The DOI matches its Crossref record.
Noninvasive cerebral optical spectroscopy for monitoring cerebral oxygen delivery and hemodynamics
Abstract
OBJECTIVE: To present an algorithm for noninvasive measurement of cerebral oxygen saturation (cerebral oximetry) and cerebral hemodynamics with near infrared spectroscopy. DESIGN: In vitro correlation of oximetry measurements with reference measurements; illustrative cases of hemodynamic and oximetric recordings. SETTING: Tertiary care neuroscience ICU. PATIENTS: Brain-injured patients with a prolonged, decreased level of consciousness chosen as illustrative examples. INTERVENTIONS: Two-channel multiple wavelength diffuse infrared transmission spectroscopy was interfaced with the scalp using adhesive. Transmission data were collected with gross superficial-to-deep spatial resolution. Saturation calculation based on the deep signal was observed longitudinally in the patient. With the same technology, arterial input and cerebral response functions, generated by iv tracer bolus, were deconvoluted to measure mean cerebral transit time. MEASUREMENTS AND MAIN RESULTS: A positive linear regression fit between diffuse transmission oximetry and measured blood oxygen saturation over the range 23% to 99% (r2 = .98, p less than .001) was noted. CONCLUSIONS: The approach used overcomes previously identified difficulties with cerebral oximetry, and demonstrates excellent in vitro correlation. The technique can be performed clinically without difficulty. A simultaneous measure of mean cortical transit time is possible.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Non-invasive optical spectroscopy and imaging of human brain function
Villringer, A., & Chance, B. (1997) · Trends in Neurosciences · doi:10.1016/s0166-2236(97)01132-6 · Cited by 1,618
Villringer, A., Planck, J., Hock, C., Schleinkofer, L., & Dirnagl, U. (1993) · Neuroscience Letters · doi:10.1016/0304-3940(93)90181-j · Cited by 1,119
Near-infrared spectroscopy as an index of brain and tissue oxygenation
Murkin, J. M., & Arango, M. (2009) · British Journal of Anaesthesia · doi:10.1093/bja/aep299 · Cited by 877
Quantification in tissue near–infrared spectroscopy
Delpy, D. T., & Cope, M. (1997) · Philosophical Transactions of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rstb.1997.0046 · Cited by 507
Functional near-infrared spectroscopy: current status and future prospects
Hoshi, Y. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2804911 · Cited by 468
Metadata
- Authors
- MCCORMICK, P. W., STEWART, M., GOETTING, M. G., DUJOVNY, M., LEWIS, G., & AUSMAN, J. I.
- Venue
- Critical Care Medicine
- Published
- 1991-01
- Volume
- 19
- Issue
- 1
- Pages
- 89-97
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W2025492305
- Cited by
- 322
- References
- 0
- FWCI
- 16.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Noninvasive cerebral optical spectroscopy for monitoring cerebral oxygen delivery and hemodynamics. https://app.cochat.ai/papers/10.1097/00003246-199101000-00020
- The paper
- MCCORMICK, P. W., STEWART, M., GOETTING, M. G., DUJOVNY, M., LEWIS, G., & AUSMAN, J. I. (1991). Noninvasive cerebral optical spectroscopy for monitoring cerebral oxygen delivery and hemodynamics. Critical Care Medicine. https://doi.org/10.1097/00003246-199101000-00020
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.