The DOI matches its Crossref record.
Early Temporary Porosis of Bone Induced by Internal Fixation Implants A Reaction to Necrosis, Not to Stress Protection?
Abstract
Stabilization of the fracture using implants requires contact surfaces between implant and bone. Such contact has been observed to induce bone porosis first seen at one month after surgery. Bone loss in the vicinity of implants has hitherto been explained as being induced by mechanical unloading of the bone (stress protection). Experiments in sheep, dogs, and rabbits combining intravital staining of blood circulation and polychrome fluorescent labeling of bone remodeling leads to the conclusion that early bone porosis in the vicinity of the implants is the result of internal remodeling of cortical bone and is induced by necrosis rather than by unloading. This theory is favored by the evidence that (1) the bone porosis is of a temporary nature, an intermediate stage in internal bone remodeling; (2) the pattern of the remodeling zone is closely related to that of the disturbed circulation, and not to that of unloading; (3) plastic plates may produce more porosis than steel plates; and (4) improved blood circulation using modified plates resulted in reduced porosis. The clinical relevance of these findings is related first to the temporary weakening of the bone, and second to the possibility of sequestration. Sequestration may be the result of intensified remodeling activity in the presence of inflammation or infection.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Internal plate fixation of fractures: short history and recent developments
Uhthoff, H. K., Poitras, P., & Backman, D. S. (2006) · Journal of Orthopaedic Science · doi:10.1007/s00776-005-0984-7 · Cited by 438
Hardware Removal: Indications and Expectations
Busam, M. L., Esther, R. J., & Obremskey, W. T. (2006) · Journal of the American Academy of Orthopaedic Surgeons · doi:10.5435/00124635-200602000-00006 · Cited by 313
Machine Learning‐Driven Biomaterials Evolution
Suwardi, A., Wang, F., Xue, K., Han, M., Teo, P., Wang, P., Wang, S., Liu, Y., Ye, E., Li, Z., et al. (2022) · Advanced Materials · doi:10.1002/adma.202102703 · Cited by 299
Materials evolution of bone plates for internal fixation of bone fractures: A review
Li, J., Qin, L., Yang, K., Ma, Z., Wang, Y., Cheng, L., & Zhao, D. (2020) · Journal of Materials Science & Technology · doi:10.1016/j.jmst.2019.07.024 · Cited by 288
Glatt, V., Evans, C. H., & Tetsworth, K. (2017) · Frontiers in Physiology · doi:10.3389/fphys.2016.00678 · Cited by 194
“In fact, any appearance of callus formation was thought to indicate fracture instability (Perren et al., 1988).”
Background
Metadata
- Authors
- PERREN, S. M., CORDEY, J., RAHN, B. A., GAUTIER, E., & SCHNEIDER, E.
- Venue
- Clinical Orthopaedics and Related Research
- Published
- 1988-07
- Volume
- 232
- Issue
- 232
- Pages
- 139-151
- ISSN
- 0009-921X (ISSN-L)
- OpenAlex
- W1997877442
- Cited by
- 218
- References
- 0
- FWCI
- 2.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Early Temporary Porosis of Bone Induced by Internal Fixation Implants A Reaction to Necrosis, Not to Stress Protection? https://app.cochat.ai/papers/10.1097/00003086-198807000-00018
- The paper
- PERREN, S. M., CORDEY, J., RAHN, B. A., GAUTIER, E., & SCHNEIDER, E. (1988). Early Temporary Porosis of Bone Induced by Internal Fixation Implants A Reaction to Necrosis, Not to Stress Protection? Clinical Orthopaedics and Related Research. https://doi.org/10.1097/00003086-198807000-00018
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.