The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Computer Assisted Knee Replacement
Abstract
Accurate alignment of knee implants is essential for the success of total knee replacement. Although mechanical alignment guides have been designed to improve alignment accuracy, there are several fundamental limitations of this technology that will inhibit additional improvements. Various computer assisted techniques have been developed to examine the potential to install knee implants more accurately and consistently than can be done with mechanical guides. For example, computer integrated instrumentation incorporates highly accurate measurement devices to locate joint centers, track surgical tools, and align prosthetic components. Image guided knee replacement provides a three-dimensional preoperative plan that guides the placement of the cutting blocks and prosthetic components. Robot assisted knee replacement allows one to machine bones accurately without the use of standard cutting blocks. The rationale for the development of computer assisted knee replacement systems is presented, the operation of several different systems is described, the advantages and disadvantages of different approaches are discussed, and areas for future research are suggested.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Computational Approach to Edge Detection
Canny, J. (1986) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.1986.4767851 · Cited by 30,004
Cited by
Bäthis, H., Perlick, L., Tingart, M., Lüring, C., Zurakowski, D., & Grifka, J. (2004) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.86b5.14927 · Cited by 667
Computer-assisted Orthopedic Surgery
Sugano, N. (2003) · Journal of Orthopaedic Science · doi:10.1007/s10776-002-0623-6 · Cited by 184
Computer Assisted Knee Replacement Surgery: Is the Movement Mainstream?
Picard, F. (2014) · Orthopedic & Muscular System · doi:10.4172/2161-0533.1000153 · Cited by 23
Self-citation
Metadata
- Authors
- Delp, S. L., Stulberg, D. S., Davies, B., Picard, F., & Leitner, F.
- Venue
- Clinical Orthopaedics and Related Research
- Published
- 1998-09
- Volume
- 354
- Issue
- 354
- Pages
- 49-56
- ISSN
- 0009-921X (ISSN-L)
- OpenAlex
- W1989260135
- Cited by
- 336
- References
- 1
- FWCI
- 9.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Computer Assisted Knee Replacement. https://app.cochat.ai/papers/10.1097/00003086-199809000-00007
- The paper
- Delp, S. L., Stulberg, D. S., Davies, B., Picard, F., & Leitner, F. (1998). Computer Assisted Knee Replacement. Clinical Orthopaedics and Related Research. https://doi.org/10.1097/00003086-199809000-00007
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.