Thermal and Biomechanical Parameters of Porcine Cornea
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
PURPOSE: New methods in refractive surgery require a considerable understanding of the material "cornea" and are often studied by theoretical modeling in order to gain insight into the procedure and an optimized approach to the technique. The quality of these models is highly dependent on the preciseness of its input parameters. Porcine cornea often is used as a model in preclinical studies because of its similarity to man and its availability. METHODS: The important physical parameters for biomechanical deformation, heat conduction, and collagen denaturation kinetics have been determined for porcine cornea. Experimental methods include densitometry, calorimetry, turbidimetry, tensile tests, stress relaxation, and hydrothermal isometric tension measurements. RESULTS: The density of porcine cornea was measured as p = 1062+/-5 kg/m3, the heat capacity gave c = 3.74+/-0.05 J/gK. The stress-strain relation for corneal strips is represented by a third order approximation where the secant modulus yields about Esec approximately equal to 0.4 MPa for small strains less than 2%. The normalized stress relaxation is described by an exponential fit over time. The denaturation process of cornea is characterized by specific temperatures which can be related to the change of the mechanical properties. Denaturation kinetics are described according to the model of Arrhenius yielding the activation energy deltaEa = 106 kJ/mol and the phase transition entropy deltaS = 39 J/(mol x K). CONCLUSIONS: The established set of parameters characterizes the porcine cornea in a reliable way that creates a basis for corneal models. It furthermore gives direct hints of how to treat cornea in certain refractive techniques.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Photorefractive keratectomy: A technique for laser refractive surgery
Munnerlyn, C. R., Koons, S. J., & Marshall, J. (1988) · Journal of Cataract and Refractive Surgery · doi:10.1016/s0886-3350(88)80063-4 · Cited by 763
PATHOLOGIC ANALYSIS OF PHOTOTHERMAL AND PHOTOMECHANICAL EFFECTS OF LASER–TISSUE INTERACTIONS
Thomsen, S. (1991) · Photochemistry and Photobiology · doi:10.1111/j.1751-1097.1991.tb09897.x · Cited by 585
Strip Extensiometry for Comparison of the Mechanical Response of Bovine, Rabbit, and Human Corneas
Hoeltzel, D. A., Altman, P., Buzard, K., & Choe, K.-I. (1992) · Journal of Biomechanical Engineering · doi:10.1115/1.2891373 · Cited by 263
An ultrasound indentation system for biomechanical properties assessment of soft tissues in-vivo
Zheng, Y.-P., & Mak, A. F. T. (1996) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.532125 · Cited by 218
Effect of the dynamic optical properties of water on midinfrared laser ablation
Walsh, J. T., & Cummings, J. P. (1994) · Lasers in Surgery and Medicine · doi:10.1002/lsm.1900150310 · Cited by 147
Isometric Tensions Developed During the Hydrothermal Swelling of Rat Skin
Allain, J., Lous, M. L., Cohen-Solal, L., Bazin, S., & MAROTEAUX, P. (1980) · Connective Tissue Research · doi:10.3109/03008208009152104 · Cited by 137 · cited 2×
“Another point to mention is the age dependency of collagen denaturation which was found, for example, in HIT measurements of rat skin by Allain.(51) In these experiments, the maximum of tissue contraction shifted to higher temperatures in correlation to age.”
BackgroundRheology of the cornea: Experimental techniques and results
Nyquist, G. W. (1968) · Experimental Eye Research · doi:10.1016/s0014-4835(68)80064-8 · Cited by 112
Introduction to Biomechanics of the Cornea
Buzard, K. A. (1992) · Journal of Refractive Surgery · doi:10.3928/1081-597x-19920301-07 · Cited by 108
A multi-sample denaturation temperature tester for collagenous biomaterials
Lee, J.-H., Pereira, C. A., Abdulla, D., Naimark, W. A., & Crawford, I. (1995) · Medical Engineering & Physics · doi:10.1016/1350-4533(95)91882-h · Cited by 99
A Poroelastic Finite Element Formulation Including Transport and Swelling in Soft Tissue Structures
SIMON, B. R., Liable, J. P., Pflaster, D., Yuan, Y., & Krag, M. H. (1996) · Journal of Biomechanical Engineering · doi:10.1115/1.2795941 · Cited by 97
Comparative studies of collagens in normal and keratoconus corneas
Zimmermann, D. R., Fischer, R. W., Winterhalter, K. H., Witmer, R., & Vaughan, L. (1988) · Experimental Eye Research · doi:10.1016/s0014-4835(88)80031-9 · Cited by 95 · cited 1×
“mal weight and is filled with the filamentous collagen type VI, proteoglycans, and other proteins and minerals.(8)”
BackgroundLous, M. L., Flandin, F., Herbage, D., & Allain, J. (1982) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/0304-4165(82)90182-9 · Cited by 85
Computer Simulation of Arcuate Keratotomy for Astigmatism
Hanna, K. D., Jouve, F., Waring, G. O., & Ciarlet, P. G. (1992) · Journal of Refractive Surgery · doi:10.3928/1081-597x-19920301-11 · Cited by 51
Comparative rheology of cornea
Loewenstein, M. A., & Bettelheim, F. A. (1976) · Comparative Biochemistry and Physiology Part A Physiology · doi:10.1016/0300-9629(76)90062-1 · Cited by 4
Cited by
Mechanisms of Pulsed Laser Ablation of Biological Tissues
Vogel, A., & Venugopalan, V. (2003) · Chemical Reviews · doi:10.1021/cr010379n · Cited by 1,918
Wollensak, G., Spoerl, E., & Seiler, T. (2003) · Journal of Cataract and Refractive Surgery · doi:10.1016/s0886-3350(03)00407-3 · Cited by 1,024
Assessment of Corneal Biomechanical Properties and Their Variation with Age
Elsheikh, A., Wang, D., Brown, M., Rama, P., Campanelli, M., & Pye, D. (2007) · Current Eye Research · doi:10.1080/02713680601077145 · Cited by 394
BISCHOF, J. C., & HE, X. (2006) · Annals of the New York Academy of Sciences · doi:10.1196/annals.1363.003 · Cited by 351
Biomechanical properties of human and porcine corneas
Elsheikh, A., Alhasso, D., & Rama, P. (2008) · Experimental Eye Research · doi:10.1016/j.exer.2008.02.006 · Cited by 253
Metadata
- Authors
- Kampmeier, J., Radt, B., Birngruber, R., & Brinkmann, R.
- Venue
- Cornea
- Published
- 2000-05
- Volume
- 19
- Issue
- 3
- Pages
- 355-363
- ISSN
- 0277-3740 (ISSN-L)
- OpenAlex
- W2002124945
- Cited by
- 210
- References
- 14
- FWCI
- 4.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.