CoChat

Collecting and Analyzing Cord Blood Gases

RILEY, RICHARD J., JOHNSON, JOHN W. C. · 1993 · Clinical Obstetrics and Gynecology
Cited by 116

The DOI matches its Crossref record.

Abstract

The analysis of cord blood respiratory gases and acid-base values is an important adjunct for determining the extent and cause of fetal acidosis at delivery. Although the quality and reliability of the blood gas instruments have improved dramatically, constant vigilance still is required and mandated to ensure accurate and precise results. Failure to control the many sampling and analysis variables that affect cord blood gas results will limit their usefulness. Most preanalytic problems become a minor concern when the blood gas analyses are done within a few minutes after obtaining the sample. Comparison of data among centers requires, not only that reference ranges be stated, but also that various corrections or factors that were used to adjust the results be described. Perhaps, a consensus could be reached to establish the optimal method of collection and the best methods for analyzing and reporting the results from cord blood gas and acid-base studies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00003081-199303000-00005

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 116

Metadata

Authors
RILEY, R. J., & JOHNSON, J. W. C.
Venue
Clinical Obstetrics and Gynecology
Published
1993-03
Volume
36
Issue
1
Pages
13-23
ISSN
0009-9201 (ISSN-L)
OpenAlex
W2087313594
Cited by
116
References
0
FWCI
1.87
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Collecting and Analyzing Cord Blood Gases. https://app.cochat.ai/papers/10.1097/00003081-199303000-00005
The paper
RILEY, R. J., & JOHNSON, J. W. C. (1993). Collecting and Analyzing Cord Blood Gases. Clinical Obstetrics and Gynecology. https://doi.org/10.1097/00003081-199303000-00005

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.