Implanted stimulators for restoration of function in spinal cord injury
Abstract
Neuroprostheses that electrically stimulate paralyzed muscles provide functional enhancements for individuals with spinal cord injury and stroke such as standing and stepping, reaching and grasping, and bladder and bowel function. For chronic applications, implanted neuroprostheses lead to reliable, low-maintenance and patient-acceptable systems. The advantages of such systems are discussed followed by a generic description of implantable stimulators. Features of current first and second generation neuroprostheses developed at our centre are discussed followed by our experience in the application of these devices in the rehabilitation of individuals with spinal cord injury.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Epimysial electrodes have proven their suitability in current complex motor prostheses that require coordinated stimulation of several muscles, for example, grasping system for tetraplegics (Freehand System) and standing and walking systems for paraplegics.
“Epimysial electrodes have proven their suitability in current complex motor prostheses that require coordinated stimulation of several muscles, for example, grasping system for tetraplegics (Freehand System) (Bhadra et al., 2001) and standing and walking systems for paraplegics”
From A critical review of interfaces with the peripheral nervous system for the control of neuroprostheses and hybrid bionic systems (2005) · cites this paper as Bhadra et al., 2001
Forces generated by stimulating two completely independent populations of motor units will add linearly, even if one population is stimulated while neurons from the other population are in their absolute refractory period.
“Conversely, the forces generated by stimulating two completely independent populations of motor units will add linearly, even if one population is stimulated while neurons from the other population are in their absolute refractory period [14].”
From Optimization of selective stimulation parameters for multi-contact electrodes (2013) · cites this paper as [14]
Motor units in their absolute refractory period, which lasts between 1.5 and 2.1 ms, will not respond to stimulation.
“Another method for quantifying selectivity takes advantage of the concept that motor units in their absolute refractory period, which lasts between 1.5 and 2.1 ms, will not respond to stimulation [1,3,6,11-15].”
From Optimization of selective stimulation parameters for multi-contact electrodes (2013) · cites this paper as [14]
Cites
Smith, B., Peckham, P. H., Keith, M. W., & Roscoe, D. D. (1987) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1987.325979 · Cited by 281 · see citing works
Self-citationSmith, B., Tang, Z., Johnson, M. W., Pourmehdi, S., Gazdik, M. M., Buckett, J. R., & Peckham, P. H. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.664202 · Cited by 270 · see citing works
Self-citationWuolle, K. S., Doren, C. L. V., Thrope, G. B., Keith, M. W., & Peckham, P. H. (1994) · The Journal Of Hand Surgery · doi:10.1016/0363-5023(94)90008-6 · Cited by 198 · see citing works
Self-citationAn Implanted Upper-Extremity Neuroprosthesis. Follow-up of Five Patients*
KILGORE, K. L., PECKHAM, P. H., KEITH, M. W., THROPE, G. B., WUOLLE, K. S., BRYDEN, A. M., & HART, R. L. (1997) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199704000-00008 · Cited by 192 · see citing works
Self-citationTang, Z., Smith, B., Schild, J. H., et al. (1995) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.376158 · Cited by 188 · see citing works
Functional Walking in Paralyzed Patients by Means of Electrical Stimulation
Marsolais, E. B., & Kobetic, R. (1983) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198305000-00005 · Cited by 166 · see citing works
Kobetic, R., Sharma, M., Triolo, R. J., Uhlir, J. P., Bieri, C., Wibowo, M., Polando, G., Marsolais, E. B., Davis, J. A., & Ferguson, K. A. (1999) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.808942 · Cited by 155 · see citing works
Synthesis of hand grasp using functional neuromuscular stimulation
Kilgore, K. L., Peckham, P. H., Thrope, G. B., Keith, M. W., & Gallaher-Stone, K. A. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.32109 · Cited by 152 · see citing works
Self-citationPeckham, P. H., Keith, M. W., & Freehafer, A. A. (1988) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-198870010-00027 · Cited by 136 · see citing works
Self-citationRecruitment properties of monopolar and bipolar epimysial electrodes
Grandjean, P. A., & Mortimer, J. T. (1986) · Annals of Biomedical Engineering · doi:10.1007/bf02364648 · Cited by 134 · see citing works
Crago, P. E., Peckham, P. H., Mortimer, J. T., & Van Der Meulen, J. P. (1974) · Annals of Biomedical Engineering · doi:10.1007/bf02368496 · Cited by 133 · see citing works
Self-citationTwenty Years of Experience in Phrenic Nerve Stimulation to Pace the Diaphragm
GLENN, W. W. L., PHELPS, M. L., ELEFTERLEADES, J. A., DENTZ, B., & HOGAN, J. F. (1986) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1986.tb06627.x · Cited by 125 · see citing works
Keith, M. W., Kilgore, K. L., Peckham, P. H., Wuolle, K. S., Creasey, G. H., & Lemay, M. A. (1996) · The Journal Of Hand Surgery · doi:10.1016/s0363-5023(96)80160-2 · Cited by 117 · see citing works
Self-citationImbalanced biphasic electrical stimulation: Muscle tissue damage
Scheiner, A., Mortimer, J. T., & Roessmann, U. (1990) · Annals of Biomedical Engineering · doi:10.1007/bf02364157 · Cited by 117 · see citing works
Functional Neuromuscular Stimulation Neuroprostheses for the Tetraplegic Hand
Keith, M. W., Peckham, P. H., Thrope, G. B., Buckett, J. R., Wuolle, K. S., & MENGER, V. (1988) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198808000-00005 · Cited by 115 · see citing works
Self-citationA surgically-implanted intramuscular electrode for an implantable neuromuscular stimulation system
Memberg, W. D., Peckham, P. H., & Keith, M. W. (1994) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.313149 · Cited by 111 · see citing works
Self-citationTriolo, R. J., Bieri, C., Uhlir, J., Kobetic, R., Scheiner, A., & Marsolais, E. B. (1996) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(96)90133-1 · Cited by 102 · see citing works
The first 500 sacral anterior root stimulators: implant failures and their repair
Brindley, G. S. (1995) · Spinal Cord · doi:10.1038/sc.1995.3 · Cited by 89 · see citing works
Electrical stimulation of sacral roots for micturition after spinal cord injury
Creasey, G. H. (1993) · Urologic Clinics of North America · doi:10.1016/s0094-0143(21)00511-5 · Cited by 80 · see citing works
Peripheral nerve stimulation for restoration of motor function
Bhadra, N., & Peckham, P. H. (1997) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199709000-00004 · Cited by 80 · see citing works
Self-citationEvaluation of shoulder movement as a command control source
Johnson, M. W., & Peckham, P. H. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.58598 · Cited by 74 · see citing works
Self-citationFunctional evaluation of quadriplegic patients using a hand neuroprosthesis.
Wijman, C. A. C., Wuolle, K. S., Doren, C. L. V., Thrope, G. B., Peckham, P. H., & Keith, M. W. (1990) · PubMed · Cited by 69 · see citing works
Self-citationSurgical Technique for Installing an Eight-Channel Neuroprosthesis for Standing
Davis, J. A., Triolo, R. J., Uhlir, J. P., Bhadra, N., Lissy, D. A., Nandurkar, S., & Marsolais, E. B. (2001) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-200104000-00035 · Cited by 68 · see citing works
Self-citationImplantable transducer for two-degree of freedom joint angle sensing
Johnson, M. W., Peckham, P. H., Bhadra, N., Kilgore, K. L., Gazdik, M. M., Keith, M. W., & Strojnik, P. (1999) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.788471 · Cited by 65 · see citing works
Self-citationSmith, B. T., Mulcahey, M. J., & Betz, R. R. (1996) · Spinal Cord · doi:10.1038/sc.1996.3 · Cited by 47 · see citing works
In-line lead connector for use with implanted neuroprosthesis
Letechipia, J., Peckham, P. H., Gazdik, M. M., & Smith, B. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.83572 · Cited by 47 · see citing works
Self-citationElectrode characterization for functional application to upper extremity FNS
Kilgore, K. L., Peckham, P. H., Keith, M. W., & Thrope, G. B. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.43606 · Cited by 40 · see citing works
Self-citationImplementation of an implantable joint-angle transducer.
Bhadra, N., Peckham, P. H., Keith, M. W., Kilgore, K. L., Montague, F. W., Gazdik, M. M., & Stage, T. G. (2002) · PubMed · Cited by 39 · see citing works
Self-citationImplantation of a 16-Channel Functional Electrical Stimulation Walking System
Sharma, M., Marsolais, E. B., Polando, G., Triolo, R. J., Davis, J. A., Bhadra, N., & Uhlir, J. P. (1998) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199802000-00029 · Cited by 36 · see citing works
Self-citationFunctional Neuromuscular Stimulation: Outcomes in Young People with Tetraplegia
Mulcahey, M. J., Smith, B. T., Betz, R., Triolo, R. J., & Peckham, P. H. (1994) · The Journal of The American Paraplegia Society · doi:10.1080/01952307.1994.11735912 · Cited by 36 · see citing works
Self-citationUpper extremity neuroprostheses using functional electrical stimulation.
Scott, T. R. D., Peckham, P. H., & Keith, M. W. (1995) · PubMed · Cited by 26 · see citing works
Self-citationPermanent Cardiac Assistance from Skeletal Muscle: A Prospect for the New Millennium
Salmons, S. (1999) · Artificial Organs · doi:10.1046/j.1525-1594.1999.06355.x · Cited by 15 · see citing works
Grandjean, P. A., Acker, M. G., Madoff, R. D., et al. (1996) · PubMed · Cited by 15 · see citing works
Restoration of Upper Extremity Function in Tetraplegia
Peckham, P. H., Keith, M. W., & Kilgore, K. L. (1999) · Topics in Spinal Cord Injury Rehabilitation · doi:10.1310/uckb-nvgc-g71t-hjew · Cited by 14 · see citing works
Self-citationMultichannel implantable stimulation and telemetry system for neuromuscular control
Tang, Z., & Peckham, P. H. (2002) · Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.1994.411963 · Cited by 9 · see citing works
Self-citation
Flagged first, then by citations
Cited by
Sorted by citations
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845 · see citing works
“Long-term stability of stimulating spiral nerve cuff electrodes on human peripheral nerves”
Christie, B. P., Freeberg, M., Memberg, W. D., Pinault, G. J. C., Hoyen, H. A., Tyler, D. J., & Triolo, R. J. (2017) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-017-0285-3 · Cited by 97 · see citing works
Fisher, L. E., Tyler, D. J., Anderson, J. S., & Triolo, R. J. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/4/046010 · Cited by 89 · see citing works
Standing After Spinal Cord Injury With Four-Contact Nerve-Cuff Electrodes for Quadriceps Stimulation
Fisher, L. E., Miller, M. E., Bailey, S. N., Davis Jr., J. A., Anderson, J. S., Rhode, L., Tyler, D. J., & Triolo, R. J. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2003390 · Cited by 90 · see citing works
Polymeric C-shaped cuff electrode for recording of peripheral nerve signal
Xue, N., Sun, T., Tsang, W. M., Delgado-Martinez, I., Lee, S.-H., Sheshadri, S., Xiang, Z., Merugu, S., Gu, Y., Yen, S.-C., et al. (2015) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2015.01.006 · Cited by 48 · see citing works
Optimization of selective stimulation parameters for multi-contact electrodes
Fisher, L. E., Tyler, D. J., & Triolo, R. J. (2013) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-10-25 · Cited by 45 · see citing works
Ambulatory searching task reveals importance of somatosensation for lower-limb amputees
Christie, B. P., Charkhkar, H., Shell, C. E., Burant, C. J., Tyler, D. J., & Triolo, R. J. (2020) · Scientific Reports · doi:10.1038/s41598-020-67032-3 · Cited by 37 · see citing works
Implantable Device Fabrication and Packaging
Stieglitz, T. (2023) · Handbook of Neuroengineering · doi:10.1007/978-981-16-5540-1_102 · Cited by 7 · see citing works
- Authors
- Bhadra, N., Kilgore, K. L., & Peckham, P. H.
- Affiliations
- MetroHealth Medical Center (US)
- United States Department of Veterans Affairs (US)
- Corresponding author
- Bhadra, N
- Venue
- Medical Engineering & Physics
- Publisher
- IOP Publishing
- Published
- 2001-01-01
- Volume
- 23
- Issue
- 1
- Pages
- 19-28
- ISSN
- 1350-4533 (ISSN-L)
- 1873-4030
- OpenAlex
- W2149989616
- Cited by
- 92
- References
- 35
- Citations by year
- 2026: 3 · 2025: 1 · 2024: 2 · 2023: 2 · 2022: 2 · 2021: 5 · 2020: 4 · 2019: 6 · 2018: 2 · 2017: 6 · 2016: 1 · 2015: 2 · 2014: 7 · 2013: 2 · 2012: 5
- FWCI
- 3.32
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- Medical Engineering & Physics (publishedVersion)
- PubMed (publishedVersion)
- Funders
- U.S. Department of Veterans Affairs
- Case Western Reserve University
- National Institute for Health and Care Research
- National Center for Research Resources (M01RR000080, 5M01RR 00080)
- NIH Clinical Center
- Topics
- Health Sciences › Medicine › Pathology and Forensic Medicine › Spinal Cord Injury Research
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
- Keywords
- spinal cord injury, neuromuscular electrical stimulation, implantable stimulator, stroke rehabilitation, bowel and bladder function, functional restoration, chronic stimulation
- MeSH terms
- Arm, Biomedical Engineering, Electric Stimulation Therapy, Humans, Leg, Prosthesis Design, Spinal Cord Injuries, Prostheses and Implants
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review