Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 326

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Minimally Invasive Plate Osteosynthesis: Does Percutaneous Plating Disrupt Femoral Blood Supply Less Than the Traditional Technique?

Farouk, Osama, Krettek, Christian, Miclau, Theodore, Schandelmaier, Peter, Guy, Pierre, Tscherne, Harald·1999·Journal of Orthopaedic Trauma

Abstract

OBJECTIVES/HYPOTHESIS: Proximal and distal femur fractures have traditionally been treated with open reduction and internal fixation through a standard lateral approach. New, "minimally invasive" internal fixation techniques, however, have been developed in an effort to devascularize the bone less than the traditional method. The purpose of this study was to determine whether a minimally invasive percutaneous plating technique better preserves bone vascularity relative to the traditional method by comparing the effect of the two approaches on the blood supply of the distal femur using silicone arterial dye injection in a cadaveric model. STUDY DESIGN/METHODS: Ten fresh human cadavers underwent lateral conventional plate osteosynthesis (CPO) through a standard lateral approach on one side and minimally invasive plate osteosynthesis (MIPO) through two three-centimeter incisions on the contralateral side. After injection of silicone dye, a dissection was performed bilaterally to identify the femoral perforating and nutrient arteries. RESULTS: All MIPO specimens showed intact perforating and nutrient arteries, whereas the CPO specimens had a variable incidence of vessel disruption. The MIPO group demonstrated better periosteal perfusion in each of the cadavers and improved medullary perfusion in 70 percent of the MIPO specimens compared with the CPO specimens. CONCLUSION: A percutaneous minimally invasive plating technique disrupts the femoral blood supply less than the traditional open method. Such minimally invasive methods may be more advantageous biologically than the traditional method.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00005131-199908000-00002

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

Metadata

Authors
Farouk, O., Krettek, C., Miclau, T., Schandelmaier, P., Guy, P., & Tscherne, H.
Venue
Journal of Orthopaedic Trauma
Published
1999-08
Volume
13
Issue
6
Pages
401-406
ISSN
0890-5339 (ISSN-L)
OpenAlex
W2069635391
Cited by
326
References
7
FWCI
2.81
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Minimally Invasive Plate Osteosynthesis: Does Percutaneous Plating Disrupt Femoral Blood Supply Less Than the Traditional Technique? https://app.cochat.ai/papers/10.1097/00005131-199908000-00002
The paper
Farouk, O., Krettek, C., Miclau, T., Schandelmaier, P., Guy, P., & Tscherne, H. (1999). Minimally Invasive Plate Osteosynthesis: Does Percutaneous Plating Disrupt Femoral Blood Supply Less Than the Traditional Technique? Journal of Orthopaedic Trauma. https://doi.org/10.1097/00005131-199908000-00002

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.