Quantitation of Ultraviolet Light-Absorbing Fractions of the Cornea
The DOI matches its Crossref record.
Abstract
This study attempts to measure the quantitative contribution of major chemical fractions of the whole bovine cornea to ultraviolet (UV) absorption between 240 and 300 nm, with special attention to the biologically significant range of 290-300 nm. The cornea was divided into water-insoluble, nonprotein small water-soluble, water-soluble protein, and lipid-soluble fractions. The insoluble fraction (largely collagen) was solubilized by enzymatic digestion. Solutions of individual fractions equivalent to a constant mass of fresh cornea were scanned for absorption from 240 to 300 nm. The sum of the absorbances of the individual fractions closely approximated the absorbance of whole corneas at all wavelengths examined. The extinction coefficients of the lipid and water-soluble fractions were several times greater than that of the insoluble fraction throughout the studied spectrum. Yet, because of its large mass (75% of cornea dry weight), the insoluble fraction accounted for 40-50% of UV absorbance between 240 and 280 nm. However, in the range of 290-300 nm, the water-soluble plus lipid-soluble fractions accounted for 60-65% of the total absorption, with the water-soluble proteins alone accounting for 40-45% of the total. The soluble proteins comprised only approximately 17% of the cornea's dry weight. The special contribution of the water-soluble proteins to absorption was attributed to their relatively high tryptophan content (approximately 1.6% by weight). A 54-kDa protein, identified by others as tryptophan-rich, tumor-associated aldehyde dehydrogenase, accounted for approximately 30% of the total soluble protein mass.(ABSTRACT TRUNCATED AT 250 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The cellular basis of corneal transparency: evidence for 'corneal crystallins'
Jester, J. V., Moller-Pedersen, T., Huang, J., Sax, C. M., Kays, W. T., Cavangh, H. D., Petroll, W. M., & Piatigorsky, J. (1999) · Journal of Cell Science · doi:10.1242/jcs.112.5.613 · Cited by 503
Characteristics of the Human Ocular Surface Epithelium
Kinoshita, S., Adachi, W., Sotozono, C., Nishida, K., Yokoi, N., Quantock, A. J., & Okubo, K. (2001) · Progress in Retinal and Eye Research · doi:10.1016/s1350-9462(01)00007-6 · Cited by 265
Corneal crystallins and the development of cellular transparency
Jester, J. V. (2008) · Seminars in Cell & Developmental Biology · doi:10.1016/j.semcdb.2007.09.015 · Cited by 189
“Overall, water-soluble proteins from the cornea while accounting for 20% of the total protein may account for over 50% of the total UVB-light absorption, and have been called “absorbins” by some investigators [25].”
BackgroundGene sharing in lens and cornea: facts and implications
Piatigorsky, J. (1998) · Progress in Retinal and Eye Research · doi:10.1016/s1350-9462(97)00004-9 · Cited by 159
Interaction of ultraviolet light with the cornea: clinical implications for corneal crosslinking
Lombardo, M., Pucci, G., Barberi, R., & Lombardo, G. (2015) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2014.12.013 · Cited by 62
Metadata
- Authors
- Mitchell, J., & Cenedella, R. J.
- Venue
- Cornea
- Published
- 1995-05
- Volume
- 14
- Issue
- 3
- Pages
- 266-272
- ISSN
- 0277-3740 (ISSN-L)
- OpenAlex
- W2048964006
- Cited by
- 48
- References
- 0
- FWCI
- 3.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quantitation of Ultraviolet Light-Absorbing Fractions of the Cornea. https://app.cochat.ai/papers/10.1097/00003226-199505000-00007
- The paper
- Mitchell, J., & Cenedella, R. J. (1995). Quantitation of Ultraviolet Light-Absorbing Fractions of the Cornea. Cornea. https://doi.org/10.1097/00003226-199505000-00007
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.