Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 186

The DOI matches its Crossref record.

Deep Lamellar Keratoplasty Versus Penetrating Keratoplasty for Corneal Lesions

Panda, Anita, Bageshwar, Lalit Mohan Singh, Ray, Manotosh, Singh, J. P., Kumar, Abhiyan · 1999 · Cornea

Abstract

PURPOSE: To compare the effectiveness of deep lamellar keratoplasty (DLK) with that of penetrating keratoplasty (PKP) in cases of corneal lesions not involving the endothelium. METHODS: Forty-eight eyes with leukomatous corneal opacity (n = 33), keratoconus with apical scarring (n = 6), granular corneal dystrophy (n = 5), lattice corneal dystrophy (n = 2), and multiple corneal foreign bodies (n = 2) in an age group varying from 16 to 53 years underwent DLK (n = 24) and PKP (n = 24) by utilizing B and (B+ and A) grade M-K preserved donor tissue, respectively. The patients were followed up closely, and the graft clarity, visual achievement, astigmatism and endothelial cell count were evaluated at repeated occasions up to 1 year. RESULTS: Astigmatism of <3 diopters (D) and > or = 5D was obtained in 19 eyes and one eye, respectively, after DLK at 6 months, whereas six eyes of the PKP group had astigmatism <3D, and 12 eyes had > or = 5D at the end of 6 months. The same at 1 year was observed in 20 and one eye in the DLK and eight and five eyes of the PKP group. Astigmatism of > or = 5D at the end of 6 months in both the groups showed highly significant changes (p < 0.001). Best corrected visual acuity of 6/18 or more was achieved in 18 and 12 eyes at 6 months after DLK and PKP, respectively, which were statistically highly significant (p < 0.001), whereas at 1 year, it was seen in 17 and 15 eyes of the DLK and PKP groups, respectively, which was nonsignificant. The mean endothelial cell count was 2,233.3+/-64.453 cells/mm2 and 2,219.6+/-102.48 cells/mm2 at 6 months and I year, respectively, after DLK, which was nonsignificant. The mean cell count of the donor eyes used for PKP was 2,191+/-52.164 cells/mm2, 1,902.8+/-70.346 cells/mm2 at 6 months, and 1,579.0+/-80.24 cells/mm2 at 1 year. All the values showed highly significant changes (p < 0.001). Further, the graft clarity of > or = 3+ was achieved in 20 and 18 eyes at 6 months postoperatively in the DLK and PKP groups, whereas the same was observed in 19 and 13 eyes of both the groups, respectively, at 1-year follow-up. CONCLUSION: DLK is a promising procedure and should be practiced more frequently for corneal pathology not involving the endothelium.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00003226-199903000-00005

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 186

Metadata

Authors
Panda, A., Bageshwar, L. M. S., Ray, M., Singh, J. P., & Kumar, A.
Venue
Cornea
Published
1999-03
Volume
18
Issue
2
Pages
172
ISSN
0277-3740 (ISSN-L)
OpenAlex
W2000906677
Cited by
186
References
0
FWCI
3.34
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Deep Lamellar Keratoplasty Versus Penetrating Keratoplasty for Corneal Lesions. https://app.cochat.ai/papers/10.1097/00003226-199903000-00005
The paper
Panda, A., Bageshwar, L. M. S., Ray, M., Singh, J. P., & Kumar, A. (1999). Deep Lamellar Keratoplasty Versus Penetrating Keratoplasty for Corneal Lesions. Cornea. https://doi.org/10.1097/00003226-199903000-00005

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.