Artificial and bioartificial liver devices: present and future
Abstract
Liver failure is associated with high morbidity and mortality without transplantation. There are two types of device for temporary support: artificial and bioartificial livers. Artificial livers essentially use non-living components to remove the toxins accumulated during liver failure. Bioartificial livers have bioreactors containing hepatocytes to provide both biotransformation and synthetic liver functions. We review here the operating principles, chemical effects, clinical effects and complications of both types, with specific attention paid to bioartificial systems. Several artificial support systems have FDA marketing authorisation or are CE labelled, but the improvement they provide in terms of patient clinical outcome has not yet been fully demonstrated. At present, different bioartifical systems are being investigated clinically on the basis of their promises and capacity to provide and replace most liver functions. However, important issues such as cost, cell availability, maintenance of cell viability and functionality throughout treatment, and regulatory issues, as well as difficult challenges, including implementing cell-housing devices at the patient’s bedside on an emergency basis, have delayed their appearance in intensive care units and on the market. Bioreactors are, nevertheless, when combined with artificial components, a pragmatic approach for future treatment of liver failure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Acute-on chronic liver failure
Jalan, R., Gines, P., Olson, J. C., Mookerjee, R. P., Moreau, R., Garcia-Tsao, G., Arroyo, V., & Kamath, P. S. (2012) · Journal of Hepatology · doi:10.1016/j.jhep.2012.06.026 · Cited by 646
Direct Reprogramming of Human Fibroblasts to Functional and Expandable Hepatocytes
Huang, P., Zhang, L., Gao, Y., He, Z., Yao, D., Wu, Z., Cen, J., Chen, X., Liu, C., Hu, Y., et al. (2014) · Cell Stem Cell · doi:10.1016/j.stem.2014.01.003 · Cited by 560
The therapeutic potential of mesenchymal stem cell‐derived extracellular vesicles
Katsuda, T., Kosaka, N., Takeshita, F., & Ochiya, T. (2013) · PROTEOMICS · doi:10.1002/pmic.201200373 · Cited by 423
Kribben, A., Gerken, G., Haag, S., Herget–Rosenthal, S., Treichel, U., Betz, C., Sarrazin, C., Hoste, E., Van Vlierberghe, H., Escorsell, À., et al. (2012) · Gastroenterology · doi:10.1053/j.gastro.2011.12.056 · Cited by 409
Acute-on-chronic liver failure
Bernal, W., Jalan, R., Quaglia, A., Simpson, K., Wendon, J., & Burroughs, A. (2015) · The Lancet · doi:10.1016/s0140-6736(15)00309-8 · Cited by 331
Metadata
- Authors
- Carpentier, B., Gautier, A., & Legallais, C.
- Venue
- Gut
- Publisher
- BMJ
- Published
- 2009-11-18
- Volume
- 58
- Issue
- 12
- Pages
- 1690-1702
- ISSN
- 0017-5749 (ISSN-L)
- 1468-3288
- OpenAlex
- W2103862050
- Cited by
- 213
- References
- 0
- FWCI
- 16.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Artificial and bioartificial liver devices: present and future. https://app.cochat.ai/papers/10.1136/gut.2008.175380
- The paper
- Carpentier, B., Gautier, A., & Legallais, C. (2009). Artificial and bioartificial liver devices: present and future. Gut. https://doi.org/10.1136/gut.2008.175380
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.