Primary and Revision Total Hip Replacement Using the Robodoc?? System
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
The ROBODOC system was designed to address potential human errors in performing cementless total hip replacement. The system consists of a preoperative planning computer workstation (called ORTHODOC) and a five-axis robotic arm with a high speed milling device as an end effector. The combined experience of the United States Food and Drug Administration multicenter trial and the German postmarket use of the system are reported. The United States study is controlled and randomized with 136 hip replacements performed at three centers (65 ROBODOC and 62 control). Followup was 1 year on 127 hip replacements and 2 years on 93 hip replacements. No differences were found in the Harris hip scores or the Short Form Health Survey outcomes questionnaire. Length of stay also was not different, but the surgical time and blood loss were greater in the ROBODOC group. This was attributed to a learning curve at each center. Radiographs were evaluated by an independent bone radiologist and showed statistically better fit and positioning of the femoral component in the ROBODOC group. Complications were not different, except for three cases of intraoperative femoral fracture in the control group and none in the ROBODOC group. The German study reports on 858 patients, 42 with bilateral hip replacements and this includes 30 revision cases for a total of 900 hip replacements. The Harris hip score rose from 43.7 to 91.5. In these cases the surgical time declined quickly from 240 minutes for the first case to 90 minutes. No intraoperative femoral fractures occurred in 900 cases. Other complications were comparable with total hip replacements performed using conventional techniques. The ROBODOC system is thought to be safe and effective in producing radiographically superior implant fit and positioning while eliminating femoral fractures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Anatomic Basis of Femoral Component Design
NOBLE, P. C., ALEXANDER, J. W., LINDAHL, L. J., YEW, D. T., GRANBERRY, W. M., & TULLOS, H. S. (1988) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198810000-00015 · Cited by 777
Development of a Surgical Robot for Cementless Total Hip Arthroplasty
PAUL, H. A., BARGAR, W. L., MITTLESTADT, B., MUSITS, B., TAYLOR, R. H., LZANZIDES, P., ZUHARS, J., WILLIAMSON, B., & HANSON, W. (1992) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199212000-00010 · Cited by 345
Self-citationCurrent Concepts in Orthopaedic Biomaterials and Implant Fixation
FRIEDMAN, R. J., BLACK, J., GALANTE, J. O., JACOBS, J. J., & SKINNER, H. B. (1993) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199307000-00017 · Cited by 210
Cited by
Cobb, J., Henckel, J., Gomes, P., Harris, S., Jakopec, M., Rodriguez, F., Barrett, A., & Davies, B. (2006) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.88b2.17220 · Cited by 333
Evolution of autonomous and semi‐autonomous robotic surgical systems: a review of the literature
Moustris, G. P., Hiridis, S. C., Deliparaschos, K. M., & Konstantinidis, K. M. (2011) · The International Journal of Medical Robotics and Computer Assisted Surgery · doi:10.1002/rcs.408 · Cited by 321
Medical Robots: Current Systems and Research Directions
Beasley, R. A. (2012) · Journal of Robotics · doi:10.1155/2012/401613 · Cited by 312
Howe, R. D., & Matsuoka, Y. (1999) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.1.1.211 · Cited by 282
Hendel, M. D., Bryan, J. A., Barsoum, W. K., Rodriguez, E. J., Brems, J. J., Evans, P. J., & Iannotti, J. P. (2012) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.k.01209 · Cited by 252
Park, S. E., & Lee, C. T. (2007) · The Journal of Arthroplasty · doi:10.1016/j.arth.2007.05.036 · Cited by 235
“The idea of using a robot in the field of orthopedic surgery, especially for total hip arthroplasty (THA), originated in the United States in the early 1990s [9,10].”
BackgroundIn Touch with Robotics: Neurosurgery for the Future
Nathoo, N., Çavuşoğlu, M. C., Vogelbaum, M. A., & Barnett, G. H. (2005) · Neurosurgery · doi:10.1227/01.neu.0000153929.68024.cf · Cited by 221
“The incorporation of robotic technology in the neurosurgical operating room seems to be imminent, as surgical benefits have been quantified for recent robot-assisted interventions (2, 5, 12, 14, 22, 28, 30, 33, 38, 40, 41, 44, 50, 52, 58, 61, 66).”
Frontiers of Medical Robotics: From Concept to Systems to Clinical Translation
Troccaz, J., Dagnino, G., & Yang, G.-Z. (2019) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-060418-052502 · Cited by 194
Computer-assisted Orthopedic Surgery
Sugano, N. (2003) · Journal of Orthopaedic Science · doi:10.1007/s10776-002-0623-6 · Cited by 184
“The goals of CAS are to (1) eliminate outliers from radiological results by improving the accuracy of surgical procedures; (2) make minimum invasive surgery easier; (3) explore new concepts in surgery; and (4) use CAS for training and education.”
BackgroundNavigation in Endoscopic Soft Tissue Surgery: Perspectives and Limitations
Baumhauer, M., Feuerstein, M., Meinzer, H.-P., & Rassweiler, J. (2008) · Journal of Endourology · doi:10.1089/end.2007.9827 · Cited by 181
“19,20 Shortly after that, systems for navigated hip 21 and knee 22 replacement followed.”
Robot-assisted Total Knee Arthroplasty
Bellemans, J., Vandenneucker, H., & Vanlauwe, J. (2007) · Clinical Orthopaedics & Related Research · doi:10.1097/blo.0b013e318126c0c0 · Cited by 178
“Although most of the initial research and development was performed in Germany, the enthusiasm spread throughout not only Europe, but also North America and the rest of the world.(1,2,6,7,10,14,15) Today for example, robots are not only used in hip arthroplasty, but also in knee arthroplasty and cruciate ligament surg…”
BackgroundSchulz, A. P., Seide, K., Queitsch, C., von Haugwitz, A., Meiners, J., Kienast, B., Tarabolsi, M., Kammal, M., & Jürgens, C. (2007) · The International Journal of Medical Robotics and Computer Assisted Surgery · doi:10.1002/rcs.161 · Cited by 165
Autonomy in surgical robots and its meaningful human control
Ficuciello, F., Tamburrini, G., Arezzo, A., Villani, L., & Siciliano, B. (2019) · Paladyn, Journal of Behavioral Robotics · doi:10.1515/pjbr-2019-0002 · Cited by 92
Metadata
- Authors
- Bargar, W. L., Bauer, A., & B??rner, M.
- Venue
- Clinical Orthopaedics and Related Research
- Published
- 1998-09
- Volume
- 354
- Issue
- 354
- Pages
- 82-91
- ISSN
- 0009-921X (ISSN-L)
- OpenAlex
- W2087256467
- Cited by
- 419
- References
- 3
- FWCI
- 10.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.