Controlled Mechanical Stimulation in the Treatment of Tibial Fractures
The DOI matches its Crossref record.
Abstract
Although it is known that the mechanical environment affects the fracture healing process, the optimal conditions for the different stages of healing have not been defined. In the present studies, the influence of applying a very short period of axial micromovement with defined characteristics to healing fractures has been studied both in simulated and clinical tibial fractures. The fracture healing process is seen to be acutely sensitive to small periods of daily strain applied axially within two weeks of fracture. There are boundaries of strain magnitude and force of application of applied movement that, if exceeded, inhibit the healing process. The application of appropriate applied strain to clinical tibial fractures at a time shortly after injury, when most patients would be very inactive, appears to enhance the healing process when using external skeletal fixation.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The optimal amount of axial interfragmentary movement (IFM) has been reported to be in the range of 0.4–0.5 mm, depending on the distance of the fracture gap (21, 22).”
From Methods to accelerate fracture healing – a narrative review from a clinical perspective (2024) · cites this paper as [21]
Citations
Cites
Still being checked.
Cited by
Items 201–300 of 371
A novel intramedullary nail for micromotion stimulation of tibial fractures
Dailey, H. L., Daly, C. J., Galbraith, J. G., Cronin, M. S., & Harty, J. A. (2011) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2011.08.009 · Cited by 17
A review of bone growth stimulation for fracture treatment
Behrens, S. B., Deren, M. E., & Monchik, K. O. (2012) · Current Orthopaedic Practice · doi:10.1097/bco.0b013e3182793faa · Cited by 16
Gardner, T., Mishra, S. K., & Marks, L. (2004) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2004.03.009 · Cited by 16
Metcalfe, A. J., Saleh, M., & Yang, L. (2005) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.87b6.15672 · Cited by 16
Singh, G. R., Aithal, H. P., SAXENA, R. K., Kinjavdekar, P., AMARPAL, M., Hoque, M., Maiti, S. K., PAWDE, A. M., & JOSHI, H. C. (2007) · Veterinary Surgery · doi:10.1111/j.1532-950x.2007.00239.x · Cited by 22
Sigurdsen, U., Reikerås, O., & Utvåg, S. E. (2010) · Journal of Investigative Surgery · doi:10.3109/08941930903564118 · Cited by 15
In vitro comparison of stiffness of plate fixation of radii from large- and small-breed dogs
Gauthier, C. M., Conrad, B. P., Lewis, D. D., & Pozzi, A. (2011) · American Journal of Veterinary Research · doi:10.2460/ajvr.72.8.1112 · Cited by 15
Challis, M., Gaston, P., Wilson, K., Jull, G. A., & Crawford, R. (2006) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.88b3.16856 · Cited by 16
Novel uses of carbon composites for the fabrication of external fixators
Migliaresi, C., Nicoli, F., Rossi, S., & Pegoretti, A. (2003) · Composites Science and Technology · doi:10.1016/j.compscitech.2003.09.003 · Cited by 15
Goodman, S. B., Song, Y., Doshi, A., & Aspenberg, P. (1994) · Biomaterials · doi:10.1016/0142-9612(94)90112-0 · Cited by 15
Wang, S., Wu, C., Li, W. T., Shen, H., Lin, L., & Pan, R. (2019) · International Journal of Surgery · doi:10.1016/j.ijsu.2019.03.019 · Cited by 14
Mohandes, Y., Tahani, M., Rouhi, G., & Tahami, M. (2021) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/0954411920985757 · Cited by 14
Effect of Cyclic Pneumatic Soft Tissue Compression on Simulated Distal Radius Fractures
Challis, M., Welsh, M. K., Jull, G. A., & Crawford, R. (2005) · Clinical Orthopaedics and Related Research · doi:10.1097/01.blo.0000149994.58542.c9 · Cited by 14
Masticatory mechanics of a mandibular distraction osteogenesis site: Interfragmentary micromovement
Sun, Z., Rafferty, K. L., Egbert, M. A., & Herring, S. W. (2007) · Bone · doi:10.1016/j.bone.2007.04.183 · Cited by 14
Su, H., Zhong, S., Ma, T., Wu, W., Lu, Y., & Wang, D. (2023) · BMC Musculoskeletal Disorders · doi:10.1186/s12891-023-06150-1 · Cited by 13
Reduced Gap Strains Induce Changes in Bone Regeneration During Distraction
Richards, M., Waanders, N. A., Weiss, J. A., Bhatia, V., Senunas, L. E., Schaffler, M. B., Goldstein, S. A., & Goulet, J. A. (1999) · Journal of Biomechanical Engineering · doi:10.1115/1.2798331 · Cited by 14
Gorman, S. C., Kraus, K. H., Keating, J. H., Tidwell, A. S., Rand, W. M., Parkington, J. D., & Boudrieau, R. J. (2005) · Veterinary and Comparative Orthopaedics and Traumatology · doi:10.1055/s-0038-1632964 · Cited by 15
In Vitro Cyclic Biomechanical Properties of an Interlocking Equine Tibial Nail
McDuffee, L. A., Stover, S. M., & Taylor, K. T. (2000) · Veterinary Surgery · doi:10.1111/j.1532-950x.2000.00163.x · Cited by 12
Toe-Touch Weight Bearing: Myth or Reality?
Rubin, G., Monder, O., Zohar, R., Oster, A., Konra, O., & Rozen, N. (2010) · Orthopedics · doi:10.3928/01477447-20100826-02 · Cited by 12
External fixation of the foot and ankle
Hamilton, G. A., & Ford, L. A. (2003) · Clinics in Podiatric Medicine and Surgery · doi:10.1016/s0891-8422(02)00053-8 · Cited by 12
The static and dynamic behaviour of tibial fractures due to unlocking external fixators
Gardner, T., Hardy, J. R. W., Evans, M., Richardson, J., & KENWRIGHT, J. (1996) · Clinical Biomechanics · doi:10.1016/s0268-0033(96)00038-1 · Cited by 19
Self-citationGardner, T., Evans, M., & Simpson, H. (1998) · Medical Engineering & Physics · doi:10.1016/s1350-4533(98)00035-6 · Cited by 12
Li, H., Li, D., Qiao, F., Tang, L., & Han, Q. (2021) · BioMed Research International · doi:10.1155/2021/8539416 · Cited by 11
Roland, M., Diebels, S., Wickert, K., Pohlemann, T., & Ganse, B. (2024) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2024.1420047 · Cited by 11
(i) The principles of foot and ankle arthrodesis
Parker, L. D., & Singh, D. S. (2009) · Orthopaedics and Trauma · doi:10.1016/j.mporth.2009.08.006 · Cited by 11
Barquet, A., Massaferro, J., Dubra, A., Milans, C., & Castiglioni, O. (1992) · Injury · doi:10.1016/0020-1383(92)90064-y · Cited by 11
Advancements in micromotion-based fixation systems for fracture healing
Lv, J., Qi, W., & Leung, F. K. L. (2025) · Journal of orthopaedic surgery · doi:10.1177/10225536251352559 · Cited by 11
Biomechanical comparison of two locking plate systems for the distal tibia
Högel, F., Hoffmann, S., Weninger, P., Bühren, V., & Augat, P. (2011) · European Journal of Trauma and Emergency Surgery · doi:10.1007/s00068-011-0123-4 · Cited by 10
Nikonovas, A., & Harrison, A. J. (2005) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1243/095441105x9228 · Cited by 10
Wettere, A. J. V., Wallace, L. J., Redig, P. T., Bourgeault, C. A., & Bechtold, J. E. (2009) · Journal of Avian Medicine and Surgery · doi:10.1647/1082-6742-23.4.263 · Cited by 10
England, T., Khan, H., Moniz, S., Mitchell, D., & Kuster, M. S. (2023) · Journal of Clinical Medicine · doi:10.3390/jcm12247554 · Cited by 9
Computational characterization of fracture healing under reduced gravity loading conditions
Gadomski, B. C., Lerner, Z. F., Browning, R. C., Easley, J. T., Palmer, R. H., & Puttlitz, C. M. (2015) · Journal of Orthopaedic Research® · doi:10.1002/jor.23143 · Cited by 9
Bousdras, V., Sindet‐Pedersen, S., Cunningham, J. L., Blunn, G. W., Petrie, A., Naert, I. E., Jaecques, S., & Goodship, A. E. (2007) · Clinical Implant Dentistry and Related Research · doi:10.1111/j.1708-8208.2007.00038.x · Cited by 9
Self-citationRole of the fibula in lower leg fractures: An in vivo investigation in rats
Horn, J., Steen, H., & Reikerås, O. (2008) · Journal of Orthopaedic Research® · doi:10.1002/jor.20605 · Cited by 9
Partale, K., Klein, P., Schell, H., Schmidmaier, G., Wildemann, B., Bail, H. J., Schiller, R. A., Bragulla, H. H., & Duda, G. N. (2005) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.30254 · Cited by 9
Great debates in trauma biomechanics
Glatt, V., O’Toole, R. V., Mehta, S. D., Kandemir, U., Ricci, W. M., Nauth, A., Schemitsch, E. H., & Hast, M. W. (2023) · OTA International The Open Access Journal of Orthopaedic Trauma · doi:10.1097/oi9.0000000000000249 · Cited by 8
Sağlam, N., Söylemez, M. S., Türkmen, İ., & Akpınar, F. (2020) · European Journal of Trauma and Emergency Surgery · doi:10.1007/s00068-020-01303-6 · Cited by 8
Reich, K. M., Tangl, S., Heimel, P., Lettner, S., Ignatius, A. A., Claes, L., Pfeil, J., Janousek, A., & Redl, H. R. (2019) · BioMed Research International · doi:10.1155/2019/4250940 · Cited by 10
Sliding performance of unilateral external fixators for tibia
Matsushita, T., Nakamura, K., Ohnishi, I., & Kurokawa, T. (1998) · Medical Engineering & Physics · doi:10.1016/s1350-4533(97)00050-7 · Cited by 8
Mabuchi, K., Fujie, H., Yamatoku, Y., Yamamoto, M., & Sasada, T. (1992) · Springer eBooks · doi:10.1007/978-4-431-68216-5_10 · Cited by 8
Yan, Z.-K., Zou, C., Kenmegne, G. R., Pan, X., Ghimire, N., Silva, K. M. N., & Fang, Y. (2024) · Journal of Orthopaedic Surgery and Research · doi:10.1186/s13018-024-04686-z · Cited by 7
Design and preliminary testing of an active intramedullary nail.
Letechipia, J., Alessi, A., Rodríguez, G., & Asbún, J. (2014) · PubMed · Cited by 9
Yao, J.-F., Shen, J., Da-kun, L. I., Lin, D., Li, L., Li, Q., Qi, P., Lian, K., & Ding, Z. (2012) · International Journal of Medical Sciences · doi:10.7150/ijms.4242 · Cited by 7
Panagakos, P., Patel, K., & Gonzalez, C. N. (2012) · Clinics in Podiatric Medicine and Surgery · doi:10.1016/j.cpm.2011.09.005 · Cited by 7
Case-based prediction in experimental medical studies
Seitz, A., Uhrmacher, A. M., & Damm, D. E. (1999) · Artificial Intelligence in Medicine · doi:10.1016/s0933-3657(98)00057-8 · Cited by 7
Bousdras, V., Walboomers, F., Jansen, J. A., Cunningham, J. L., Blunn, G. W., Petrie, A., Jaecques, S., Naert, I. E., Sindet‐Pedersen, S., & Goodship, A. E. (2007) · Clinical Implant Dentistry and Related Research · doi:10.1111/j.1708-8208.2007.00039.x · Cited by 7
Self-citationExternal fixators for elective rearfoot and ankle arthrodesis
Kalish, S. R., Fleming, J. J., & Weinstein, R. B. (2003) · Clinics in Podiatric Medicine and Surgery · doi:10.1016/s0891-8422(02)00054-x · Cited by 9
Hyomex: a miniature universal testing machine forin vivobiomechanical studies
Hult, E., Ekstrom, L., Holm, S., & Hansson, T. (1994) · Journal of Medical Engineering & Technology · doi:10.3109/03091909409030247 · Cited by 7
Implant Surface Design for Development and Maintenance of Osseointegration
Pilliar, R. M. (2003) · CRC Press eBooks · doi:10.1201/9780203491430.ch3 · Cited by 7
A novel external fixation for treating tibial fractures: a finite element and biomechanical study
Liu, S., Liang, X., Liu, S., Guo, Z., Wei, X., & Liang, Y. (2025) · Journal of Orthopaedic Surgery and Research · doi:10.1186/s13018-025-05681-8 · Cited by 6
Benjamin, B., Ryan, P., Chechelnitskaya, Y., Bayam, L., Syed, T. A., & Drampalos, E. (2021) · World Journal of Orthopedics · doi:10.5312/wjo.v12.i12.1036 · Cited by 6
Finlay, J. B., Hurtig, M., Hardie, W. R., Liggins, A. B., & Batte, S. W. P. (1995) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1243/pime_proc_1995_209_315_02 · Cited by 6
Control of the micromovements of a composite-material nail design: A finite element analysis
Ben-Or, M., Shavit, R., Ben‐Tov, T., Salai, M., & Steinberg, E. L. (2015) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2015.09.011 · Cited by 6
Nonlinear Increasing Axial Gap Stiffness in Type II External Skeletal Fixation: A Mechanical Study
Kowaleski, M. P., Marston, M. T., & Kraus, K. H. (2003) · Veterinary Surgery · doi:10.1053/jvet.2003.50006 · Cited by 7
Augmentation of Bone Healing by Specific Frequency and Amplitude Compressive Strains
Shadmehr, A., Esteki, A., Oliaie, G. R., Torkaman, G., & Sabbaghian, A. (2009) · Orthopedics · doi:10.3928/01477447-20090301-26 · Cited by 6
Mechanical testing and modelling of a bone-implant construct
Grant, C. A. (2012) · Cited by 7
Klemeit, A., Weber, A. K., Bourauel, C. P., Welle, K., Burger, C., Schildberg, F. A., & Deborre, C. (2023) · Bioengineering · doi:10.3390/bioengineering10080982 · Cited by 5
Ün, K., Akçalı, İ. D., & Gülşen, M. (2006) · Journal of Medical Devices · doi:10.1115/1.2735972 · Cited by 5
Reconstructive surgery of the human tibia by use of external ring fixator and the Ilizarov method
Kristiansen, L. P. (2009) · Acta Orthopaedica · doi:10.1080/17453690610046576 · Cited by 5
Mechanical Performance of an Axially Mobile Plate for Fracture Fixation
Sun, J., Abel, E. W., & ROWLEY, D. I. (1998) · doi:10.1097/00005373-199802000-00024 · Cited by 5
Biomechanical comparison of five external wrist fixators.
Chang, D. S., Kummer, F. J., Egol, K., Tejwani, N. C., Wolinsky, P. R., & Koval, K. J. (2002) · PubMed · Cited by 5
Cells Involved in Mechanotransduction Including Mesenchymal Stem Cells
Zuckerman, P. C., Liu, C., & Castillo, A. B. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-801238-3.11209-7 · Cited by 5
Subject-specific multivariate modeling for regenerative rehabilitation of bone healing
Williams, K. E., Muhib, F., Dinh, E., Leguineche, K., Hajarizadeh, A., Rosenthal, J. W., Guyer, T., Seah, T., Willett, N. J., Weiss, J. A., et al. (2025) · APL Bioengineering · doi:10.1063/5.0273944 · Cited by 5
Lotzien, S., Rosteius, T., Jettkant, B., Cibura, C., Rausch, V., Schildhauer, T. A., & Geßmann, J. (2022) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2022.105820 · Cited by 4
Effect of a Supplemental Plate on the Stiffness of a Type I External Fixator
Norris, J. L., Kraus, K. H., & O'Leary, J. P. (2002) · Veterinary Surgery · doi:10.1053/jvet.2002.31042 · Cited by 4
The emergence of mechanoregulated endochondral ossification in evolution
Khayyeri, H., & Prendergast, P. J. (2012) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2012.11.030 · Cited by 4
Mathematical Modelling of Stress and Strain in Bone Fracture Repair Tissue
Gardner, T., Stoll, T., Marks, L., & Tate, M. L. K. (2020) · CRC Press eBooks · doi:10.1201/9781003078289-34 · Cited by 4
Mechanical considerations in fracture fixation
Krishnakanth, P. (2012) · Faculty of Built Environment and Engineering; Institute of Health and Biomedical Innovation · Cited by 6
Couverture des pertes de substance post-traumatiques du membre inférieur
Rausky, J., Mazouz-Dorval, S., Noel, W., Binder, J.-P., & Revol, M. P. (2015) · Cited by 3
Väisänen, A., HOIKKALA, N.-P. J., Härkönen, V., Moritz, N., & VALLITTU, P. K. (2024) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2024.106604 · Cited by 3
Hybrid additive manufacturing for Zn-Mg casting for biomedical application
Shahed, K. S., Fainor, M., Gullbrand, S. E., Hast, M. W., & Manogharan, G. P. (2024) · In vitro models · doi:10.1007/s44164-024-00077-0 · Cited by 3
The effects of bovine trabecular bone matrix particulates on cortical bone repair
Mushipe, M. T., Revell, P. A., & Shelton, J. C. (2002) · Journal of Materials Science Materials in Medicine · doi:10.1023/a:1013607207410 · Cited by 3
Walczyk, D., & Bartlet, J. P. (2006) · Journal of Medical Devices · doi:10.1115/1.2355690 · Cited by 3
In vitro biomechanical testing of a micro external skeletal fixator
Bali, M., Doherr, M. G., Spreng, D., Rytz, U., Ferguson, S. J., & Deiss, R. (2013) · Veterinary and Comparative Orthopaedics and Traumatology · doi:10.3415/vcot-12-10-0126 · Cited by 3
Généralités sur les fractures de l'enfant
Pouliquen, J., Glorion, C., Langlais, J., & Ceolin, J. L. (2006) · EMC - Appareil locomoteur · doi:10.1016/s0246-0521(02)00109-2 · Cited by 3
Lin, D., Hong, J., Lian, K., Zhai, W., & Ding, Z. (2010) · Journal of Pediatric Orthopaedics · doi:10.1097/bpo.0b013e3181fbebc7 · Cited by 3
The Influence of Induced Micromovent Upon the Healing of Experimental Tibial Fractures
Kumar, G., & Narayan, B. (2013) · Springer eBooks · doi:10.1007/978-1-4471-5451-8_131 · Cited by 3
Erdem, S., Gür, M., & Kaman, M. O. (2018) · Bio-Medical Materials and Engineering · doi:10.3233/bme-181012 · Cited by 4
Mechanical Influences on Skeletal Regeneration
Carter, D. R. P., Loboa, E. G., & Beaupré, G. S. (2000) · Springer eBooks · doi:10.1007/978-4-431-66967-8_17 · Cited by 3
Neue Trends bei der Versorgung von Schaftfrakturen
Haas, N. P., & Krettek, C. (1991) · Langenbecks Archiv für Chirurgie. Supplement · doi:10.1007/978-3-642-95662-1_207 · Cited by 3
Compression-aided stability of orthopaedic devices
Pitz, M. K. (2011) · SMARTech Repository (Georgia Institute of Technology) · Cited by 3
Periprosthetic Bone Mineral Density and Other Orthopedic Applications
Trevisan, C. L., & Ortolani, S. (1998) · Springer eBooks · doi:10.1007/978-3-642-80440-3_28 · Cited by 3
Knochenheilung unter dynamischer Frakturstabilisierung
Claes, L. (1991) · Springer eBooks · doi:10.1007/978-3-642-76328-1_11 · Cited by 3
Functionally graded 3D printed plates for rib fracture fixation
Gupta, R., Judkins, L., Friday, C. S., Ulsh, J. B., Kovach, S. J., Mehta, S. D., Tomonto, C., Manogharan, G. P., & Hast, M. W. (2023) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2023.106151 · Cited by 2
Choi, D., Ishii, T., Ishikawa, M., Ootake, T., Kamei, H., Kohei, N., & Sueishi, K. (2023) · Biomedicines · doi:10.3390/biomedicines11020444 · Cited by 3
Bone Healing in the Presence of Orthopaedic Implants
Gupta, S. (2023) · Springer eBooks · doi:10.1007/978-981-19-7540-0_50 · Cited by 2
Stabile Ringfixateurmontage beim Segmenttransport: Mechanische Einflussfaktoren und Komplikationen
Geßmann, J., Dudda, M., Schildhauer, T. A., & Seybold, D. (2012) · Trauma und Berufskrankheit · doi:10.1007/s10039-012-1888-3 · Cited by 2
Is the stability of a tibial fracture influenced by the type of unilateral external fixator?
Gardner, T., Evans, M., Hardy, J., & KENWRIGHT, J. (1998) · Clinical Biomechanics · doi:10.1016/s0268-0033(98)00044-8 · Cited by 2
Self-citationDamaraju, S., & Duncan, N. A. (2013) · Computational methods in applied sciences · doi:10.1007/978-94-007-7073-7_1 · Cited by 3
Intermittent vibrations accelerate fracture healing in sheep
Mu, D., Yu, J., Lin, J., Li, C., Hao, B., Gu, F., Liu, C., Tan, L., Zhu, D., & Zhang, X. (2019) · Acta Cirúrgica Brasileira · doi:10.1590/s0102-865020190070000002 · Cited by 2
Regenerative Rehabilitation Strategies for Complex Bone Injuries
Nash, K. E., Ong, K. G., Gebreyesus, E. A., LaBelle, S. A., Weiss, J. A., Harrer, J. A., Willett, N. J., Leucht, P., & Guldberg, R. E. (2022) · Physiology in health and disease · doi:10.1007/978-3-030-95884-8_8 · Cited by 2
Bone Healing in the Presence of Orthopaedic Implants
Gupta, S. (2023) · Springer eBooks · doi:10.1007/978-981-15-6278-5_50-2 · Cited by 2
McCartney, W. T. (2002) · Dublin City University Open Access Institutional Repository (Dublin City University) · Cited by 2
The measurement of bone strain in vivo
Goodship, A. E. (1992) · Springer eBooks · doi:10.1007/978-94-011-2330-3_5 · Cited by 2
Self-citationExtended use of the k wire and the orthopaedic screw:
Baker, A. S. (2000) · Injury · doi:10.1016/s0020-1383(00)00055-3 · Cited by 2
A data-logging system to monitor bone fracture movement continuously
Moorcroft, C. I., Ogrodnik, P. J., Thomas, P. B., & Verborg, S. (1997) · Medical Engineering & Physics · doi:10.1016/s1350-4533(96)00068-9 · Cited by 2
Effects of Fibrous Hydroxyapatite on the Process of Bone Formation
Sakurai, M. (1993) · The Showa University Journal of Medical Sciences · doi:10.15369/sujms1989.5.209 · Cited by 2
Mechanical testing of the wire clamping characteristics of the Fixclip™ internal fixation system
Vadivelu, R., Baker, A. S., & Chetwynd, D. G. (2002) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1243/09544110260216621 · Cited by 2
Modern concepts in plate osteosynthesis
Stoffel, K. (2007) · UWA Profiles and Research Repository (UWA) · Cited by 2
Li, J., Zhao, X., Tao, C., & Ji, R. (2018) · Vibroengineering PROCEDIA · doi:10.21595/vp.2018.19812 · Cited by 1
Metadata
- Authors
- KENWRIGHT, J., & GOODSHIP, A. E.
- Affiliations
- Nuffield Orthopaedic Centre (GB)
- ORCID
- GOODSHIP, ALLEN E.
- Venue
- Clinical Orthopaedics and Related Research
- Published
- 1989-04
- Volume
- 241
- Issue
- 241
- Pages
- 36-47
- ISSN
- 0009-921X (ISSN-L)
- OpenAlex
- W2018626421
- Cited by
- 373
- References
- 0
- Citations by year
- 2026: 4 · 2025: 6 · 2024: 11 · 2023: 14 · 2022: 7 · 2021: 10 · 2020: 7 · 2019: 10 · 2018: 9 · 2017: 5 · 2016: 9 · 2015: 8 · 2014: 7 · 2013: 6 · 2012: 14
- FWCI
- 5.18
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Clinical Orthopaedics and Related Research (publishedVersion)
- PubMed (publishedVersion)
- UCL Discovery (University College London) (submittedVersion)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone fractures and treatments
- Health Sciences › Medicine › Surgery › Hip and Femur Fractures
- Health Sciences › Medicine › Surgery › Spinal Fractures and Fixation Techniques
- Keywords
- tibial fractures, fracture healing, mechanical stimulation, applied strain, external fixation, mechanical environment
- MeSH terms
- Animals, Biomechanical Phenomena, Bony Callus, Elasticity, Fracture Fixation, Humans, Minerals, Orthopedic Fixation Devices, Physical Stimulation, Sheep, Stress, Mechanical, Tibial Fractures, Wound Healing
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.