The DOI matches its Crossref record.
Thermal and Biomechanical Parameters of Porcine Cornea
Abstract
PURPOSE: New methods in refractive surgery require a considerable understanding of the material "cornea" and are often studied by theoretical modeling in order to gain insight into the procedure and an optimized approach to the technique. The quality of these models is highly dependent on the preciseness of its input parameters. Porcine cornea often is used as a model in preclinical studies because of its similarity to man and its availability. METHODS: The important physical parameters for biomechanical deformation, heat conduction, and collagen denaturation kinetics have been determined for porcine cornea. Experimental methods include densitometry, calorimetry, turbidimetry, tensile tests, stress relaxation, and hydrothermal isometric tension measurements. RESULTS: The density of porcine cornea was measured as p = 1062+/-5 kg/m3, the heat capacity gave c = 3.74+/-0.05 J/gK. The stress-strain relation for corneal strips is represented by a third order approximation where the secant modulus yields about Esec approximately equal to 0.4 MPa for small strains less than 2%. The normalized stress relaxation is described by an exponential fit over time. The denaturation process of cornea is characterized by specific temperatures which can be related to the change of the mechanical properties. Denaturation kinetics are described according to the model of Arrhenius yielding the activation energy deltaEa = 106 kJ/mol and the phase transition entropy deltaS = 39 J/(mol x K). CONCLUSIONS: The established set of parameters characterizes the porcine cornea in a reliable way that creates a basis for corneal models. It furthermore gives direct hints of how to treat cornea in certain refractive techniques.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Mechanisms of Pulsed Laser Ablation of Biological Tissues
Vogel, A., & Venugopalan, V. (2003) · Chemical Reviews · doi:10.1021/cr010379n · Cited by 1,918
BISCHOF, J. C., & HE, X. (2006) · Annals of the New York Academy of Sciences · doi:10.1196/annals.1363.003 · Cited by 351
Biomechanical properties of human and porcine corneas
Elsheikh, A., Alhasso, D., & Rama, P. (2008) · Experimental Eye Research · doi:10.1016/j.exer.2008.02.006 · Cited by 253
Full-field deformation of bovine cornea under constrained inflation conditions
Boyce, B. L., Grazier, J. M., Jones, R. E., & Nguyen, T. D. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.06.011 · Cited by 191
Metadata
- Authors
- Kampmeier, J., Radt, B., Birngruber, R., & Brinkmann, R.
- Venue
- Cornea
- Published
- 2000-05
- Volume
- 19
- Issue
- 3
- Pages
- 355-363
- ISSN
- 0277-3740 (ISSN-L)
- OpenAlex
- W2002124945
- Cited by
- 210
- References
- 0
- FWCI
- 4.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Thermal and Biomechanical Parameters of Porcine Cornea. https://app.cochat.ai/papers/10.1097/00003226-200005000-00020
- The paper
- Kampmeier, J., Radt, B., Birngruber, R., & Brinkmann, R. (2000). Thermal and Biomechanical Parameters of Porcine Cornea. Cornea. https://doi.org/10.1097/00003226-200005000-00020
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.