The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Internal plate fixation of fractures: short history and recent developments
Open accessAbstract
Metal plates for internal fixation of fractures have been used for more than 100 years. Although initial shortcomings such as corrosion and insufficient strength have been overcome, more recent designs have not solved all problems. Further research is needed to develop a plate that accelerates fracture healing while not interfering with bone physiology. The introduction of rigid plates had by far the greatest impact on plate fixation of fractures. However, it led to cortical porosis, delayed bridging, and refractures after plate removal. These unwarranted effects were said to be caused by bone-plate contact interfering with cortical perfusion. Consequently, further plate modifications aimed to reduce this contact area to minimize necrosis and subsequent porosis. The advocates of limited-contact plates have not published measurements of the contact area or proof of the temporary nature of the porosis. Moreover, clinical studies of newer plate types have failed to show a superior outcome. Histomor-phometric measurements of the cortex showed no difference in the extent of necrosis under plates having different contact areas. Necrosis was predominant in the periosteal cortical half, whereas porosis occurred mostly in the endosteal cortical half. No positive correlation was found between either. The scientific evidence to date strongly suggests that bone loss is caused by stress shielding and not interference with cortical perfusion secondary to bone-plate contact. Consequently, an axially compressible plate (ACP) incorporating polylactide (PLA) inserts press-fit around screw holes was designed. The bioresorbable inserts should allow for (1) increased micromotion in the axial plane to promote healing during the union phase and (2) gradual degradation over time to decrease stress shielding during the remodeling phase. Results of ongoing experimental results are encouraging. Only plates allowing dynamic compression in the axial plane can lead to a revolution in fracture fixation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Perren, S. M. (2002) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.84b8.13752 · Cited by 1,247
Clinical Application of the Tension-Stress Effect for Limb Lengthening
ILIZAROV, G. A. (1990) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199001000-00003 · Cited by 1,217
The influence of induced micromovement upon the healing of experimental tibial fractures
Goodship, A., & Kenwright, J. (1985) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.67b4.4030869 · Cited by 903
Bone loss in response to long-term immobilisation
Uhthoff, H., & Jaworski, Z. (1978) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.60b3.681422 · Cited by 388
Self-citationCurrent concepts of internal fixation of fractures
Tubbs, N. (1981) · Injury · doi:10.1016/0020-1383(81)90078-4 · Cited by 326
Bone Structure Changes in the Dog Under Rigid Internal Fixation
Uhthoff, H. K., & Dubuc, F. L. (1971) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-197111000-00026 · Cited by 281
Self-citationPERREN, S. M., CORDEY, J., RAHN, B. A., GAUTIER, E., & SCHNEIDER, E. (1988) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198807000-00018 · Cited by 218
Biological internal fixation of fractures
Gerber, C., Mast, J. W., & Ganz, R. (1990) · Archives of Orthopaedic and Trauma Surgery · doi:10.1007/bf00636165 · Cited by 176
Revolution in plate osteosynthesis: new internal fixator systems
Schütz, M., & Südkamp, N. P. (2003) · Journal of Orthopaedic Science · doi:10.1007/s007760300044 · Cited by 172
The effects of metal plates on post-traumatic remodelling and bone mass
Uhthoff, H. K., & Finnegan, M. (1983) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.65b1.6822605 · Cited by 155
Self-citation
Cited by
PEEK biomaterials in trauma, orthopedic, and spinal implants
Kurtz, S. M., & Devine, J. N. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.07.013 · Cited by 2,388
Fast escape of hydrogen from gas cavities around corroding magnesium implants
Kuhlmann, J., Bartsch, I., Willbold, E., Schuchardt, S., Holz, O., Hort, N., Höche, D., Heineman, W. R., & Witte, F. (2013) · Acta Biomaterialia · doi:10.1016/j.actbio.2012.10.008 · Cited by 310
Fused filament fabrication of peek: A review of process-structure-property relationships
Zanjanijam, A. R., Major, I., Lyons, J. G., Lafont, U., & Devine, D. M. (2020) · Polymers · doi:10.3390/polym12081665 · Cited by 240
Glatt, V., Evans, C. H., & Tetsworth, K. (2017) · Frontiers in Physiology · doi:10.3389/fphys.2016.00678 · Cited by 194
Metadata
- Authors
- Uhthoff, H. K., Poitras, P., & Backman, D. S.
- Venue
- Journal of Orthopaedic Science
- Publisher
- Elsevier BV
- Published
- 2006-03
- Volume
- 11
- Issue
- 2
- Pages
- 118-126
- ISSN
- 0949-2658 (ISSN-L)
- OpenAlex
- W2065548060
- Cited by
- 438
- References
- 18
- FWCI
- 4.43
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Internal plate fixation of fractures: short history and recent developments. https://app.cochat.ai/papers/10.1007/s00776-005-0984-7
- The paper
- Uhthoff, H. K., Poitras, P., & Backman, D. S. (2006). Internal plate fixation of fractures: short history and recent developments. Journal of Orthopaedic Science. https://doi.org/10.1007/s00776-005-0984-7
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.