The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Spine Interbody Implants: Material Selection and Modification, Functionalization and Bioactivation of Surfaces to Improve Osseointegration
Open accessAbstract
The clinical outcome of lumbar spinal fusion is correlated with achievement of bony fusion. Improving interbody implant bone on‐growth and in‐growth may enhance fusion, limiting pseudoarthrosis, stress shielding, subsidence and implant failure. Polyetheretherketone (PEEK) and titanium (Ti) are commonly selected for interbody spacer construction. Although these materials have desirable biocompatibility and mechanical properties, they require further modification to support osseointegration. Reports of extensive research on this topic are available in biomaterial‐centric published reports; however, there are few clinical studies concerning surface modification of interbody spinal implants. The current article focuses on surface modifications aimed at fostering osseointegration from a clinician's point of view. Surface modification of Ti by creating rougher surfaces, modifying its surface topography (macro and nano), physical and chemical treatment and creating a porous material with high interconnectivity can improve its osseointegrative potential and bioactivity. Coating the surface with osteoconductive materials like hydroxyapatite (HA) can improve osseointegration. Because PEEK spacers are relatively inert, creating a composite by adding Ti or osteoconductive materials like HA can improve osseointegration. In addition,PEEK may be coated with Ti, effectively bio‐activating the coating.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bonding mechanisms at the interface of ceramic prosthetic materials
Hench, L. L., Splinter, R. J., Allen, W. C., & Greenlee, T. K. (1971) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820050611 · Cited by 3,251
Osteoblast adhesion on biomaterials
Anselme, K. (2000) · Biomaterials · doi:10.1016/s0142-9612(99)00242-2 · Cited by 2,500
PEEK biomaterials in trauma, orthopedic, and spinal implants
Kurtz, S. M., & Devine, J. N. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.07.013 · Cited by 2,388
Calcium Phosphate Ceramics as Hard Tissue Prosthetics
JARCHO, M. (1981) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198106000-00037 · Cited by 2,014
Understanding protein adsorption phenomena at solid surfaces
Rabe, M., Verdes, D., & Seeger, S. (2011) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2010.12.007 · Cited by 1,664
Biomedical applications of polymer-composite materials: a review
Ramakrishna, S., Mayer, J., Wintermantel, E., & Leong, K. W. (2001) · Composites Science and Technology · doi:10.1016/s0266-3538(00)00241-4 · Cited by 1,642
Navarro, M., Michiardi, A., Castaño, O., & Planell, J. A. (2008) · Journal of The Royal Society Interface · doi:10.1098/rsif.2008.0151 · Cited by 1,513
Carragee, E. J., Hurwitz, E. L., & Weiner, B. K. (2011) · The Spine Journal · doi:10.1016/j.spinee.2011.04.023 · Cited by 1,395
Iliac Crest Bone Graft Harvest Donor Site Morbidity: A Statistical Evaluation
Banwart, J. C., Asher, M. A., & Hassanein, R. S. (1995) · Spine · doi:10.1097/00007632-199505000-00012 · Cited by 1,274
Observations on the Effect of Movement on Bone Ingrowth into Porous-Surfaced Implants
PILLIAR, R. M., LEE, J. M., & MANIATOPOULOS, C. (1986) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198607000-00023 · Cited by 1,182
Cited by
Extrusion-based additive manufacturing of PEEK for biomedical applications
Vaezi, M., & Yang, S. (2015) · Virtual and Physical Prototyping · doi:10.1080/17452759.2015.1097053 · Cited by 406
Trends in lumbar spinal fusion—a literature review
Reisener, M.-J., Pumberger, M., Shue, J., Girardi, F. P., & Hughes, A. P. (2020) · Journal of Spine Surgery · doi:10.21037/jss-20-492 · Cited by 308
Seaman, S., Kerezoudis, P., Bydon, M., Torner, J. C., & Hitchon, P. W. (2017) · Journal of Clinical Neuroscience · doi:10.1016/j.jocn.2017.06.062 · Cited by 294
McGilvray, K. C., Easley, J., Seim, H. B., Regan, D., Berven, S. H., Hsu, W. K., Mroz, T. E., & Puttlitz, C. M. (2018) · The Spine Journal · doi:10.1016/j.spinee.2018.02.018 · Cited by 256
Montesissa, M., Sassoni, E., Boi, M., Borciani, G., Boanini, E., & Graziani, G. (2024) · Nanomaterials · doi:10.3390/nano14161332 · Cited by 17
Metadata
- Authors
- Rao, P. J., Pelletier, M. H., Walsh, W. R., & Mobbs, R. J.
- Venue
- Orthopaedic Surgery
- Publisher
- Wiley
- Published
- 2014-05
- Volume
- 6
- Issue
- 2
- Pages
- 81-89
- ISSN
- 1757-7853 (ISSN-L)
- 1757-7861
- OpenAlex
- W1602598524
- Cited by
- 285
- References
- 40
- FWCI
- 7.61
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Spine Interbody Implants: Material Selection and Modification, Functionalization and Bioactivation of Surfaces to Improve Osseointegration. https://app.cochat.ai/papers/10.1111/os.12098
- The paper
- Rao, P. J., Pelletier, M. H., Walsh, W. R., & Mobbs, R. J. (2014). Spine Interbody Implants: Material Selection and Modification, Functionalization and Bioactivation of Surfaces to Improve Osseointegration. Orthopaedic Surgery. https://doi.org/10.1111/os.12098
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.