The DOI matches its Crossref record.
Functional Walking in Paralyzed Patients by Means of Electrical Stimulation
Abstract
Three partially paralyzed patients were unable to walk even after maximal rehabilitation attempts at a major rehabilitation center. One 36-year-old man had transverse myelitis, a 57-year-old man had had a stroke, and the third patient, a 35-year-old man, had incurred a traumatic brain injury. The three patients were unable to flex the hips, had adductor spasm and weak hip and knee extension, and lacked ankle dorsiflexion. Intramuscular stainless steel wire electrodes activated by timers were placed in the quadriceps, hip flexors, extensors, and abductors, as needed. Muscle force and foot contact evaluations were done using the Cybex and the Cleveland Veterans Administration Gait Laboratory. After implantation of intramuscular electrodes, all three patients had improved function but still desired some supervision in walking. A ten-fold increase in knee torque was noted in one patient, thereby providing him with nearly normal strength. No implant complications were noted. The study demonstrated the feasibility of functional neuromuscular stimulation (FNS) gait augmentation in a previously nonwalking patient outside the laboratory. Further improvements will require the development of an implantable, multichannel, programmable microprocessor-controlled stimulator.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Neuromuscular electrical stimulation for muscle weakness in adults with advanced disease
Jones, S., Man, W. D.-C., Gao, W., Higginson, I. J., Wilcock, A., & Maddocks, M. (2016) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd009419.pub3 · Cited by 292
Implanted stimulators for restoration of function in spinal cord injury
Bhadra, N., Kilgore, K. L., & Peckham, P. H. (2001) · Medical Engineering & Physics · doi:10.1016/s1350-4533(01)00012-1 · Cited by 92
Peripheral nerve stimulation for restoration of motor function
Bhadra, N., & Peckham, P. H. (1997) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199709000-00004 · Cited by 80
Schiefer, M. A., Freeberg, M., Pinault, G. J. C., Anderson, J., Hoyen, H., Tyler, D. J., & Triolo, R. J. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/5/056006 · Cited by 57
“from SCI [11–14] or stroke [15–17].”
The design of and chronic tissue response to a composite nerve electrode with patterned stiffness
Freeberg, M. J., Stone, M. A., Triolo, R. J., & Tyler, D. J. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa6632 · Cited by 54
Metadata
- Authors
- MARSOLAIS, E. B., & KOBETIC, R.
- Venue
- Clinical Orthopaedics and Related Research
- Published
- 1983-05
- Volume
- 175
- Issue
- 175
- Pages
- 30-36
- ISSN
- 0009-921X (ISSN-L)
- OpenAlex
- W2036239045
- Cited by
- 165
- References
- 0
- FWCI
- 6.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Functional Walking in Paralyzed Patients by Means of Electrical Stimulation. https://app.cochat.ai/papers/10.1097/00003086-198305000-00005
- The paper
- MARSOLAIS, E. B., & KOBETIC, R. (1983). Functional Walking in Paralyzed Patients by Means of Electrical Stimulation. Clinical Orthopaedics and Related Research. https://doi.org/10.1097/00003086-198305000-00005
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.