The DOI matches its Crossref record.
Migration, Particles, and Fluid Pressure: A Discussion of Causes of Prosthetic Loosening
Abstract
Distal migration of the femoral component of a total hip replacement by as little as 0.33 mm during the first 6 postoperative months is predictive of the need for revision many years later. Because the fate of the prostheses is defined so early, it is unlikely that wear particles initiate loosening. However, the progression from the stage of early migration to clinical loosening has unknown causes, of which particles may be one. Slight instability associated with migration will lead to locally high fluid pressures surrounding the migrating prosthesis. Recent experiments applied a moderate fluid pressure to an implant to bone interface. This induced osteocyte death near the implant and subsequent bone resorption. Thus, there is evidence that fluid pressure and ensuing flow could be a main cause of not only pain, but also osteolysis necessitating revision.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The role of macrophages in osteolysis of total joint replacement
Ingham, E., & Fisher, J. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.04.035 · Cited by 667
Aseptic loosening, not only a question of wear: A review of different theories
Sundfeldt, M., V Carlsson, L., B Johansson, C., Thomsen, P., & Gretzer, C. (2006) · Acta Orthopaedica · doi:10.1080/17453670610045902 · Cited by 622
The basic science of the subchondral bone
Madry, H., van Dijk, C. N., & Mueller‐Gerbl, M. (2010) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s00167-010-1054-z · Cited by 615
The Cellular and Molecular Biology of Periprosthetic Osteolysis
Purdue, P. E., Koulouvaris, P., Potter, H. G., Nestor, B. J., & Sculco, T. P. (2007) · Clinical Orthopaedics and Related Research · doi:10.1097/01.blo.0000238813.95035.1b · Cited by 372
Jacobs, J. J., Roebuck, K. A., Archibeck, M., Hallab, N. J., & Glant, T. T. (2001) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-200112000-00008 · Cited by 367
Metadata
- Authors
- Aspenberg, P., & der Vis, H. V.
- Venue
- Clinical Orthopaedics and Related Research
- Published
- 1998-07
- Volume
- 352
- Issue
- 352
- Pages
- 75???80
- ISSN
- 0009-921X (ISSN-L)
- OpenAlex
- W2109897832
- Cited by
- 179
- References
- 0
- FWCI
- 5.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Migration, Particles, and Fluid Pressure: A Discussion of Causes of Prosthetic Loosening. https://app.cochat.ai/papers/10.1097/00003086-199807000-00010
- The paper
- Aspenberg, P., & der Vis, H. V. (1998). Migration, Particles, and Fluid Pressure: A Discussion of Causes of Prosthetic Loosening. Clinical Orthopaedics and Related Research. https://doi.org/10.1097/00003086-199807000-00010
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.