The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Navigation in Endoscopic Soft Tissue Surgery: Perspectives and Limitations
Abstract
Despite rapid developments in the research areas of medical imaging, medical image processing, and robotics, the use of computer assistance in surgical routine is still limited to diagnostics, surgical planning, and interventions on mostly rigid structures. In order to establish a computer-aided workflow from diagnosis to surgical treatment and follow-up, several proposals for computer-assisted soft tissue interventions have been made in recent years. By means of different pre- and intraoperative information sources, such as surgical planning, intraoperative imaging, and tracking devices, surgical navigation systems aim to support surgeons in localizing anatomical targets, observing critical structures, and sparing healthy tissue. Current research in particular addresses the problem of organ shift and tissue deformation, and obstacles in communication between navigation system and surgeon. In this paper, we review computer-assisted navigation systems for soft tissue surgery. We concentrate on approaches that can be applied in endoscopic thoracic and abdominal surgery, because endoscopic surgery has special needs for image guidance due to limitations in perception. Furthermore, this paper informs the reader about new trends and technologies in the area of computer-assisted surgery. Finally, a balancing of the key challenges and possible benefits of endoscopic navigation refines the perspectives of this increasingly important discipline of computer-aided medical procedures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Three-dimensional ultrasound imaging
Fenster, A., Downey, D. B., & Cardinal, H. N. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/5/201 · Cited by 812
Computer-assisted Orthopedic Surgery
Sugano, N. (2003) · Journal of Orthopaedic Science · doi:10.1007/s10776-002-0623-6 · Cited by 184
Cited by
The status of augmented reality in laparoscopic surgery as of 2016
Bernhardt, S., Nicolau, S. A., Soler, L., & Doignon, C. (2017) · Medical Image Analysis · doi:10.1016/j.media.2017.01.007 · Cited by 314
Advanced Medical Displays: A Literature Review of Augmented Reality
Sielhorst, T., Feuerstein, M., & Navab, N. (2008) · Journal of Display Technology · doi:10.1109/jdt.2008.2001575 · Cited by 308
Self-citationOptical techniques for 3D surface reconstruction in computer-assisted laparoscopic surgery
Maier-Hein, L., Mountney, P., Bartoli, A., Elhawary, H., Elson, D., Groch, A., Kolb, A., Rodrigues, M., Sorger, J., Speidel, S., et al. (2013) · Medical Image Analysis · doi:10.1016/j.media.2013.04.003 · Cited by 280
Vision-based and marker-less surgical tool detection and tracking: a review of the literature
Bouget, D., Allan, M., Stoyanov, D., & Jannin, P. (2017) · Medical Image Analysis · doi:10.1016/j.media.2016.09.003 · Cited by 277
A Review of Recent Advances in Registration Techniques Applied to Minimally Invasive Therapy
Liao, R., Zhang, L., Sun, Y., Miao, S., & Chefd'Hotel, C. (2013) · IEEE Transactions on Multimedia · doi:10.1109/tmm.2013.2244869 · Cited by 71
Metadata
- Authors
- Baumhauer, M., Feuerstein, M., Meinzer, H.-P., & Rassweiler, J.
- Venue
- Journal of Endourology
- Publisher
- SAGE Publications
- Published
- 2008-04
- Volume
- 22
- Issue
- 4
- Pages
- 751-766
- ISSN
- 0892-7790 (ISSN-L)
- 1557-900X
- OpenAlex
- W1981021845
- Cited by
- 181
- References
- 2
- FWCI
- 13.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Navigation in Endoscopic Soft Tissue Surgery: Perspectives and Limitations. https://app.cochat.ai/papers/10.1089/end.2007.9827
- The paper
- Baumhauer, M., Feuerstein, M., Meinzer, H.-P., & Rassweiler, J. (2008). Navigation in Endoscopic Soft Tissue Surgery: Perspectives and Limitations. Journal of Endourology. https://doi.org/10.1089/end.2007.9827
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.