The DOI matches its Crossref record.
Current Concepts of Fracture Healing
Abstract
The current concepts of fracture healing are mainly based on two variables: blood supply and stability. The effect of electricity on delayed union has not been explained. Possible individual differences in the primary osteogenetic activity and the effect of soft-tissue injuries are seldom considered. In recent years, interesting data have revealed how biomechanical forces and electric currents can be translated to biochemical mediators such as prostaglandins (PGE2), morphogens, and growth factors. It is likely that the fracture ends emit osteogenic signal substances (such as bone morphogenetic protein) to the exudate in addition to those mediators (interleukin-1, growth factors) which are released from the blood clot as in wound healing. Movement of the fragments increases the fracture exudate with its migrating cells and sprouting vessels, resulting in exuberant callus. Cartilage is formed in the well-vascularized granulation tissue due to its ability to repel vessels. Rigid fixation minimizes granulation tissue and external callus. Rigid plates may also retard effusion of morphogens and growth factors from bone ends. Reaming of the intramedullary canal and nailing may cause additional bone damage, which may increase the osteogenetic activity. Weight bearing stimulates growth factors and PGE2. The molecular activity of the fracture exudate is the most decisive factor for bone healing. This activity can be impeded by diastasis, infections, and soft-tissue crushing injuries that cause extensive activation of macrophages and activate mediators, disturbing the osteogenesis.(ABSTRACT TRUNCATED AT 250 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
New Developments of Ti-Based Alloys for Biomedical Applications
Li, Y., Yang, C., Zhao, H., Qu, S., Li, X., & Li, Y. (2014) · Materials · doi:10.3390/ma7031709 · Cited by 1,048
Claes, L. E., & Heigele, C. A. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00153-5 · Cited by 802
Effects of Mechanical Factors on the Fracture Healing Process
Claes, L. E., Heigele, C. A., Neidlinger-Wilke, C., Kaspar, D., Seidl, W., Margevicius, K. J., & Augat, P. (1998) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199810001-00015 · Cited by 705
Farouk, O., Krettek, C., Miclau, T., Schandelmaier, P., Guy, P., & Tscherne, H. (1999) · Journal of Orthopaedic Trauma · doi:10.1097/00005131-199908000-00002 · Cited by 326
Risk factors contributing to fracture non-unions
Calori, G. M., Albisetti, W., Agus, A., Iori, S., & Tagliabue, L. (2007) · Injury · doi:10.1016/s0020-1383(07)80004-0 · Cited by 290
Metadata
- Authors
- Hulth, A.
- Venue
- Clinical Orthopaedics and Related Research
- Published
- 1989-12
- Volume
- 249
- Issue
- 249
- Pages
- 265-284
- ISSN
- 0009-921X (ISSN-L)
- OpenAlex
- W2041922317
- Cited by
- 226
- References
- 0
- FWCI
- 4.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Current Concepts of Fracture Healing. https://app.cochat.ai/papers/10.1097/00003086-198912000-00028
- The paper
- Hulth, A. (1989). Current Concepts of Fracture Healing. Clinical Orthopaedics and Related Research. https://doi.org/10.1097/00003086-198912000-00028
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.