The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Between-Eye Asymmetry in Keratoconus
Abstract
PURPOSE: To report baseline differences between eyes on key variables in the Collaborative Longitudinal Evaluation of Keratoconus (CLEK) Study cohort compared with a retrospectively assembled group of myopic contact lens wearers without ocular disease. METHODS: A total of 1,079 keratoconus patients who had not undergone a penetrating keratoplasty in either eye before their baseline visit were enrolled and examined at baseline. Records from 330 contact lens-wearing myopes were reviewed. Corneal curvature (keratometry), visual acuity, refractive error (manifest refraction), and corneal scarring were measured. RESULTS: The mean differences between keratoconic eyes are as follows (better eye-worse eye for each variable, separately). Flat keratometry: -3.59 +/-4.46 D and steep keratometry: -4.35 +/-4.41 D; high-contrast best-corrected visual acuity: 7.30 +/-6.83 letters; low-contrast best-corrected visual acuity: 8.53 +/-7.51 letters; high-contrast entrance visual acuity: 9.03 +/-8.40 letters; low-contrast entrance visual acuity: 9.43 +/-7.88 letters; spherical equivalent refractive error: 3.15 +/-3.84 D; and refractive cylinder power 1.55 +/-1.42 D. Twenty-one percent of the keratoconus patients had corneal scarring in only one eye. There is an association between patient-reported unilateral eye rubbing and greater asymmetry in corneal curvature, and between a history of unilateral eye trauma and greater asymmetry in corneal curvature and refractive error, with the rubbed/traumatized eye being the steeper eye most of the time. CONCLUSIONS: Keratoconus is asymmetric in the CLEK Study sample.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intraclass correlations: Uses in assessing rater reliability.
Shrout, P. E., & Fleiss, J. L. (1979) · Psychological Bulletin · doi:10.1037/0033-2909.86.2.420 · Cited by 24,532
Cited by
Risk Assessment for Ectasia after Corneal Refractive Surgery
Randleman, J. B., Woodward, M., Lynn, M. J., & Stulting, R. D. (2008) · Ophthalmology · doi:10.1016/j.ophtha.2007.03.073 · Cited by 739
Keratoconus: An updated review
Santodomingo-Rubido, J., Carracedo, G., Suzaki, A., Villa-Collar, C., Vincent, S. J., & Wolffsohn, J. S. (2022) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2021.101559 · Cited by 723
The Genetic and Environmental Factors for Keratoconus
Gordon-Shaag, A., Millodot, M., Shneor, E., & Liu, Y. (2015) · BioMed Research International · doi:10.1155/2015/795738 · Cited by 428
Inflammatory Molecules in the Tears of Patients with Keratoconus
LEMA, I., & DURAN, J. (2005) · Ophthalmology · doi:10.1016/j.ophtha.2004.11.050 · Cited by 394
Automated Decision Tree Classification of Corneal Shape
Twa, M. D., Parthasarathy, S., Roberts, C., Mahmoud, A. M., Raasch, T. W., & Bullimore, M. A. (2005) · Optometry and Vision Science · doi:10.1097/01.opx.0000192350.01045.6f · Cited by 108
Self-citation
Metadata
- Authors
- Zadnik, K., Steger-May, K., Fink, B. A., Joslin, C. E., Nichols, J. J., Rosenstiel, C. E., Tyler, J. A., Yu, J. A., Raasch, T. W., & Schechtman, K. B.
- Venue
- Cornea
- Published
- 2002-10
- Volume
- 21
- Issue
- 7
- Pages
- 671-679
- ISSN
- 0277-3740 (ISSN-L)
- OpenAlex
- W2101687054
- Cited by
- 193
- References
- 1
- FWCI
- 2.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Between-Eye Asymmetry in Keratoconus. https://app.cochat.ai/papers/10.1097/00003226-200210000-00008
- The paper
- Zadnik, K., Steger-May, K., Fink, B. A., Joslin, C. E., Nichols, J. J., Rosenstiel, C. E., Tyler, J. A., Yu, J. A., Raasch, T. W., & Schechtman, K. B. (2002). Between-Eye Asymmetry in Keratoconus. Cornea. https://doi.org/10.1097/00003226-200210000-00008
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.