Applied Biomechanics of the Patella
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
Although numerous prominent orthopaedists of the twentieth century considered the patella to be useless, even detrimental, it now is clear that the patella serves an important biomechanical function. It is a complex lever that magnifies the moment arm of the extensor mechanism. The patellofemoral contact area (the fulcrum of the lever) shifts along a proximodistal axis through the knee's arc of motion. As the knee flexes, the force within the patellar tendon diminishes relative to that of the quadriceps tendon. One's interpretation of patellar tracking is dependent on the choice of coordinates. When assessing tracking by way of anatomic coordinates, patellas are seen to be slightly lateralized at 0 degrees flexion and to follow similar paths down the trochlea. The tracking pattern is the result of an elaborate interplay between the quadriceps muscles, patellofemoral ligaments, the geometry of the trochlea, and the quadriceps angle. The articular cartilage of the patella is the thickest in the human body and does not follow the contour of the subchondral bone. Patellar cartilage is softer and more permeable than that of the trochlea. It is insensate. In size, nature, and number, the facets of the patellar articulation vary from person to person.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cartilage and diarthrodial joints as paradigms for hierarchical materials and structures
Mow, V. C., Ratcliffe, A., & Robin Poole, A. (1992) · Biomaterials · doi:10.1016/0142-9612(92)90001-5 · Cited by 956
Patellofemoral contact pressures. The influence of q-angle and tendofemoral contact.
Huberti, H. H., & Hayes, W. C. (1984) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198466050-00010 · Cited by 840
Medial Soft Tissue Restraints in Lateral Patellar Instability and Repair
Hautamaa, P. V., Fithian, D. C., Kaufman, K. R., Daniel, D. M., & Pohlmeyer, A. M. (1998) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199804000-00021 · Cited by 563
Wibeeg, G. (1941) · Acta Orthopaedica Scandinavica · doi:10.3109/17453674108988818 · Cited by 526
Biomechanics of the knee-extension exercise. Effect of cutting the anterior cruciate ligament.
Grood, E. S., Suntay, W. J., Noyes, F. R., & Butler, D. L. (1984) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198466050-00011 · Cited by 387
A mathematical model of the patellofemoral joint
van Eijden, T. M. G. J., Kouwenhoven, E., Verburg, J., & Weijs, W. A. (1986) · Journal of Biomechanics · doi:10.1016/0021-9290(86)90154-5 · Cited by 321
Force ratios in the quadriceps tendon and ligamentum patellae
Huberti, H. H., Hayes, W. C., Stone, J. L., & Shybut, G. T. (1984) · Journal of Orthopaedic Research · doi:10.1002/jor.1100020108 · Cited by 273
The three‐dimensional tracking pattern of the human patella
van Kampen, A., & Huiskes, R. (1990) · Journal of Orthopaedic Research · doi:10.1002/jor.1100080309 · Cited by 228
Ahmed, A. M., Burke, D. L., & Yu, A. (1983) · Journal of Biomechanical Engineering · doi:10.1115/1.3138410 · Cited by 225
Anatomy and surface geometry of the patellofemoral joint in the axial plane
Stäubli, H.-U., Dürrenmatt, U., Porcellini, B., & Rauschning, W. (1999) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.81b3.0810452 · Cited by 209
Cited by
Measurement of Patellar Tracking: Assessment and Analysis of the Literature
Katchburian, M. V., Bull, A. M. J., Shih, Y.-F., Heatley, F. W., & Amis, A. A. (2003) · Clinical Orthopaedics & Related Research · doi:10.1097/01.blo.0000068767.86536.9a · Cited by 273
Luyckx, T., Didden, K., Vandenneucker, H., Labey, L., Innocenti, B., & Bellemans, J. (2009) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.91b3.21592 · Cited by 174
Relationship between Patellar Tracking and the “Screw‐home” Mechanism of Tibiofemoral Joint
Zhang, L., Wang, X., Niu, Y., Liu, H., & Wang, F. (2016) · Orthopaedic Surgery · doi:10.1111/os.12295 · Cited by 34
Patellar Tracking during the Gait Cycle
Abbas, G., & Diss, C. (2011) · Journal of orthopaedic surgery · doi:10.1177/230949901101900305 · Cited by 9
“uk Journal of Orthopaedic Surgery 2011;19(3):288-91”
Metadata
- Authors
- Grelsamer, R. P., & Weinstein, C. H.
- Venue
- Clinical Orthopaedics and Related Research
- Published
- 2001-08
- Volume
- 389
- Issue
- 389
- Pages
- 9-14
- ISSN
- 0009-921X (ISSN-L)
- OpenAlex
- W1991837137
- Cited by
- 169
- References
- 21
- FWCI
- 2.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Applied Biomechanics of the Patella. https://app.cochat.ai/papers/10.1097/00003086-200108000-00003
- The paper
- Grelsamer, R. P., & Weinstein, C. H. (2001). Applied Biomechanics of the Patella. Clinical Orthopaedics and Related Research. https://doi.org/10.1097/00003086-200108000-00003
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.