Material Properties and Structure-Function Relationships in the Menisci
The DOI matches its Crossref record.
Abstract
The menisci serve several important biomechanical functions in the knee. They distribute stresses over a broad area of articular cartilage, absorb shocks during dynamic loading, and probably assist in joint lubrication. These functions enhance the ability of articular cartilage to provide a smooth, near-frictionless articulation and to distribute loads evenly to the underlying bone of the femur and tibia. In addition, the menisci provide stability to the injured knee when the cruciate ligaments or other primary stabilizers are deficient. The ability to perform these mechanical functions is based on the intrinsic material properties of the menisci as well as their gross anatomic structure and attachments. The material properties of the menisci are determined by their biochemical composition and, perhaps more important, by the organization and interactions of the major tissue constituents: water, proteoglycan, and collagen. Interactions among the important constituents of the fibrocartilage matrix cause meniscal tissue to behave as a fiber-reinforced, porous, permeable composite material similar to articular cartilage, in which frictional drag caused by fluid flow governs its response to dynamic loading. The menisci are one-half as stiff in compression and dissipate more energy under dynamic loading than articular cartilage. Energy dissipation, or shock absorption, by the menisci is the result of high frictional drag caused by low permeability of the matrix, which is about one-sixth as permeable as articular cartilage. The dynamic shear modulus of meniscal tissue is only one-fourth to one-sixth as great as that of articular cartilage. The coarse, circumferential Type I collagen fiber bundles of the meniscus give the tissue great tensile stiffness (range, 100-300 megapascals) and strength. The highly oriented collagen ultrastructure of the menisci makes the tissue anisotropic in tension, compression, and shear and appears to dominate its behavior under all loading conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Makris, E. A., Hadidi, P., & Athanasiou, K. A. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.06.037 · Cited by 1,116
The Basic Science of Human Knee Menisci: Structure, Composition, and Function
Fox, A. J. S., Bedi, A., & Rodeo, S. A. (2012) · Sports Health: A Multidisciplinary Approach · doi:10.1177/1941738111429419 · Cited by 582
Meniscal Root Tears: Significance, Diagnosis, and Treatment
Bhatia, S., LaPrade, C. M., Ellman, M. B., & LaPrade, R. F. (2014) · The American Journal of Sports Medicine · doi:10.1177/0363546514524162 · Cited by 544
Peña, E., Calvo, B., Martínez, M. A., & Doblaré, M. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.04.030 · Cited by 506
Ferguson, S. J., Bryant, J. T., Ganz, R., & Ito, K. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(00)00042-7 · Cited by 455
Alford, J. W., & Cole, B. J. (2005) · The American Journal of Sports Medicine · doi:10.1177/0363546504273510 · Cited by 435
Collagenous fibril texture of the human knee joint menisci
Petersen, W., & Tillmann, B. (1998) · Anatomy and Embryology · doi:10.1007/s004290050141 · Cited by 427
Tensile and viscoelastic properties of human patellar tendon
Johnson, G. A., Tramaglini, D. M., Levine, R. E., Ohno, K., Choi, N., & L‐Y. Woo, S. (1994) · Journal of Orthopaedic Research · doi:10.1002/jor.1100120607 · Cited by 417
Li, W.-J., Mauck, R. L., Cooper, J. A., Yuan, X., & Tuan, R. S. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2006.09.004 · Cited by 400
The acetabular labrum seal: a poroelastic finite element model
Ferguson, S. J., Bryant, J. T., Ganz, R., & Ito, K. (2000) · Clinical Biomechanics · doi:10.1016/s0268-0033(99)00099-6 · Cited by 398
Meniscus pathology, osteoarthritis and the treatment controversy
Englund, M., Roemer, F. W., Hayashi, D., Crema, M. D., & Guermazi, A. (2012) · Nature Reviews Rheumatology · doi:10.1038/nrrheum.2012.69 · Cited by 385
The effect of nanofiber alignment on the maturation of engineered meniscus constructs
Baker, B. M., & Mauck, R. L. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.01.004 · Cited by 379
A two year in vivo study of polyvinyl alcohol-hydrogel (PVA-H) artificial meniscus
Kobayashi, M., Chang, Y.-S., & Oka, M. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.08.028 · Cited by 347
Peña, E., Calvo, B., Martínez, M. A., Palanca, D., & Doblaré, M. (2005) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2005.01.009 · Cited by 285
Tissue engineering of the meniscus
Buma, P., Ramrattan, N. N., van Tienen, T. G., & Veth, R. P. H. (2004) · Biomaterials · doi:10.1016/s0142-9612(03)00499-x · Cited by 253
Toward Tissue Engineering of the Knee Meniscus
Sweigart, M. A., & Athanasiou, K. A. (2001) · Tissue Engineering · doi:10.1089/107632701300062697 · Cited by 215
“57,61 It has been shown that shear properties are anisotropic, with the stiffness being the lowest in the planes that run parallel to the major collagen orientation.”
InfluentialDavidson, L. A., Koehl, M. A. R., Keller, R., & Oster, G. F. (1995) · Development · doi:10.1242/dev.121.7.2005 · Cited by 212
An injectable extracellular matrix derived hydrogel for meniscus repair and regeneration
Wu, J., Ding, Q., Dutta, A., Wang, Y., Huang, Y.-H., Weng, H., Tang, L., & Hong, Y. (2015) · Acta Biomaterialia · doi:10.1016/j.actbio.2015.01.027 · Cited by 194
“It is notable that the mechanical properties of the hydrogels are much lower than those of the native meniscus (100–400 kPa in modulus [56,57] and 100–300 MPa in tensile strength [58]).”
Meniscal Transplantation in Symptomatic Patients Less Than Fifty Years Old
Noyes, F. R., Barber-Westin, S. D., & Rankin, M. (2005) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.e.00347 · Cited by 187
Stärke, C., Kopf, S., Gröbel, K.-H., & Becker, R. (2010) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1016/j.arthro.2009.08.013 · Cited by 164
Antigen removal for the production of biomechanically functional, xenogeneic tissue grafts
Cissell, D. D., Hu, J. C., Griffiths, L. G., & Athanasiou, K. A. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2013.10.041 · Cited by 52
“Large proteoglycans serve a similar role in fibrocartilage, helping to resist compressive stress (Fithian et al., 1990).”
The role of bone marrow derived mesenchymal stem cells in sports injuries
Vris, A., Aresti, N., Khan, W. S., & Malik, A. A. (2016) · Stem Cells in Clinical Applications · doi:10.1007/978-3-319-40144-7_14 · Cited by 28
Metadata
- Authors
- FITHIAN, D. C., KELLY, M. A., & MOW, V. C.
- Venue
- Clinical Orthopaedics and Related Research
- Published
- 1990-03
- Volume
- 252
- Issue
- 252
- Pages
- 19-31
- ISSN
- 0009-921X (ISSN-L)
- OpenAlex
- W2082510662
- Cited by
- 777
- References
- 0
- FWCI
- 3.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.