, Wilson disease, acute alcoholic hepatitis, and chemotherapy.”
MethodPfeiffer, R. (2007) · Seminars in Neurology · doi:10.1055/s-2007-971173 · Cited by 196
Wang, Y., Zheng, Q., Sun, Z., Wang, C., Cen, J., Zhang, X., Jin, Y., Wu, B., Yan, T., Wang, Z., et al. (2023) · Cell Stem Cell · doi:10.1016/j.stem.2023.03.013 · Cited by 55
Metadata
- Authors
- Mazariegos, G. V., Kramer, D. J., Lopez, R. C., Obaid Shakil, A., Rosenbloom, A. J., DeVera, M., Giraldo, M., Grogan, T. A., Zhu, Y., Fulmer, M. L., Amiot, B. P., & Patzer, J. F.
- Venue
- ASAIO Journal
- Published
- 2001-09
- Volume
- 47
- Issue
- 5
- Pages
- 471-475
- ISSN
- 1058-2916 (ISSN-L)
- OpenAlex
- W2072993053
- Cited by
- 116
- References
- 0
- FWCI
- 8.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Safety Observations in Phase I Clinical Evaluation of the Excorp Medical Bioartificial Liver Support System after the First Four Patients. https://app.cochat.ai/papers/10.1097/00002480-200109000-00015
- The paper
- Mazariegos, G. V., Kramer, D. J., Lopez, R. C., Obaid Shakil, A., Rosenbloom, A. J., DeVera, M., Giraldo, M., Grogan, T. A., Zhu, Y., Fulmer, M. L., Amiot, B. P., & Patzer, J. F. (2001). Safety Observations in Phase I Clinical Evaluation of the Excorp Medical Bioartificial Liver Support System after the First Four Patients. ASAIO Journal. https://doi.org/10.1097/00002480-200109000-00015
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.