Why Are Total Knee Arthroplasties Failing Today?
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
The incidence of failure after knee replacement is low, yet it has been reported that more than 22,000 knee replacements are revised yearly. The purpose of the current study was to determine current mechanisms of failure of total knee arthroplasties. A retrospective review was done on all patients who had revision total knee arthroplasty during a 3-year period (September 1997-October 2000) at one institution. The preoperative evaluation in conjunction with radiographs, laboratory data, and intraoperative findings were used to determine causes of failure. Two hundred twelve surgeries were done on 203 patients (nine patients had bilateral surgeries). The reasons for failure listed in order of prevalence among the patients in this study include polyethylene wear, aseptic loosening, instability, infection, arthrofibrosis, malalignment or malposition, deficient extensor mechanism, avascular necrosis in the patella, periprosthetic fracture, and isolated patellar resurfacing. The cases reviewed included patients who had revision surgery within 9 days to 28 years (average, 3.7 years) after the previous surgery. More than half of the revisions in this group of patients were done less than 2 years after the index operation. Fifty percent of early revision total knee arthroplasties in this series were related to instability, malalignment or malposition, and failure of fixation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Early Failures in Total Knee Arthroplasty
Fehring, T. K., Odum, S., Griffin, W. L., Mason, J. B., & Nadaud, M. (2001) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-200111000-00041 · Cited by 646
SEGAWA, H., TSUKAYAMA, D. T., KYLE, R. F., BECKER, D. A., & GUSTILO, R. B. (1999) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199910000-00008 · Cited by 446
Barrack, R. L., Bertot, A. J., Wolfe, M. W., Waldman, D. A., Milicic, M., & Myers, L. (2001) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200109000-00013 · Cited by 326
Comparison and quantitation of wear debris of failed total hip and total knee arthroplasty
Hirakawa, K., Bauer, T. W., Stulberg, B. N., & Wilde, A. H. (1996) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199606)31:2<257::aid-jbm13>3.0.co;2-i · Cited by 135
FRACTURE OF THE METAL TIBIAL TRAY AFTER KINEMATIC TOTAL KNEE REPLACEMENT
Abernethy, P. J., Robinson, C. M., & Fowler, R. M. (1996) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.78b2.0780220 · Cited by 53
Cited by
Periprosthetic Joint Infection: The Incidence, Timing, and Predisposing Factors
Pulido, L., Ghanem, E., Joshi, A., Purtill, J. J., & Parvizi, J. (2008) · Clinical Orthopaedics & Related Research · doi:10.1007/s11999-008-0209-4 · Cited by 1,366
The Epidemiology of Revision Total Hip Arthroplasty in the United States
Bozic, K. J., Kurtz, S. M., Lau, E., Ong, K., Vail, T. P., & Berry, D. J. (2009) · The Journal of Arthroplasty · doi:10.1016/j.arth.2008.11.033 · Cited by 1,275
The Epidemiology of Revision Total Knee Arthroplasty in the United States
Bozic, K. J., Kurtz, S. M., Lau, E., Ong, K., Chiu, V., Vail, T. P., Rubash, H. E., & Berry, D. J. (2010) · Clinical Orthopaedics & Related Research · doi:10.1007/s11999-009-0945-0 · Cited by 1,245
The significance of infection related to orthopedic devices and issues of antibiotic resistance
Campoccia, D., Montanaro, L., & Arciola, C. R. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.11.044 · Cited by 1,109
Choong, P. F., Dowsey, M. M., & Stoney, J. D. (2009) · The Journal of Arthroplasty · doi:10.1016/j.arth.2008.02.018 · Cited by 447
Why Are Total Knees Failing Today? Etiology of Total Knee Revision in 2010 and 2011
Schroer, W. C., Berend, K. R., Lombardi, A. V., Barnes, C. L., Bolognesi, M. P., Berend, M. E., Ritter, M. A., & Nunley, R. M. (2013) · The Journal of Arthroplasty · doi:10.1016/j.arth.2013.04.056 · Cited by 423
Koh, C. K., Zeng, I., Ravi, S., Zhu, M., Vince, K. G., & Young, S. W. (2017) · Clinical Orthopaedics & Related Research · doi:10.1007/s11999-017-5396-4 · Cited by 321
Mezger, U., Jendrewski, C., & Bartels, M. (2013) · Langenbeck's Archives of Surgery · doi:10.1007/s00423-013-1059-4 · Cited by 305
Bonner, T. J., Eardley, W. G. P., Patterson, P., & Gregg, P. J. (2011) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.93b9.26573 · Cited by 302
Strategies for Articular Cartilage Lesion Repair and Functional Restoration
Ahmed, T. A. E., & Hincke, M. T. (2010) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2009.0590 · Cited by 270
Liow, M. H. L., Xia, Z., Wong, M. K., Tay, K. J., Yeo, S. J., & Chin, P. L. (2014) · The Journal of Arthroplasty · doi:10.1016/j.arth.2013.12.010 · Cited by 265
Sterilization of implantable polymer-based medical devices: A review
Tipnis, N. P., & Burgess, D. J. (2018) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2017.12.003 · Cited by 233
Gandhi, R., Tsvetkov, D., Davey, J. R., & Mahomed, N. N. (2009) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.91b7.21702 · Cited by 194
Tsaras, G., Maduka-Ezeh, A., Inwards, C. Y., Mabry, T., Erwin, P. J., Murad, M. H., Montori, V. M., West, C. P., Osmon, D. R., & Berbari, E. F. (2012) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/jbjs.j.00756 · Cited by 158
Almouahed, S., Gouriou, M., Hamitouche, C., Stindel, E., & Roux, C. (2011) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2011.2159512 · Cited by 59
Computer Assisted Knee Replacement Surgery: Is the Movement Mainstream?
Picard, F. (2014) · Orthopedic & Muscular System · doi:10.4172/2161-0533.1000153 · Cited by 23
Metadata
- Authors
- Sharkey, P. F., Hozack, W. J., Rothman, R. H., Shastri, S., & Jacoby, S. M.
- Venue
- Clinical Orthopaedics and Related Research
- Published
- 2002-11
- Volume
- 404
- Issue
- 404
- Pages
- 7-13
- ISSN
- 0009-921X (ISSN-L)
- OpenAlex
- W2056068954
- Cited by
- 1,354
- References
- 5
- FWCI
- 18.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.