Controlled Mechanical Stimulation in the Treatment of Tibial Fractures
The DOI matches its Crossref record.
Abstract
Although it is known that the mechanical environment affects the fracture healing process, the optimal conditions for the different stages of healing have not been defined. In the present studies, the influence of applying a very short period of axial micromovement with defined characteristics to healing fractures has been studied both in simulated and clinical tibial fractures. The fracture healing process is seen to be acutely sensitive to small periods of daily strain applied axially within two weeks of fracture. There are boundaries of strain magnitude and force of application of applied movement that, if exceeded, inhibit the healing process. The application of appropriate applied strain to clinical tibial fractures at a time shortly after injury, when most patients would be very inactive, appears to enhance the healing process when using external skeletal fixation.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The optimal amount of axial interfragmentary movement (IFM) has been reported to be in the range of 0.4–0.5 mm, depending on the distance of the fracture gap (21, 22).”
From Methods to accelerate fracture healing – a narrative review from a clinical perspective (2024) · cites this paper as [21]
Citations
Cites
Still being checked.
Cited by
Items 101–200 of 371
The effect of devascularisation upon early bone healing in dynamic external fixation
Wallace, A., Draper, E. R. C., Strachan, R., McCarthy, I. D., & Hughes, S. P. F. (1991) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.73b5.1894674 · Cited by 51
Goodman, S. B., Wang, J., Doshi, A., & Aspenberg, P. (1993) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820271109 · Cited by 58
Mechanically-regulated bone repair
Anani, T., & Castillo, A. B. (2021) · Bone · doi:10.1016/j.bone.2021.116223 · Cited by 49
What Are the Biomechanical Properties of the Taylor Spatial Frame™?
Henderson, D. J. H., Rushbrook, J. L., Harwood, P. J., & Stewart, T. D. (2016) · Clinical Orthopaedics and Related Research · doi:10.1007/s11999-016-5182-8 · Cited by 48
Radke, H., ARON, D. N., Applewhite, A. A., & Zhang, G. (2006) · Veterinary Surgery · doi:10.1111/j.1532-950x.2005.00106.x · Cited by 47
Biomechanical concepts of fracture healing in weight-bearing long bones.
Ulstrup, A. K. (2008) · PubMed · Cited by 64
Cross, A. R., Lewis, D. D., Murphy, S. T., Rigaud, S., Madison, J. B., Kehoe, M. M., & Rapoff, A. J. (2001) · American Journal of Veterinary Research · doi:10.2460/ajvr.2001.62.1025 · Cited by 47
Perren, S. M., FERNANDEZ, A., & Regazzoni, P. (2015) · Acta chirurgiae orthopaedicae et traumatologiae Cechoslovaca · doi:10.55095/achot2015/039 · Cited by 45
Reverse Dynamization Accelerates Bone-Healing in a Large-Animal Osteotomy Model
Glatt, V., Samchukov, M. L., Cherkashin, A. M., & Iobst, C. (2020) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.20.00380 · Cited by 47
In vivo effect of shock-waves on the healing of fractured bone
Augat, P., Claes, L., & Suger, G. (1995) · Clinical Biomechanics · doi:10.1016/0268-0033(95)00009-a · Cited by 45
Glatt, V., Bartnikowski, N., Quirk, N., Schuetz, M., & Evans, C. H. (2016) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.15.01027 · Cited by 44
Mehta, M., Checa, S., Lienau, J., Hutmacher, D. W., & Duda, G. N. (2012) · European Cells and Materials · doi:10.22203/ecm.v024a26 · Cited by 43
Can Tibial Shaft Fractures Bear Weight After Intramedullary Nailing? A Randomized Controlled Trial
Gross, S. C., Galos, D. K., Taormina, D. P., Crespo, A. M., Egol, K. A., & Tejwani, N. C. (2016) · Journal of Orthopaedic Trauma · doi:10.1097/bot.0000000000000598 · Cited by 43
The influence of gap size on the development of fracture union with a micro external fixator
Meeson, R., Moazen, M., Sanghani‐Kerai, A., Osagie-Clouard, L., Coathup, M. J., & Blunn, G. W. (2019) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2019.07.015 · Cited by 43
The Muscle Bed-A Crucial Factor for Fracture Healing: A Physiological Concept
Stein, H., Perren, S. M., Cordey, J., KENWRIGHT, J., Mosheiff, R., & Francis, M. J. O. (2002) · Orthopedics · doi:10.3928/0147-7447-20021201-16 · Cited by 43
Self-citationGoodship, A. E. (1992) · Annals of the Rheumatic Diseases · doi:10.1136/ard.51.1.4 · Cited by 42
Self-citationStrategies of enhancing bone regenerate formation in distraction osteogenesis
Alzahrani, M. M., Anam, E. A., Al-Qahtani, S. M., Makhdom, A. M., & Hamdy, R. C. (2017) · Connective Tissue Research · doi:10.1080/03008207.2017.1288725 · Cited by 45
Biomechanical and clinical implications of distraction osteogenesis in craniofacial surgery
Meyer, U., Kleinheinz, J., & Joos, U. (2004) · Journal of Cranio-Maxillofacial Surgery · doi:10.1016/j.jcms.2003.12.003 · Cited by 42
Circular External Fixation Frames with Divergent Half Pins: A Pilot Biomechanical Study
Lenarz, C. J., Bledsoe, G., & Watson, T. J. (2008) · Clinical Orthopaedics and Related Research · doi:10.1007/s11999-008-0492-0 · Cited by 45
Neuromuscular electrical stimulation enhances fracture healing: results of an animal model
Park, S., & Silva, M. (2004) · Journal of Orthopaedic Research® · doi:10.1016/j.orthres.2003.08.007 · Cited by 41
Mechanobiologie der Frakturheilung Teil 1
Claes, L. (2016) · Der Unfallchirurg · doi:10.1007/s00113-016-0280-3 · Cited by 41
A novel model to study metaphyseal bone healing under defined biomechanical conditions
Claes, L., Veeser, A., Göckelmann, M., Simon, U., & Ignatius, A. A. (2008) · Archives of Orthopaedic and Trauma Surgery · doi:10.1007/s00402-008-0692-9 · Cited by 40
Richter, H., Plecko, M., Andermatt, D., Frigg, R., Kronen, P., Klein, K., Nuss, K. M. R., Ferguson, S. J., Stöckle, U., & von Rechenberg, B. (2015) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.m.00529 · Cited by 39
Bliemel, C., Buecking, B., Mueller, T., Wack, C., Koutras, C., Beck, T., Ruchholtz, S., & Zettl, R. (2014) · Archives of Orthopaedic and Trauma Surgery · doi:10.1007/s00402-014-2111-8 · Cited by 39
Mitogens are increased in the systemic circulation during bone callus healing
Kaspar, D., Neidlinger‐Wilke, C., Holbein, O., Claes, L., & Ignatius, A. A. (2003) · Journal of Orthopaedic Research® · doi:10.1016/s0736-0266(02)00134-1 · Cited by 39
Torres, L. A. G., Gómez‐Benito, M. J., Doblaré, M., & García‐Aznar, J. M. (2010) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2010.01.010 · Cited by 39
Callus Response to Micromovement After Elongation in the Rabbit
Kassis, B., Glorion, C., Tabib, W., Blanchard, O., & Pouliquen, J. (1996) · Journal of Pediatric Orthopaedics · doi:10.1097/01241398-199607000-00011 · Cited by 39
Shahar, R. (2000) · Veterinary Surgery · doi:10.1111/j.1532-950x.2000.00059.x · Cited by 38
Traini, T., Degidi, M., Strocchi, R., Caputi, S., & Piattelli, A. (2005) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.30245 · Cited by 42
Concepts and clinical aspects of active implants for the treatment of bone fractures
Ganse, B., Orth, M., Roland, M., Diebels, S., Motzki, P., Seelecke, S., Kirsch, S.-M., Welsch, F., Andres, A., Wickert, K., et al. (2022) · Acta Biomaterialia · doi:10.1016/j.actbio.2022.05.001 · Cited by 37
Connolly, C., Li, G., Bunn, J. R., Mushipe, M. T., Dickson, G. R., & Marsh, D. (2003) · Journal of Orthopaedic Research® · doi:10.1016/s0736-0266(03)00041-x · Cited by 42
Eisenhauer, P., Chernets, N., Song, Y., Dobrynin, D., Pleshko, N. L., Steinbeck, M. J., & Freeman, T. A. (2016) · Journal of Tissue Engineering and Regenerative Medicine · doi:10.1002/term.2224 · Cited by 36
The influence of external fixators on fracture motion during simulated walking
Gardner, T., Evans, M., & KENWRIGHT, J. (1996) · Medical Engineering & Physics · doi:10.1016/1350-4533(95)00056-9 · Cited by 36
Self-citationFailure Processes in Biometallic Materials
Sumita, M., Hanawa, T., Ohnishi, I., & Yoneyama, T. (2003) · Elsevier eBooks · doi:10.1016/b0-08-043749-4/09143-6 · Cited by 35
Principles of bone formation driven by biophysical forces in craniofacial surgery
Meyer, U., Kruse‐Lösler, B., & Wiesmann, H. (2005) · British Journal of Oral and Maxillofacial Surgery · doi:10.1016/j.bjoms.2005.06.026 · Cited by 35
Knee Loading Accelerates Bone Healing in Mice
Zhang, P., Sun, Q. W., Turner, C. H., & Yokota, H. (2007) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.070803 · Cited by 35
McCartney, W. T., MacDonald, B., & Hashmi, M. S. J. (2005) · Journal of Materials Processing Technology · doi:10.1016/j.jmatprotec.2005.04.104 · Cited by 34
Haptic Biofeedback for Improving Compliance With Lower-Extremity Partial Weight Bearing
Fu, M. C., DeLuke, L., Buerba, R. A., Fan, R. E., Zheng, Y., Leslie, M. P., Baumgaertner, M. R., & Grauer, J. N. (2014) · Orthopedics · doi:10.3928/01477447-20141023-56 · Cited by 36
Methods to accelerate fracture healing – a narrative review from a clinical perspective
Ganse, B. (2024) · Frontiers in Immunology · doi:10.3389/fimmu.2024.1384783 · Cited by 33
“The optimal amount of axial interfragmentary movement (IFM) has been reported to be in the range of 0.4 – 0.5 mm, depending on the distance of the fracture gap (21, 22).”
BackgroundInfluentialGhimire, S., Miramini, S., Richardson, M., Mendis, P. A., & Zhang, L. (2019) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2019.03.004 · Cited by 33
Biomechanical Concepts Applicable to Minimally Invasive Fracture Repair in Small Animals
Chao, P., Lewis, D. D., Kowaleski, M. P., & Pozzi, A. (2012) · Veterinary Clinics of North America Small Animal Practice · doi:10.1016/j.cvsm.2012.07.007 · Cited by 33
Vetter, A., Liu, Y., Witt, F., Manjubala, I., Sander, O., Epari, D. R., Fratzl, P., Duda, G. N., & Weinkamer, R. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2010.09.009 · Cited by 42
Burkhart, K. J., Nowak, T. E., Gradl, G., Klitscher, D., Mehling, I. M., Mehler, D., Mueller, L. P., & Rommens, P. M. (2010) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2010.06.004 · Cited by 32
Reina-Romo, E., Gómez‐Benito, M. J., Domínguez, J., Niemeyer, F., Wehner, T., Simon, U., & Claes, L. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2010.11.033 · Cited by 31
Gemmill, T. J., Cave, T. A., Clements, D. N., Clarke, S. P., Bennett, D., & Carmichael, S. (2004) · Journal of Small Animal Practice · doi:10.1111/j.1748-5827.2004.tb00208.x · Cited by 31
HENTE, R., Cordey, J., Rahn, B. A., Maghsudi, M., Gumppenberg, S. V., & Perren, S. M. (1999) · Injury · doi:10.1016/s0020-1383(99)00126-6 · Cited by 31
Comparison of cyclic compression, cyclic distraction and rigid fixation: Bone healing in rabbits
Matsushita, T., & Kurokawa, T. (1998) · Acta Orthopaedica Scandinavica · doi:10.3109/17453679809002365 · Cited by 31
Stress protection due to external fixation
O'Doherty, D. M., Butler, S., & Goodship, A. E. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(94)00104-c · Cited by 35
Self-citationMcKellop, H. A., Hoffmann, R. F. G., Sarmiento, A., & Ebramzadeh, E. (1993) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-199307000-00008 · Cited by 34
The combined effects of dynamization time and degree on bone healing
Fu, R., Feng, Y., Liu, Y., Willie, B. M., & Yang, H. (2021) · Journal of Orthopaedic Research® · doi:10.1002/jor.25060 · Cited by 31
Henderson, D. J. H., Rushbrook, J. L., Stewart, T. D., & Harwood, P. J. (2015) · Clinical Orthopaedics and Related Research · doi:10.1007/s11999-015-4652-8 · Cited by 30
Rendenbach, C., Steffen, C., Sellenschloh, K., Heyland, M., Morlock, M. M., Toivonen, J., Moritz, N., Smeets, R., Heiland, M., VALLITTU, P. K., et al. (2018) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2018.12.014 · Cited by 31
Horn, J., Gueorguiev, B. G., Brianza, S., Steen, H., & Schwieger, K. (2011) · Journal of Orthopaedic Trauma · doi:10.1097/bot.0b013e3181ffdf9a · Cited by 29
Mechanobiology of Bone Tissue and Bone Cells
Liedert, A., Kaspar, D., Augat, P., Ignatius, A. A., & Claes, L. (2005) · Cited by 47
Yamaji, T., Ando, K., Nakamura, T., Washimi, O., Terada, N., & Yamada, H. (2002) · Journal of Orthopaedic Science · doi:10.1007/s007760200082 · Cited by 29
Winkelstabile Verriegelung von Marknägeln mit dem Angular Stable Locking System® (ASLS)
Höntzsch, D., Blauth, M., & Attal, R. (2011) · Operative Orthopädie und Traumatologie · doi:10.1007/s00064-011-0048-4 · Cited by 28
Cold atmospheric plasma is a viable solution for treating orthopedic infection: a review
Nguyen, L., Lu, P. C., Boehm, D., Bourke, P., Gilmore, B., Hickok, N. J., & Freeman, T. A. (2018) · Biological Chemistry · doi:10.1515/hsz-2018-0235 · Cited by 29
Höntzsch, D., Schaser, K., Hofmann, G. O., Pohlemann, T., Hem, E. S., Rothenbach, E., Krettek, C., & Attal, R. (2014) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.m.01355 · Cited by 30
Challis, M., Jull, G. A., Stanton, W., & Welsh, M. K. (2007) · Australian Journal of Physiotherapy · doi:10.1016/s0004-9514(07)70005-3 · Cited by 32
Relative stiffness, transverse displacement and dynamization in comparable external fixators
Gardner, T., & Evans, M. (1992) · Clinical Biomechanics · doi:10.1016/s0268-0033(92)90006-p · Cited by 27
Gabarre, S., Albareda, J., Gracia, L., Puértolas, S., Ibarz, E., & Herrera, A. (2017) · Injury · doi:10.1016/s0020-1383(17)30793-3 · Cited by 26
Intact fibula improves fracture healing in a rat tibia osteotomy model
Shefelbine, S. J., Augat, P., Claes, L., & Beck, A. (2004) · Journal of Orthopaedic Research® · doi:10.1016/j.orthres.2004.08.007 · Cited by 26
Joint Loading Modality: Its Application to Bone Formation and Fracture Healing
Zhang, P., Malacinski, G. M., & Yokota, H. (2007) · British Journal of Sports Medicine · doi:10.1136/bjsm.2007.042556 · Cited by 25
Rechter, G. R., Anthony, R. T., Rennard, J., Kellam, J. F., & Warner, S. J. (2024) · Injury · doi:10.1016/j.injury.2024.111917 · Cited by 27
The absence of immediate stimulation delays bone healing
Barcik, J. P., Ernst, M., Buchholz, T., Constant, C., Mys, K., Epari, D. R., Zeiter, S., & Windolf, M. (2023) · Bone · doi:10.1016/j.bone.2023.116834 · Cited by 25
Geßmann, J., Çıtak, M., Jettkant, B., Schildhauer, T. A., & Seybold, D. (2011) · Journal of Orthopaedic Surgery and Research · doi:10.1186/1749-799x-6-61 · Cited by 30
Wang, G., Pan, T., Peng, X., & Wang, J. (2008) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2007.10.017 · Cited by 24
The effect of clamping a tensioned wire: Implications for the Ilizarov external fixation system
Watson, M. A., Mathias, K. J., Maffulli, N., & Hukins, D. W. L. (2003) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1243/09544110360579295 · Cited by 26
Treatment of compound fractures
Seligson, D., & Henry, S. L. (1991) · The American Journal of Surgery · doi:10.1016/0002-9610(91)91258-k · Cited by 24
Rethinking the 10% strain rule in fracture healing: A distal femur fracture case series
Inacio, J. V., Schwarzenberg, P., Kantzos, A., Malige, A., Nwachuku, C. O., & Dailey, H. L. (2022) · Journal of Orthopaedic Research® · doi:10.1002/jor.25446 · Cited by 26
The influence of compression on the healing of experimental tibial fractures
Sigurdsen, U., Reikerås, O., & Utvåg, S. E. (2010) · Injury · doi:10.1016/j.injury.2010.08.018 · Cited by 23
Kogure, A., Mori, Y., Tanaka, H., Kamimura, M., Masahashi, N., Hanada, S., & Itoi, E. (2018) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.34163 · Cited by 23
Tsuzuki, T., Okabe, K., Kajiya, H., & Habu, T. (2000) · The Japanese Journal of Physiology · doi:10.2170/jjphysiol.50.67 · Cited by 22
Subtrochanteric Fixation Stability Depends on Discrete Fracture Surface Points
Bredbenner, T. L., Snyder, S. A., Mazloomi, F. R., Le, T., & Wilber, R. G. (2005) · Clinical Orthopaedics and Related Research · doi:10.1097/01.blo.0000150375.13488.a9 · Cited by 24
Gardner, T., Evans, M., & Kyberd, P. (1996) · Journal of Biomechanical Engineering · doi:10.1115/1.2796048 · Cited by 22
Smith, A. N., Ulsh, J. B., Gupta, R., Tang, M. M., Peredo, A. P., Teinturier, T. D., Mauck, R. L., Gullbrand, S. E., & Hast, M. W. (2023) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2024.106457 · Cited by 21
Computerised and technical navigation in total knee-arthroplasty
Böhling, U., Schamberger, H., Grittner, U., & Scholz, J. (2005) · Journal of Orthopaedics and Traumatology · doi:10.1007/s10195-005-0084-7 · Cited by 21
Hay, S. M., Rickman, M. S., & Saleh, M. (1997) · Injury · doi:10.1016/s0020-1383(97)00025-9 · Cited by 20
The Ilizarov external fixator: What remains of the wire pretension after dynamic loading?
Renard, A. J. S., Schutte, B. G., Verdonschot, N. J. J., & van Kampen, A. (2005) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2005.07.007 · Cited by 20
Biomechanical study of internal fixation methods for femoral neck fractures based on Pauwels angle
Wang, F., Liu, Y., Huo, Y., Wang, Z., Zhang, J., Xu, M., Ma, K., Wang, L., Lü, Y., Cheng, L., et al. (2023) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2023.1143575 · Cited by 19
Conformational Instability of the Taylor Spatial Frame: A Case Report and Biomechanical Study
Henderson, E. R., Feldman, D. S., Lusk, C. P., van Bosse, H. J. P., Sala, D. A., & Kummer, F. J. (2008) · Journal of Pediatric Orthopaedics · doi:10.1097/bpo.0b013e318173ecb1 · Cited by 19
Gardner, T., Evans, M., Simpson, H., & Turner-Smith, A. R. (1994) · Clinical Biomechanics · doi:10.1016/0268-0033(94)90058-2 · Cited by 19
Ignatius, A. A., Blessing, H., Liedert, A., Kaspar, D., Kreja, L., Friemert, B., & Claes, L. (2004) · Der Orthopäde · doi:10.1007/s00132-004-0735-z · Cited by 19
A Biomechanical Strength Comparison of External Fixators
Sladicka, S. J., Duffin, S. R., & Erpelding, J. M. (1998) · doi:10.1097/00005373-199806000-00006 · Cited by 19
4. Biomechanical evaluation of the Pinless external fixator
Stene, G. M., Frigg, R., Schlegel, U., & Swiontkowski, M. F. (1992) · Injury · doi:10.1016/0020-1383(92)90004-c · Cited by 19
Dayton, P., Santrock, R. D., Kauwe, M., Gansen, G., Harper, S., Cifaldi, A., Egdorf, R., & Eisenschink, J. (2019) · The Journal of Foot & Ankle Surgery · doi:10.1053/j.jfas.2018.09.001 · Cited by 18
Implantable biosensors for musculoskeletal health
Nash, K. E., Ong, K. G., & Guldberg, R. E. (2022) · Connective Tissue Research · doi:10.1080/03008207.2022.2041002 · Cited by 19
Computational models of bone fracture healing and applications: a review
Wang, M., Jiang, G., Yang, H., & Jin, X. (2024) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmt-2023-0088 · Cited by 21
Sun, Z., & Herring, S. W. (2009) · Archives of Oral Biology · doi:10.1016/j.archoralbio.2008.12.002 · Cited by 18
A NEW ERA IN ORTHOPEDIC TRAUMA CARE
Browner, B. D., Alberta, F. G., & Mastella, D. J. (1999) · Surgical Clinics of North America · doi:10.1016/s0039-6109(05)70086-4 · Cited by 19
Wettere, A. J. V., Redig, P. T., Wallace, L. J., Bourgeault, C. A., & Bechtold, J. E. (2009) · Journal of Avian Medicine and Surgery · doi:10.1647/1082-6742-23.4.277 · Cited by 18
Eddy, A. L., Galuppo, L. D., Stover, S. M., Taylor, K. T., & Jensen, D. G. (2004) · Veterinary Surgery · doi:10.1111/j.1532-950x.2004.04037.x · Cited by 18
Tanveer, M., Klein, K., von Rechenberg, B., Darwiche, S., & Dailey, H. L. (2025) · Bone and Joint Research · doi:10.1302/2046-3758.141.bjr-2024-0191.r2 · Cited by 20
Effect of GaAlAs Laser Irradiation on the Epiphyseal Cartilage of Rats
Cressoni, M. D. C., Giusti, H. H. K. D., Pião, A. C. S., Carvalho, R. L. D. P., Anaruma, C. A., & Casarotto, R. A. (2010) · Photomedicine and Laser Surgery · doi:10.1089/pho.2009.2572 · Cited by 17
Reumann, M. K., Nair, T., Strachna, O., Boskey, A. L., & Mayer‐Kuckuk, P. (2010) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00839.2010 · Cited by 17
Dailey, H. L., Daly, C. J., Galbraith, J. G., Cronin, M. S., & Harty, J. A. (2013) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2013.04.006 · Cited by 19
TIBIOTARSAL FRACTURE REPAIR IN A BALD EAGLE (HALIAEETUS LEUCOCEPHALUS) USING AN INTERLOCKING NAIL
Hollamby, S., Déjardin, L. M., Sikarskie, J. G., & Haeger, J. (2004) · Journal of Zoo and Wildlife Medicine · doi:10.1638/02-086 · Cited by 17
Xie, Q., Li, X., & Wang, P. (2023) · Journal of orthopaedic surgery · doi:10.1177/10225536231175235 · Cited by 16
Williams, K. E., Harrer, J. A., LaBelle, S. A., Leguineche, K., Kaiser, J. M., Karipott, S. S., Lin, A., Vongphachanh, A., Fulton, T. M., Rosenthal, J. W., et al. (2024) · npj Regenerative Medicine · doi:10.1038/s41536-024-00377-9 · Cited by 19
Zelken, J. A., Hayes, A. G., Parks, B. G., Muhit, A. A., & Means, K. R. (2015) · The Journal Of Hand Surgery · doi:10.1016/j.jhsa.2015.02.012 · Cited by 16
Metadata
- Authors
- KENWRIGHT, J., & GOODSHIP, A. E.
- Affiliations
- Nuffield Orthopaedic Centre (GB)
- ORCID
- GOODSHIP, ALLEN E.
- Venue
- Clinical Orthopaedics and Related Research
- Published
- 1989-04
- Volume
- 241
- Issue
- 241
- Pages
- 36-47
- ISSN
- 0009-921X (ISSN-L)
- OpenAlex
- W2018626421
- Cited by
- 373
- References
- 0
- Citations by year
- 2026: 4 · 2025: 6 · 2024: 11 · 2023: 14 · 2022: 7 · 2021: 10 · 2020: 7 · 2019: 10 · 2018: 9 · 2017: 5 · 2016: 9 · 2015: 8 · 2014: 7 · 2013: 6 · 2012: 14
- FWCI
- 5.18
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Clinical Orthopaedics and Related Research (publishedVersion)
- PubMed (publishedVersion)
- UCL Discovery (University College London) (submittedVersion)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone fractures and treatments
- Health Sciences › Medicine › Surgery › Hip and Femur Fractures
- Health Sciences › Medicine › Surgery › Spinal Fractures and Fixation Techniques
- Keywords
- tibial fractures, fracture healing, mechanical stimulation, applied strain, external fixation, mechanical environment
- MeSH terms
- Animals, Biomechanical Phenomena, Bony Callus, Elasticity, Fracture Fixation, Humans, Minerals, Orthopedic Fixation Devices, Physical Stimulation, Sheep, Stress, Mechanical, Tibial Fractures, Wound Healing
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).