Anatomical variations of internal jugular vein location: Impact on central venous access
The DOI matches its Crossref record.
Abstract
OBJECTIVE: To evaluate whether underlying anatomical variations in the position of the internal jugular vein may account for difficulty in obtaining central venous access in individual patients. DESIGN: Consecutive series. SETTING: Cardiac catheterization laboratory, coronary care unit, and ICU. PATIENTS: Two hundred patients (52 +/- 7 yrs, 147 males) who were undergoing internal jugular vein cannulation for hemodynamic monitoring or endomyocardial biopsy. INTERVENTION: The internal jugular vein and carotid artery were visualized with two-dimensional ultrasound and their position was compared with their projected location from external landmarks. RESULTS: In 183 (92%) patients, the position of the internal jugular vein was lateral and anterior to the carotid artery and increased in diameter during a Valsalva maneuver. In five (2.5%) patients, the internal jugular vein was not visualized and was probably thrombosed, as the internal jugular vein was normal on the other side. In six (3%) patients, the internal jugular vein was unusually small and did not increase in diameter during the Valsalva maneuver. In two (1%) patients, the internal jugular vein was positioned greater than 1 cm lateral to the carotid artery. Four (2%) patients had a medially positioned internal jugular vein overlying the carotid artery. In 5.5% of the patients, the position of the internal jugular vein was outside the path that had been predicted by the external landmarks. CONCLUSIONS: These findings suggest that anatomical variation may partly account for the inability to cannulate the internal jugular vein in certain patients. In these cases, ultrasound examination quickly establishes the position of the internal jugular vein and may allow for easy and rapid access.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ultrasound guidance for placement of central venous catheters: A meta-analysis of the literature
Randolph, A. G., Cook, D. J., Gonzales, C. A., & Pribble, C. G. (1996) · Critical Care Medicine · doi:10.1097/00003246-199612000-00020 · Cited by 852
International evidence-based recommendations on ultrasound-guided vascular access
Lamperti, M., Bodenham, A. R., Pittiruti, M., Blaivas, M., Augoustides, J. G., Elbarbary, M., Pirotte, T., Karakitsos, D., LeDonne, J., Doniger, S., et al. (2012) · Intensive Care Medicine · doi:10.1007/s00134-012-2597-x · Cited by 834
Saugel, B., Scheeren, T. W. L., & Teboul, J.-L. (2017) · Critical Care · doi:10.1186/s13054-017-1814-y · Cited by 481
Ultrasound guidance versus anatomical landmarks for internal jugular vein catheterization
Brass, P., Hellmich, M., Kolodziej, L., Schick, G., & Smith, A. F. (2015) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd006962.pub2 · Cited by 476
Troianos, C. A., Hartman, G. S., Glas, K. E., Skubas, N. J., Eberhardt, R. T., Walker, J. D., & Reeves, S. T. (2011) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2011.09.021 · Cited by 420
Milling, T. J., Rose, J., Briggs, W. M., Birkhahn, R., Gaeta, T. J., Bove, J. J., & Melniker, L. A. (2005) · Critical Care Medicine · doi:10.1097/01.ccm.0000171533.92856.e5 · Cited by 334
Complications of Central Venous Catheterization
Kusminsky, R. E. (2007) · Journal of the American College of Surgeons · doi:10.1016/j.jamcollsurg.2007.01.039 · Cited by 330
Verghese, S. T., McGill, W. A., Patel, R. I., Sell, J. E., Midgley, F. M., & Ruttimann, U. E. (1999) · Anesthesiology · doi:10.1097/00000542-199907000-00013 · Cited by 324
Troianos, C. A., Hartman, G. S., Glas, K. E., Skubas, N. J., Eberhardt, R. T., Walker, J. D., & Reeves, S. T. (2012) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e3182407cd8 · Cited by 321
Ultrasound guidance versus anatomical landmarks for subclavian or femoral vein catheterization
Brass, P., Hellmich, M., Kolodziej, L., Schick, G., & Smith, A. F. (2015) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd011447 · Cited by 320
Franco‐Sadud, R., Schnobrich, D., Mathews, B. K., Candotti, C., Abdel‐Ghani, S., Perez, M. G., Rodgers, S. C., Mader, M. J., Haro, E. K., Dancel, R., et al. (2019) · Journal of Hospital Medicine · doi:10.12788/jhm.3287 · Cited by 260
Internal Jugular Vein and Carotid Artery Anatomic Relation as Determined by Ultrasonography
Troianos, C. A., Kuwik, R. J., Pasqual, J. R., Lim, A. J., & Odasso, D. P. (1996) · Anesthesiology · doi:10.1097/00000542-199607000-00007 · Cited by 232
Comparison of three techniques for internal jugular vein cannulation in infants
Verghese, S. T., McGill, W. A., Patel, R. I., Sell, J. E., Midgley, F. M., & Ruttimann, U. E. (2000) · Pediatric Anesthesia · doi:10.1046/j.1460-9592.2000.00554.x · Cited by 165
Metadata
- Authors
- DENYS, B. G., & URETSKY, B. F.
- Venue
- Critical Care Medicine
- Published
- 1991-12
- Volume
- 19
- Issue
- 12
- Pages
- 1516-1519
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W1963754266
- Cited by
- 302
- References
- 0
- FWCI
- 7.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.