Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 347

The DOI matches its Crossref record.

Arthroscopic Meniscal Repair Using an Exogenous Fibrin Clot

HENNING, CHARLES E., LYNCH, MARY A., YEAROUT, KIM M., VEQUIST, STEVEN W., STALLBAUMER, ROBERT J., DECKER, KRISTA A.·1990·Clinical Orthopaedics and Related Research

Abstract

In this series of 153 meniscus tears, 8% were isolated whereas 92% were in conjunction with anterior cruciate ligament (ACL) tears. Exogenous fibrin clot was injected with a blunt needle in the seam of the tear. One to 2 ml of clot was sufficient to fill an average defect. When gaps could not be closed, such as with a radial split or flap in the posterior one-third of the meniscus, a fascia sheath was used to cover these defects and the exogenous clot was injected under the cover of the sheath. ACL-deficient knees were stabilized with an intraarticular reconstruction. Overall results were 64% healed, 24% incompletely healed, and 12% failed (less than 50% of vertical height of tear healed). In ACL-associated knees, the failure rate was 1.5% for tears in which surgery occurred up to two months after the time of injury. The failure rate for tears surgically treated two months to several years after injury was 20%. Complex tears had an even higher failure rate of 22%. It is these tears that will be treated with the fascia sheath. The isolated tear failure rate was 41% without the exogenous fibrin clot versus 8% with the exogenous clot. Complications included retear and popliteal neurovascular injury. Repair of almost all menisci in young active athletes is possible using the transarticular arthroscopic technique with a posterior incision. Repairs of tears of less than two months' duration from the time of injury to surgery result in significantly higher healing rates than those of more chronic tears. Isolated repairs heal significantly better with exogenous fibrin clot injection.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00003086-199003000-00009

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 347

Metadata

Authors
HENNING, C. E., LYNCH, M. A., YEAROUT, K. M., VEQUIST, S. W., STALLBAUMER, R. J., & DECKER, K. A.
Venue
Clinical Orthopaedics and Related Research
Published
1990-03
Volume
252
Issue
252
Pages
64-72
ISSN
0009-921X (ISSN-L)
OpenAlex
W1987010201
Cited by
347
References
0
FWCI
10.33
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Arthroscopic Meniscal Repair Using an Exogenous Fibrin Clot. https://app.cochat.ai/papers/10.1097/00003086-199003000-00009
The paper
HENNING, C. E., LYNCH, M. A., YEAROUT, K. M., VEQUIST, S. W., STALLBAUMER, R. J., & DECKER, K. A. (1990). Arthroscopic Meniscal Repair Using an Exogenous Fibrin Clot. Clinical Orthopaedics and Related Research. https://doi.org/10.1097/00003086-199003000-00009

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.