The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Minimally Invasive Plate Osteosynthesis: Does Percutaneous Plating Disrupt Femoral Blood Supply Less Than the Traditional Technique?
Abstract
OBJECTIVES/HYPOTHESIS: Proximal and distal femur fractures have traditionally been treated with open reduction and internal fixation through a standard lateral approach. New, "minimally invasive" internal fixation techniques, however, have been developed in an effort to devascularize the bone less than the traditional method. The purpose of this study was to determine whether a minimally invasive percutaneous plating technique better preserves bone vascularity relative to the traditional method by comparing the effect of the two approaches on the blood supply of the distal femur using silicone arterial dye injection in a cadaveric model. STUDY DESIGN/METHODS: Ten fresh human cadavers underwent lateral conventional plate osteosynthesis (CPO) through a standard lateral approach on one side and minimally invasive plate osteosynthesis (MIPO) through two three-centimeter incisions on the contralateral side. After injection of silicone dye, a dissection was performed bilaterally to identify the femoral perforating and nutrient arteries. RESULTS: All MIPO specimens showed intact perforating and nutrient arteries, whereas the CPO specimens had a variable incidence of vessel disruption. The MIPO group demonstrated better periosteal perfusion in each of the cadavers and improved medullary perfusion in 70 percent of the MIPO specimens compared with the CPO specimens. CONCLUSION: A percutaneous minimally invasive plating technique disrupts the femoral blood supply less than the traditional open method. Such minimally invasive methods may be more advantageous biologically than the traditional method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The biology of fracture healing in long bones
McKibbin, B. (1978) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.60b2.350882 · Cited by 1,180
Tibial Blood Supply in Relation to Fracture Healing
Rhinelander, F. W. (1974) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-197411000-00005 · Cited by 494
The Normal Microcirculation of Diaphyseal Cortex and Its Response to Fracture
RHINELANDER, F. W. (1968) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-196850040-00016 · Cited by 344
Krettek, C., Schandelmaier, P., Nliclau, T., & Tscherne, H. (1997) · Injury · doi:10.1016/s0020-1383(97)90112-1 · Cited by 322
Self-citationCurrent Concepts of Fracture Healing
Hulth, A. (1989) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198912000-00028 · Cited by 226
Biological internal fixation of fractures
Gerber, C., Mast, J. W., & Ganz, R. (1990) · Archives of Orthopaedic and Trauma Surgery · doi:10.1007/bf00636165 · Cited by 176
Effect of Growth Factors on Bone Cell Replication and Differentiation
CANALIS, E. (1985) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198503000-00035 · Cited by 169
Cited by
Glatt, V., Evans, C. H., & Tetsworth, K. (2017) · Frontiers in Physiology · doi:10.3389/fphys.2016.00678 · Cited by 194
Metadata
- Authors
- Farouk, O., Krettek, C., Miclau, T., Schandelmaier, P., Guy, P., & Tscherne, H.
- Venue
- Journal of Orthopaedic Trauma
- Published
- 1999-08
- Volume
- 13
- Issue
- 6
- Pages
- 401-406
- ISSN
- 0890-5339 (ISSN-L)
- OpenAlex
- W2069635391
- Cited by
- 326
- References
- 7
- FWCI
- 2.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Minimally Invasive Plate Osteosynthesis: Does Percutaneous Plating Disrupt Femoral Blood Supply Less Than the Traditional Technique? https://app.cochat.ai/papers/10.1097/00005131-199908000-00002
- The paper
- Farouk, O., Krettek, C., Miclau, T., Schandelmaier, P., Guy, P., & Tscherne, H. (1999). Minimally Invasive Plate Osteosynthesis: Does Percutaneous Plating Disrupt Femoral Blood Supply Less Than the Traditional Technique? Journal of Orthopaedic Trauma. https://doi.org/10.1097/00005131-199908000-00002
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.