The DOI matches its Crossref record.
Arthroscopic Meniscal Repair Using an Exogenous Fibrin Clot
Abstract
In this series of 153 meniscus tears, 8% were isolated whereas 92% were in conjunction with anterior cruciate ligament (ACL) tears. Exogenous fibrin clot was injected with a blunt needle in the seam of the tear. One to 2 ml of clot was sufficient to fill an average defect. When gaps could not be closed, such as with a radial split or flap in the posterior one-third of the meniscus, a fascia sheath was used to cover these defects and the exogenous clot was injected under the cover of the sheath. ACL-deficient knees were stabilized with an intraarticular reconstruction. Overall results were 64% healed, 24% incompletely healed, and 12% failed (less than 50% of vertical height of tear healed). In ACL-associated knees, the failure rate was 1.5% for tears in which surgery occurred up to two months after the time of injury. The failure rate for tears surgically treated two months to several years after injury was 20%. Complex tears had an even higher failure rate of 22%. It is these tears that will be treated with the fascia sheath. The isolated tear failure rate was 41% without the exogenous fibrin clot versus 8% with the exogenous clot. Complications included retear and popliteal neurovascular injury. Repair of almost all menisci in young active athletes is possible using the transarticular arthroscopic technique with a posterior incision. Repairs of tears of less than two months' duration from the time of injury to surgery result in significantly higher healing rates than those of more chronic tears. Isolated repairs heal significantly better with exogenous fibrin clot injection.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Hunziker, E. B. (2002) · Osteoarthritis and Cartilage · doi:10.1053/joca.2002.0801 · Cited by 1,975
Makris, E. A., Hadidi, P., & Athanasiou, K. A. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.06.037 · Cited by 1,116
Fibrin: A versatile scaffold for tissue engineering applications
Ahmed, T. A. E., Dare, E. V., & Hincke, M. (2008) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2007.0435 · Cited by 994
Surgical and tissue engineering strategies for articular cartilage and meniscus repair
Kwon, H., Brown, W. E., Lee, C. A., Wang, D., Paschos, N., Hu, J. C., & Athanasiou, K. A. (2019) · Nature Reviews Rheumatology · doi:10.1038/s41584-019-0255-1 · Cited by 652
MESSNER, K., & GAO, J. (1998) · Journal of Anatomy · doi:10.1046/j.1469-7580.1998.19320161.x · Cited by 431
Metadata
- Authors
- HENNING, C. E., LYNCH, M. A., YEAROUT, K. M., VEQUIST, S. W., STALLBAUMER, R. J., & DECKER, K. A.
- Venue
- Clinical Orthopaedics and Related Research
- Published
- 1990-03
- Volume
- 252
- Issue
- 252
- Pages
- 64-72
- ISSN
- 0009-921X (ISSN-L)
- OpenAlex
- W1987010201
- Cited by
- 347
- References
- 0
- FWCI
- 10.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Arthroscopic Meniscal Repair Using an Exogenous Fibrin Clot. https://app.cochat.ai/papers/10.1097/00003086-199003000-00009
- The paper
- HENNING, C. E., LYNCH, M. A., YEAROUT, K. M., VEQUIST, S. W., STALLBAUMER, R. J., & DECKER, K. A. (1990). Arthroscopic Meniscal Repair Using an Exogenous Fibrin Clot. Clinical Orthopaedics and Related Research. https://doi.org/10.1097/00003086-199003000-00009
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.