In Vivo Kinematic Analysis of a Mobile Bearing Total Knee Prosthesis
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Ten normal subjects and 10 patients with a posterior cruciate retaining mobile bearing total knee replacement performed successive deep knee bends under fluoroscopy to determine tibiofemoral contact positions. At full extension the average initial contact position for the normal and mobile total knee replacement was 6.2 mm (range, 4.8 to 12 mm) anterior, and -4.4 mm (range, 3.9 to 11 mm) posterior to the sagittal tibial midplane, respectively. At 60 degrees flexion, the normal knee rolled back to -5.8 mm (range, -2.5 to -13.2 mm), whereas the mobile bearing total knee replacement rolled back to -9.2 mm (range, -4 to -17 mm). From 60 degrees to 90 degrees, normal knees rolled back to -7.8 mm (range, -5.8 to -13.8 mm), but the mobile bearing total knee replacement slid anteriorly to -5 mm (range, 2 to -12 mm). All mobile bearing total knee replacements had some form of roll back, but some slid anterior more than others. Five of 10 mobile bearing total knee replacements had some movement of the bearings while the others remained fixed. Patellar kinematics was similar to normal but reflected tibiofemoral abnormalities.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The mechanics of the knee and prosthesis design
Goodfellow, J., & O'Connor, J. (1978) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.60b3.581081 · Cited by 446
Load Bearing Characteristics of the Patello-Femoral Joint
Matthews, L. S., Sonstegard, D. A., & Henke, J. A. (1977) · Acta Orthopaedica Scandinavica · doi:10.3109/17453677708989740 · Cited by 202
Knee biomechanics and total knee replacement
Andriacchi, T. P., Stanwyck, T. S., & Galante, J. O. (1986) · The Journal of Arthroplasty · doi:10.1016/s0883-5403(86)80033-x · Cited by 197
Interaction between intrinsic knee mechanics and the knee extensor mechanism
Draganich, L. F., Andriacchi, T. P., & Andersson, G. B. J. (1987) · Journal of Orthopaedic Research · doi:10.1002/jor.1100050409 · Cited by 182
Cited by
In Vivo Fluoroscopic Analysis of the Normal Human Knee
Komistek, R. D., Dennis, D. A., & Mahfouz, M. (2003) · Clinical Orthopaedics & Related Research · doi:10.1097/01.blo.0000062384.79828.3b · Cited by 436
Self-citationIn vivo determination of normal and anterior cruciate ligament-deficient knee kinematics
Dennis, D. A., Mahfouz, M. R., Komistek, R. D., & Hoff, W. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.02.042 · Cited by 302
Self-citationA model-based method for the reconstruction of total knee replacement kinematics
Zuffi, S., Leardini, A., Catani, F., Fantozzi, S., & Cappello, A. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.811310 · Cited by 185
“Because in videofluoroscopic examination of TKR patients during activity some occlusion between prosthesis components frequently occurs, a model-based pose estimation method for the kinematics analysis of TKR, which should overcome the limitation of the complete segmentation of components, typical of every previous te…”
BackgroundMethodThe cruciate ligaments in total knee arthroplasty
Stiehl, J. B., Komistek, R. D., Cloutier, J.-M., & Dennis, D. A. (2000) · The Journal of Arthroplasty · doi:10.1054/arth.2000.4638 · Cited by 182
Self-citationAnalysis of Forearm Rotational Motion Using Biplane Fluoroscopic Intensity-Based 2D-3D Matching
Abe, S., Otake, Y., Tennma, Y., Hiasa, Y., Oka, K., Tanaka, H., Shigi, A., Miyamura, S., Sato, Y., & Murase, T. (2019) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2019.04.017 · Cited by 8
Metadata
- Authors
- Stiehl, J. B., Dennis, D. A., Komistek, R. D., & Keblish, P. A.
- Venue
- Clinical Orthopaedics and Related Research
- Published
- 1997-12
- Volume
- 345
- Issue
- 345
- Pages
- 60???66
- ISSN
- 0009-921X (ISSN-L)
- OpenAlex
- W2000175909
- Cited by
- 185
- References
- 4
- FWCI
- 4.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.