Observations on the Effect of Movement on Bone Ingrowth into Porous-Surfaced Implants
The DOI matches its Crossref record.
Abstract
Although porous-surfaced orthopedic implants have been designed for fixation by bone ingrowth, there is clinical evidence that this does not always occur. Initial implant movement relative to host bone can result in attachment by a nonmineralized fibrous connective tissue layer. The ranges of movement that result in either bone or fibrous connective tissue fixation are observed in dogs in two independent studies. Experimentally, bone ingrowth can occur in the presence of some movement, albeit very small (up to 28 mu), while excess movement (150 mu or more) can result in attachment by mature connective tissue ingrowth.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Murphy, C. M., Haugh, M. G., & O'Brien, F. J. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2009.09.063 · Cited by 2,056
Fabrication methods of porous metals for use in orthopaedic applications
Ryan, G., Pandit, A., & Apatsidis, D. P. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.12.002 · Cited by 1,391
Acetabular defect classification and surgical reconstruction in revision arthroplasty
Paprosky, W. G., Perona, P. G., & Lawrence, J. M. (1994) · The Journal of Arthroplasty · doi:10.1016/0883-5403(94)90135-x · Cited by 1,217
Szmukler-Moncler, S., Salama, H., Reingewirtz, Y., & Dubruille, J. H. (1998) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199822)43:2<192::aid-jbm14>3.0.co;2-k · Cited by 794
Improved bone-forming functionality on diameter-controlled TiO2 nanotube surface
Brammer, K. S., Oh, S., Cobb, C. J., Bjursten, L. M., Heyde, H. V. D., & Jin, S. (2009) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.05.008 · Cited by 593
Additive Manufacturing of Titanium Alloys by Electron Beam Melting: A Review
Zhang, L., Liu, Y., Li, S., & Hao, Y. (2018) · Advanced Engineering Materials · doi:10.1002/adem.201700842 · Cited by 486
Significantly accelerated osteoblast cell growth on aligned TiO2 nanotubes
Oh, S., Daraio, C., Chen, L., Pisanic, T. R., Fiñones, R. R., & Jin, S. (2006) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30722 · Cited by 474
Javed, F., Ahmed, H. B., Crespi, R., & Romanos, G. E. (2013) · Interventional Medicine and Applied Science · doi:10.1556/imas.5.2013.4.3 · Cited by 457
Biomechanical factors affecting the bone-dental implant interface
Brunski, J. B. (1992) · Clinical Materials · doi:10.1016/0267-6605(92)90049-y · Cited by 407
Bone ingrowth in porous titanium implants produced by 3D fiber deposition
Li, J. P., Habibovic, P., van den Doel, M., Wilson, C. E., de Wijn, J. R., van Blitterswijk, C. A., & de Groot, K. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.02.020 · Cited by 393
The Role of Implant Surface Characteristics in the Healing of Bone
Kieswetter, K., Schwartz, Z., Dean, D. D., & Boyan, B. D. (1996) · Critical Reviews in Oral Biology & Medicine · doi:10.1177/10454411960070040301 · Cited by 338
Peri-implant osteogenesis in health and osteoporosis
Marco, F., Milena, F., Gianluca, G., & Vittoria, O. (2005) · Micron · doi:10.1016/j.micron.2005.07.008 · Cited by 304
Rao, P. J., Pelletier, M. H., Walsh, W. R., & Mobbs, R. J. (2014) · Orthopaedic Surgery · doi:10.1111/os.12098 · Cited by 285
Biomechanical behaviours of the bone–implant interface: a review
Gao, X., Fraulob, M., & Haïat, G. (2019) · Journal of The Royal Society Interface · doi:10.1098/rsif.2019.0259 · Cited by 263
Biomechanics of reverse total shoulder arthroplasty
Berliner, J. L., Regalado-Magdos, A., Ma, C. B., & Feeley, B. T. (2015) · Journal of Shoulder and Elbow Surgery · doi:10.1016/j.jse.2014.08.003 · Cited by 242
“During cyclical loading, micromotion of the baseplate remains below 62 to 113 mm, which is less than the 150-mm threshold demonstrated to be necessary for bone ingrowth into total hip arthroplasty femoral components.(12,44,48,52,61,73) However, the presence of scapular notching may increase baseplate micromotion above…”
BackgroundTaylor, M., & Prendergast, P. J. (2015) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.12.019 · Cited by 199
“Bone ingrowth/ongrowth will occur if the micromotions are less than 40-50 microns and fibrous tissue formation will occur if the micromotions are in excess of 150 microns[133].”
BackgroundWan, C., & Hao, Z. (2018) · Computer Methods in Biomechanics and Biomedical Engineering · doi:10.1080/10255842.2018.1447103 · Cited by 10
“…motion in our simulations was 0.107 mm at the site TP site under the 400 ATD load, followed by 0.049 mm at the site TM and 0.043 mm at the site FD. Pilliar et al. (1986) observed that some fibrocartilagous tissues are generated on the interface for achieving attachments when the relative…”
MethodInfluential
Metadata
- Authors
- PILLIAR, R. M., LEE, J. M., & MANIATOPOULOS, C.
- Venue
- Clinical Orthopaedics and Related Research
- Published
- 1986-07
- Volume
- 208
- Issue
- 208
- Pages
- 108-113
- ISSN
- 0009-921X (ISSN-L)
- OpenAlex
- W2006822913
- Cited by
- 1,182
- References
- 0
- FWCI
- 4.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.