Split Renal Function Testing Using Tc-99m DTPA: A Rapid Technique for Determining Differential Glomerular Filtration

GATES, GARY F. · 1983 · Clinical Nuclear Medicine

Abstract

The fractional renal uptake of intravenously administered Tc-99m DTPA, within 2 to 3 minutes following radiotracer arrival in the kidneys, is proportional to the glomerular filtration rate (GFR). Thus it is possible to determine total, as well as individual kidney, GFR by a radionuclide technique which needs only six minutes of patient time and requires neither blood nor urine samples. The radionuclide computed GFR correlates extremely well with 24-hour creatinine clearance determinations, and is highly reproducible. This method has been used in nearly 500 split renal function determinations and has provided valuable, accurate information.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00003072-198309000-00003

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 194

Metadata

Authors
GATES, G. F.
Venue
Clinical Nuclear Medicine
Published
1983-09
Volume
8
Issue
9
Pages
400-407
ISSN
0363-9762 (ISSN-L)
OpenAlex
W2006090662
Cited by
194
References
0
FWCI
3.07
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Split Renal Function Testing Using Tc-99m DTPA: A Rapid Technique for Determining Differential Glomerular Filtration. https://app.cochat.ai/papers/10.1097/00003072-198309000-00003
The paper
GATES, G. F. (1983). Split Renal Function Testing Using Tc-99m DTPA: A Rapid Technique for Determining Differential Glomerular Filtration. Clinical Nuclear Medicine. https://doi.org/10.1097/00003072-198309000-00003

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.