The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
The Use of Piezoceramics As Electrical Energy Harvesters Within Instrumented Knee Implant During Walking
Open accessAbstract
The goal of our paper is to quantify the electrical energy that can be harvested within a new generation of instrumented knee implant during normal walking. This generation of knee implant is proposed to assess the in vivo anteroposterior and mediolateral distributions of tibiofemoral force on the tibial baseplate without the need to be powered from an external source of energy. The proposed self-powered diagnostic knee implant can provide the clinicians with useful information on the sagittal and coronal instabilities of the prosthetic knee throughout its lifespan. Four piezoelectric elements were embedded within the anteromedial, posteromedial, anterolateral, and posterolateral compartments of the tibial baseplate. These elements can simultaneously be used to sense the force distribution and generate the electric power needed to supply the acquisition, processing, and transmission system located in the stem of the implant. In order to study the power generation issue, OrCAD/PSpice and MATLAB/Simulink models of the piezoelectric element have been developed to quantify the electrical energy harvested under operating conditions close to those encountered in vivo during normal walking. Furthermore, an experimental prototype of the self-powered diagnostic knee implant has been designed, developed, and tested in our laboratory (LaTIM, INSERM U650, Brest, France) in order to validate the modeling results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“the piezoelectric elements as energy harvesters are proper for low frequencies conditions and the power output of this technology is not enough to power high-consumption devices [27] and limited to nearly 100 mW due to the small displacement and the high generated voltage [28].”
From A review of walking energy harvesting using piezoelectric materials (2017) · cites this paper as [27]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Why Are Total Knee Arthroplasties Failing Today?
Sharkey, P. F., Hozack, W. J., Rothman, R. H., Shastri, S., & Jacoby, S. M. (2002) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-200211000-00003 · Cited by 1,355
Energy scavenging with shoe-mounted piezoelectrics
Shenck, N. S., & Paradiso, J. A. (2001) · IEEE Micro · doi:10.1109/40.928763 · Cited by 1,091
Piezoelectric Crystals and Their Applications to Ultrasonics
Mason, W. P., & Baerwald, H. G. (1951) · Physics Today · doi:10.1063/1.3067231 · Cited by 936
Piezoelectric Sensors and Sensor Materials
Tressler, J. F., Alkoy, S., & Newnham, R. E. (1998) · Journal of Electroceramics · doi:10.1023/a:1009926623551 · Cited by 716
Towards a piezoelectric vibration-poweredmicrogenerator
Glynne‐Jones, P., Beeby, S., & White, N. M. (2001) · IEE Proceedings - Science Measurement and Technology · doi:10.1049/ip-smt:20010323 · Cited by 355
Flexion Instability After Primary Posterior Cruciate Retaining Total Knee Arthroplasty
Pagnano, M. W., Hanssen, A. D., Lewallen, D. G., & Stuart, M. J. (1998) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199811000-00008 · Cited by 309
On Low-Frequency Electric Power Generation With PZT Ceramics
Platt, S. R., Farritor, S. M., & Haider, H. (2005) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2005.844704 · Cited by 294
Generation of electrical energy for portable devices
Poulin, G., Sarraute, E., & Costa, F. (2004) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2004.05.013 · Cited by 277
Cady, W. G. (1978) · Virtual Defense Library (Ministerio de Defensa) · Cited by 269
Trends in cardiac pacemaker batteries.
Mallela, V. S., Ilankumaran, V., & Rao, N. S. (2004) · PubMed · Cited by 244
Research works printed but not linked: 3
- 2004, Implants for SurgeryWear of Total Knee-joint ProsthesesPart 3 Loading and Displacement Parameters for Wear-testing Machines With Displacement Control and Corresponding Environmental Conditions for Test
- morrison, 1968, Bio-engineering analysis of force actions transmitted by the knee joint, Biomed Eng, 3, 164
- 2002, Implants for SurgeryWear of Total Knee-joint ProsthesesPart 1 Loading and Displacement Parameters for Wear-testing Machines With Load Control and Corresponding Environmental Conditions for Test
Cited by
Sorted by citations
Safaei, M., Sodano, H. A., & Anton, S. R. (2019) · Smart Materials and Structures · doi:10.1088/1361-665x/ab36e4 · Cited by 874
“Author Device Energy Source Transducer Type Generator Material Input Excitation Verification Method Output Power Almouahed et al [402] Piezoelectric tibial tray Knee motion Stack NCE51 (PZT-5A) Normal gait In vitro test 4.27 mW Holmberg et al [403] Battery-less knee implant Knee motion Stack TS18-H5-104 Normal gait In…”
BackgroundInfluentialA review of walking energy harvesting using piezoelectric materials
Nia, E. M., Zawawi, N. A. W. A., & Singh, B. S. M. (2017) · IOP Conference Series: Materials Science and Engineering · doi:10.1088/1757-899x/291/1/012026 · Cited by 97
“However, the piezoelectric elements as energy harvesters are proper for low frequencies conditions and the power output of this technology is not enough to power high-consumption devices [27] and limited to nearly 100 mW due to the small displacement and the high generated voltage [28].”
Background
Metadata
- Authors
- Almouahed, S., Gouriou, M., Hamitouche, C., Stindel, E., & Roux, C.
- Affiliations
- Laboratoire de Traitement de l'Information Médicale (FR)
- ORCID
- Almouahed, Shaban
- Venue
- IEEE/ASME Transactions on Mechatronics
- Published
- 2011-10
- Volume
- 16
- Issue
- 5
- Pages
- 799-807
- ISSN
- 1083-4435 (ISSN-L)
- 1941-014X
- OpenAlex
- W2145409536
- Cited by
- 59
- References
- 20
- Citations by year
- 2026: 2 · 2025: 2 · 2023: 2 · 2022: 2 · 2021: 6 · 2020: 1 · 2019: 5 · 2018: 5 · 2017: 6 · 2016: 4 · 2015: 8 · 2014: 7 · 2013: 7 · 2012: 2
- FWCI
- 9.07
- Type
- journal article
- Language
- en
- Open access
- green
- hal.science
- Locations
- IEEE/ASME Transactions on Mechatronics (publishedVersion)
- HAL (submittedVersion, other-oa)
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Innovative Energy Harvesting Technologies
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Health Sciences › Medicine › Surgery › Orthopaedic implants and arthroplasty
- Keywords
- piezoelectric energy harvesting, tibial baseplate, walking, piezoelectric modeling
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Use of Piezoceramics As Electrical Energy Harvesters Within Instrumented Knee Implant During Walking. https://app.cochat.ai/papers/10.1109/tmech.2011.2159512
- The paper
- Almouahed, S., Gouriou, M., Hamitouche, C., Stindel, E., & Roux, C. (2011). The Use of Piezoceramics As Electrical Energy Harvesters Within Instrumented Knee Implant During Walking. IEEE/ASME Transactions on Mechatronics. https://doi.org/10.1109/tmech.2011.2159512