Tear Film Lipid Layer Thickness as a Function of Blinking
The DOI matches its Crossref record.
Abstract
Alterations in the tear film lipid layer as a function of blinking were investigated using a custom-designed specular reflection monitoring system. The tear film lipid layer of 104 subjects under conditions of normal ("baseline") blinking and "forceful" blinking was quantitated on the basis of specific interference colors. Deliberate, forceful blinking was found to significantly increase the lipid layer thickness (LLT) of the tear film. The magnitude of increase was found to be correlated with the baseline LLT values; individuals with baseline LLT values of 75-150 nm demonstrated a mean increase in LLT of 33 nm following forceful blinking, whereas subjects with baseline LLT values < or = 60 nm experienced a mean increase of 19 nm. The difference in the magnitude of increase between the groups was highly significant (p = 0.0001). The data suggest that, in addition to playing a role in the spreading of lipid across the tear film, the blinking mechanism may be important in the maintenance of the lipid layer by augmenting the expression of lipids from the meibomian glands.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Knop, E., Knop, N., Millar, T., Obata, H., & Sullivan, D. A. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.10-6997c · Cited by 1,061
The International Workshop on Meibomian Gland Dysfunction: Report of the Diagnosis Subcommittee
Tomlinson, A., Bron, A. J., Korb, D. R., Amano, S., Paugh, J. R., Pearce, E. I., Yee, R., Yokoi, N., Arita, R., & Dogru, M. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.10-6997f · Cited by 855
Self-citationFunctional aspects of the tear film lipid layer
Bron, A. J., Tiffany, J. M., Gouveia, S. M., Yokoi, N., & Voon, L. W. (2004) · Experimental Eye Research · doi:10.1016/j.exer.2003.09.019 · Cited by 782
Foulks, G. N., & Bron, A. J. (2003) · The Ocular Surface · doi:10.1016/s1542-0124(12)70139-8 · Cited by 519
The Ocular Surface and Tear Film and Their Dysfunction in Dry Eye Disease
Rolando, M., & Zierhut, M. (2001) · Survey of Ophthalmology · doi:10.1016/s0039-6257(00)00203-4 · Cited by 366
Driver, P. J., & Lemp, M. A. (1996) · Survey of Ophthalmology · doi:10.1016/s0039-6257(96)80064-6 · Cited by 324
Changes in the tear film and ocular surface from dry eye syndrome
Johnson, M. E., & Murphy, P. J. (2004) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2004.04.003 · Cited by 297
Moon, J. H., Kim, K. W., & Moon, N. J. (2016) · BMC Ophthalmology · doi:10.1186/s12886-016-0364-4 · Cited by 292
The challenge of dry eye diagnosis
Savini, G. (2008) · Clinical Ophthalmology · doi:10.2147/opth.s1496 · Cited by 286
Wolkoff, P., Nøjgaard, J. K., Troiano, P., & Piccoli, B. (2005) · Occupational and Environmental Medicine · doi:10.1136/oem.2004.016030 · Cited by 259
Understanding and Analyzing Meibomian Lipids—A Review
Butovich, I. A., Millar, T. J., & Ham, B. M. (2008) · Current Eye Research · doi:10.1080/02713680802018419 · Cited by 203
ACOSTA, M. C., GALLAR, J., & BELMONTE, C. (1999) · Experimental Eye Research · doi:10.1006/exer.1998.0656 · Cited by 182
Trunfio-Sfarghiu, A.-M., Berthier, Y., Meurisse, M.-H., & Rieu, J.-P. (2008) · Langmuir · doi:10.1021/la8005234 · Cited by 109
Metadata
- Authors
- Korb, D. R., Baron, D. F., Herman, J. P., Finnemore, V. M., Exford, J. M., Hermosa, J. L., Leahy, C. D., Glonek, T., & Greiner, J. V.
- Venue
- Cornea
- Published
- 1994-07
- Volume
- 13
- Issue
- 4
- Pages
- 354-359
- ISSN
- 0277-3740 (ISSN-L)
- OpenAlex
- W2001866016
- Cited by
- 225
- References
- 0
- FWCI
- 1.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.